AQUALABO PF-CAP-C-00141 Optod Numerical Sensor

AQUALABO-PF-CAP-C-00141-Optod-Numerical-Sensor-

Umum
Kanggo njaga lan mesthekake supaya sensor OPTOD Plastik bisa digunakake kanthi apik, pangguna kudu tundhuk karo pancegahan lan bebaya safety sing ditampilake ing manual iki.

Majelis lan aktivasi:

  • Majelis, sambungan listrik, aktivasi, operasi lan pangopènan sistem pangukuran mung kudu ditindakake dening personel spesialis sing sah dening pangguna fasilitas kasebut.
  • Personel sing dilatih kudu ngerti lan tundhuk karo pandhuan ing manual iki.
  • Priksa manawa sumber daya tundhuk karo spesifikasi sadurunge nyambungake piranti.
  • Saklar daya kanthi label kanthi cetha kudu dipasang ing cedhak piranti.
  • Priksa kabeh sambungan sadurunge nguripake daya.
  • Aja nyoba nggunakake peralatan sing rusak: bisa uga ana bebaya lan kudu dilabeli salah.
  • Ndandani mung kudu ditindakake dening pabrikan utawa departemen layanan sawise-sales AQUALABO.

Tandha ing awak sensor:
Tandha ing awak sensor nuduhake nomer serial sensor (kanggo traceability) lan LOGO CE.AQUALABO-PF-CAP-C-00141-Optod-Numerical-Sensor-fig-1

1 Datamatrix (ngemot nomer seri)
2 Sensor OPTOD nomer seri: SN-PODOJ-YYYY

X: versi

YYYYY : nomer

3 tandha CE

Karakteristik

Karakteristik teknis.
Karakteristik teknis bisa diowahi tanpa kabar sadurunge.

ngukur
Prinsip ngukur Ukuran optik kanthi luminescence
 

Rentang ukuran

0,00 nganti 20,00 mg / L

0,00 nganti 20,00 ppm

0-200%

Resolusi 0,01
 

Akurasi

+/- 0,1 mg/L

+/- 0,1 ppm

+/- 1 % (+/- 5% yen Gangguan EMI luwih saka 10V/m)

Sensor kudu dilebokake kanthi lengkap kanggo njamin presisi maksimal

Watesan deteksi 0.7 %
Watesan kuantitas 2.2 %
Pangulangan (100% Sat) 0.2 %
Keamanan > 0.99
Wektu nanggepi 0-> 100%; T90<40s

100 -> 0%; T90<65 s

Frekuensi ukuran sing disaranake > 5 s
Aliran banyu ora perlu gerakan kanggo pangukuran
Kompensasi suhu Liwat NTC
Suhu 0.00-50.00 °C

Akurasi: +/- 0.5 °C

Suhu stoking - 10 ° C nganti + 60 ° C
Sensor
ukuran Versi standar: Diameter: 27 mm; dawa: 143 mm

Versi sing luwih dawa: Diameter: 27 mm ; dawa: 166 mm

Bobot 300 g (sensor + kabel 3 m)
 

 

Bahan wetted

POMC ireng, PVC

 

Kabel: jaket polyurethane Kelenjar uap: Poliamida

 

Tambalan nganggo bahan aktif (ireng) - DO DISK : Silikon isolasi optik

 

 

DO disk

Ora ana sensitivitas silang karo:

pH 1 – 14; CO2, H2S, SO2

 

Sensitivitas silang kanggo pelarut Organik, kayata aseton, toluene, kloroform utawa metilen klorida

Gas klorin

Tekanan maksimum 5 bar
Klasifikasi IP IP68
Sambungan 9 konektor waja, jaket polyurethane, tanpa kabel
Kabel Sensor Kab Standar: 3, 7 lan 15 m (dawa liyane ing panyuwunan).

100 m Maks.

kepatuhan CE.
Miturut artikel 11 saka arahan 89 / 336 / EEC babagan kompatibilitas elektromagnetik.
Kita nyatakake yen sensor digital saka sawetara DIGISENS sensor OPTOD diuji lan diumumake selaras karo standar Eropa:

Tes standar: NF EN IEC 61326-1: 2021-06
NF EN IEC 61326-1 (2021-06)
Peralatan listrik kanggo pangukuran, kontrol lan panggunaan laboratorium - Keperluan EMC -
Bagean 1: Persyaratan umum.
2.2. REFERENSI NORMATIF [1] NF EN 55011: 2016-06 +/A1: 2017-06 +/A2: 2021-04
Peralatan industri, ilmiah lan medis - Ciri gangguan frekuensi radio - Watesan lan cara pangukuran.
Kekebalan: Kekebalan radiasi EN 61000-4-3 Lingkungan industri - Kriteria A
TS EN 61000-4-2 Lingkungan industri - Kriteria B
Mode umum RF EN 61000-4-6 Lingkungan industri - Kriteria A
Surge EN 61000-4-5 Lingkungan industri - Kriteria B
Cepet Transients EN 61000-4-4 Lingkungan industri - Kriteria B
Gangguan: EN 55011B
Emisi radiasi - EN 55011 Grup 1 - Kelas A
Emisi sing ditindakake - EN 55011 Grup 1 - Kelas A

Katrangan.

Produk liwatview
Sensor oksigen terlarut OPTOD ngetrapake teknologi pangukuran optik berbasis luminescence lan ngukur kanthi andal lan akurat tanpa mbutuhake kalibrasi. Tanpa bahan bakar utawa pangopènan sing dibutuhake, sensor OPTOD menehi bali langsung kanggo investasi kasebut. Mung intervensi sing dibutuhake yaiku ngganti disk DO saben rong taun. Amarga ora nganggo oksigen, sensor OPTOD bisa digunakake ing kabeh media; sanajan ana aliran banyu banget banget.

Sensor OPTOD nawakake advan ing ngisor ikitages: 

  • Biaya operasi murah amarga kerja pangopènan suda (ora ana owah-owahan elektrolit)
  • Interval kalibrasi sing luwih gedhe amarga prilaku drift sing kurang
  • Ora polarisasi voltage dibutuhake
  • Akurasi pangukuran sing dhuwur, sanajan kanggo konsentrasi sing sithik
  • Wektu nanggepi cepet
  • Ora ana aliran mlebu minimal (ora ana konsumsi oksigen);

Sensor kasebut nduweni kekebalan interferensi sing apik banget amarga wis terintegrasiamplifier lan pangolahan sinyal digital. Nilai sing diukur kanggo oksigen terlarut kanthi otomatis menehi ganti rugi kanthi suhu, tekanan udara, lan salinitas (isi uyah), lan ditransfer tanpa gangguan menyang unit tampilan lan pengontrol sing disambungake liwat antarmuka digital. Tutup membran gampang diganti, tegese sensor gampang banget dijaga. Data kalibrasi saiki disimpen langsung ing elektronik sensor. Akibaté, fungsi Plug and Play sistem diaktifake tanpa kalibrasi ulang. Sensor uga kalebu buku log ngemot sepuluh kalibrasi sukses pungkasan ing wangun buffer ring.

Aplikasi
Sensor plastik sing kompak lan kuwat banget cocog karo area aplikasi khas ing ngisor iki:

  • Pemantauan banyu permukaan, banyu pesisir, akuarium,
  • Budidaya iwak: kurungan tertutup, lepas pantai,
  • Budidaya iwak, budidaya,

Konstruksi lan dimensi.AQUALABO-PF-CAP-C-00141-Optod-Numerical-Sensor-fig-2

  1. Saringan pelindung (2 versi: standar lan luwih dawa)
  2. DODISK ing dhukungan plastik
  3. DODISK Gasket Kab
  4. Gasket
  5. Awak sensor karo bagean elektronik
  6. Kelenjar kabel
  7. Kabel sambungan sing disambungake kanthi amanAQUALABO-PF-CAP-C-00141-Optod-Numerical-Sensor-fig-3
Komunikasi.

Modbus RTU ndhaftar.
Protokol link kudu cocog karo MODBUS RTU. Deleng dokumen:

  • Modbus_over_serial_line_V1_02.pdf
  • Modbus_Application_Protocol_V1_1a.pdf
  • Memori Modbus kanggo Sensor digital PONSEL:
    SENSOR_TramesCom_xxx_UK.xls (waca www.aqualabo.fr)
    Pesawat memori Modbus podho rupo kanggo saben parameter saka Sensor.
    Protokol Modbus kanggo Sensor ngijini sampeyan kanggo ngukur parameter (+ suhu) saka Sensor lan kanggo calibrate parameter (+ suhu). Kajaba iku, ana sawetara fungsi kayata:
  • Pilih nilai rata-rata
  • Maca katrangan Sensor
  •  Bali menyang koefisien standar
  • Ngowahi alamat Sensor
  • Informasi babagan langkah-langkah sing ditindakake (Out Of Specification measures, measures in progress, etc.).
  • Tanggal lan jeneng operator sing nindakake kalibrasi
  • lsp.
    Kanggo entuk informasi luwih lengkap babagan protokol Modbus PONSEL sing mbukak, bukak versi pungkasan saka dokumen ing ngisor iki:
  • pdf ing file: Modbus_SpecificationsVxxx-EN
  • unggulan file: Sensor digital Frame_XXX_UK

Rangka SDI 12.
Dhaptar register SDI12 kasedhiya kanggo komunikasi jaringan. Waca www.aqualabo.fr kanggo informasi luwih lengkap.

Ganti rugi
Pengaruh ing pangukuran.
Pangukuran oksigen gumantung ing parameter:

  • Suhu medium pangukuran
  • Tekanan udara (tekanan atmosfer)
  • Salinitas medium pangukuran
    Tingkat kelarutan oksigen ing banyu gumantung ing suhu, salinitas, lan
    tekanan udara. Ketergantungan iki disimpen ing elektronik pangukuran sensor ing
    wangun fungsi. Mulane sensor bisa nemtokake konsentrasi oksigen saka medium pangukuran, supaya digital ngirim faktor pengaruh ing ndhuwur, ing wangun menehi ganti rugi, kanggo pemancar / controller.

Kompensasi suhu.
Kompensasi suhu otomatis lan dikelola langsung dening sensor liwat sensor suhu terintegrasi (NTC).

Tekanan atmosfer.
Kanthi cara kalibrasi sing paling kerep digunakake - kalibrasi nilai pungkasan sensor ing banyu
hawa jenuh uap - tekanan udara kudu dianggep.
Kanggo tujuan iki, tekanan udara bisa, contoneample, ditularaké kanggo sensor dening cara terminal Panjenengan, ngendi iku disimpen.
Kanthi gawan, nilai atmosfer sing digunakake kanggo ganti rugi yaiku 1013 hPa.

Salinitas.
Nilai salinitas medium pangukuran bisa dikirim menyang sensor liwat terminal sampeyan.
Kanthi gawan, nilai salinitas sing digunakake kanggo kompensasi yaiku 0 g / Kg.

Samptingkat ling
Sensor oksigen optik ora nindakake pangukuran terus-terusan. Kanggo ngluwihi umur operasi membran optik, interval pangukuran bisa disetel menyang nilai sing luwih dhuwur tinimbang 10 detik.

Instalasi.

Pilihan instalasi sensor
Kanggo panginstalan sensor ing kondisi kecemplung utawa selipan ing pipa, disaranake nggunakake aksesoris sing diadaptasi lan diusulake dening AQUALABO.

Aksesoris kanggo instalasi kecemplung.
Ing kondisi kecemplung, perlu kanggo njaga sensor dening awak lan ora ninggalake sensor dilereni soko tugas dening kabel ing risiko ngrusak sensor AQUALABO ngusulake sawetara utawa kutub (versi cendhak lan dawa) kanggo nginstal sensor ing cekungan mbukak. Bisa dipanggonke jarak owahan saka pinggir cekungan karo krenjang dilereni soko tugas ing chain, kanggo Example. Wigati ing ngisor iki nalika ngrancang setelan:

  • Pas kudu gampang diakses kanggo ngidini sensor utawa pas dhewe kanggo maintained lan di resiki ajeg
  • Aja ngidini fitting (lan kanthi mangkono uga sensor) kanggo ngayun menyang pinggir cekungan
  • Nalika nggarap sistem sing nglibatake tekanan lan / utawa suhu, priksa manawa pas lan sensor nyukupi kabeh syarat sing cocog
  • Perancang sistem kudu mriksa manawa bahan ing pas lan sensor cocog kanggo pangukuran (kompatibilitas kimia, umpamane)
    Bahan PVC
    Suhu sing bisa ditampa 0 nganti 60 °C
    Tekanan maks. 5 bar
Tiang cendhakAQUALABO-PF-CAP-C-00141-Optod-Numerical-Sensor-fig-4

Kutub cendhak kasedhiya ing 2 versi:
versi karo rana elbowed. Nozzle dhukungan kalebu ing tawaran.

 

PF-ACC-C-00486

90 ° elbow short perch FOR PLASTIK OPTOD

SENSOR (1495 mm, RANA SIKU)

versi karo rana kanggo soyo tambah karo chain, nozzle support klebu ing nawarake.

 

PF-ACC-C-00487

90 ° elbow short perch FOR PLASTIK OPTOD

SENSOR (1550 mm, RING RANA)

Cagak dawa

Cagak dawa kasedhiya ing versi sikut, kanggo instalasi ing cekungan aerasi, lan lurus, kanggo aplikasi ing saluran sing mbukak. Saben kutub dilengkapi rana elbowed lan sambungan anti banyu. Sisih ngisor kalebu muncung sing dicocogake karo sensor sing njamin dhukungan mekanik.AQUALABO-PF-CAP-C-00141-Optod-Numerical-Sensor-fig-5

Tiang siku karo rana siku

 

PF-ACC-C-00484

90 ° ElBOW LONG PERCH FOR PLASTIK OPTOD

SENSOR (2955 mm, RANA SIKU)

Cagak dawa lurus kanthi rana elbowed

 

PF-ACC-C-00485

PERCH PANJANG LURUS UNTUK SENSOR OPTOD PLASTIK (2745 mm, SIKU)

rana)

Aksesori pemasangan kanggo kutub.
Unsur fiksasi kanggo kutub fleksibel lan ditliti khusus kanggo adaptasi karo konfigurasi perakitan sing beda.AQUALABO-PF-CAP-C-00141-Optod-Numerical-Sensor-fig-6

- Pole kit fiksasi

 

NC-ACC-C-00009

POLE FIXATION KIT FOR

SENSOR NUMERIK (NENG DINDING RENDAH)

 

NC-ACC-C-00010

POLE FIXATION KIT FOR

SENSOR NUMERIK (ON LIFE LINE)

 

NC-ACC-C-00011

POLE FIXATION KIT FOR

SENSOR NUMERIKAL (NUNG AXIS VERTIKAL)

 

PF-ACC-C-00272

AXIS VERTIKAL FOR NUMERICAL SENSOR POLE

(Kanggo DIBUAT ING LEMAH)

AQUALABO-PF-CAP-C-00141-Optod-Numerical-Sensor-fig-7

Kit aksesoris kanggo perakitan kutub kanthi ranté.

NC-ACC-C-00012 KIT FIXATION POLE CENDEK UNTUK SENSOR NUMERIKAL (ING DINDING RENDAH)
NC-ACC-C-00013  

KIT FIXATION POLE CENDEK UNTUK SENSOR NUMERIK (ON LIFE LINE)

NC-ACC-C-00014 KIT FIXATION POLE CENDEK UNTUK SENSOR NUMERIKAL (NOT AXIS VERTIKAL)

Sisipan ing kutub.
Sensor dipasang ing pas sing cocog kaya sing diterangake ing ngisor iki, nggunakake wadhah sensor, sing bisa digunakake kanggo kutub cendhak lan dawa:AQUALABO-PF-CAP-C-00141-Optod-Numerical-Sensor-fig-8

  1. Copot tutup protèktif ing sensor lan lebokake sensor (2) menyang muncung (1) nganti mandeg.
  2. Lebokake kabel sensor menyang pipa pas (6) lan rampung feed liwat.AQUALABO-PF-CAP-C-00141-Optod-Numerical-Sensor-fig-9
  3. Sekrup wadhah sensor nganggo nut union (5) menyang pipa pas (6) lan kenceng nganti kenceng tangan.
 Sambungan listrik.

Sensor bisa ngirim ing kabel telanjang versi ing 3, 7, 15 m utawa ing dawa liyane (nganti 100 m).

Komunikasi - Power supply
 

 

 

Antarmuka sinyal

Modbus 1 RS-485 utawa SDI-12 2,3

1,2 Sensor nanggapi ing Modbus / SDI12 kalebu nalika siyaga

3 Panggunaan lan sambungan bus SDI12 bisa nambah konsumsi daya siyaga * nganti 100uA gumantung saka tingkat garis (dhuwur utawa kurang). Konsumsi ora tambah yen garis SDI12 pedhot utawa dirilis menyang 0V

(Modbus RTU mung)

 

 

Sumber daya sensor (RS485 lan SDI12)

5 V 1,2 nganti 12 3,4 V DC (wektu pemanasan 100 ms)

1 4.5V minimal absolut kanthi kabel 1m, boot lan presisi ora dijamin ing 5V

2 Minimal voltage tundhuk losses kabel dawa-related

3 13V Absolute maksimum karo luwih saka 2 mA terus liwat konsumsi

4 Konsumsi liwat cilik antarane 12V lan 12.5V

Konsumsi Umum ing 5V (RS485) Dianjurake kanggo daya ultra-rendhek (1 ukuran nggunakake kurang saka 18 uWh)

Tundhuk modifikasi ing kasus bagean internal

évolusi

Siaga otomatis kurang saka 22 μA* (110 μW) Arus puncak maksimum: RS485 55 mA (2 ms)

Arus maksimum sajrone pangukuran: 19.5 mA (97.5 mW) Arus rata-rata sajrone pangukuran: 13 mA (65 mW)

Rata-rata saiki RS485 (1 mes. / detik): 3 mA (15 mW)

Konsumsi Umum ing 12V (RS485)

Aja ngluwihi 12.0V kanggo daya kurang (1 ukuran nggunakake kurang saka 43 uWh)

Tundhuk modifikasi ing kasus bagean internal

évolusi

Siaga otomatis kurang saka 25 μA* (300 μW) Arus puncak maksimum: 80 mA (2.5 ms)

Arus maksimum sajrone pangukuran: 20.5 mA (246 mW) Arus rata-rata sajrone pangukuran: 14 mA (168 mW)

Rata-rata saiki RS485 (1 mes. / detik): 3.2 mA (38.4 mW)

Konsumsi Umum ing 12.5V (RS485)

Ora dianjurake kanggo daya kurang

Tundhuk modifikasi ing kasus evolusi bagean internal

Siaga otomatis kurang saka 35 μA* (438 μW) maks. 1 mA maks. Arus puncak maksimum: 85 mA (3 ms)

Arus maksimum sajrone pangukuran: 21 mA (262.5 mW) Arus rata-rata sajrone pangukuran: 18 mA (225 mW)

Rata-rata saiki RS485 (1 mes. / detik): 3.2 mA (40 mW)

Konsumsi Umum ing 12V (SDI12)

Aja ngluwihi 12.0V kanggo daya kurang

Tundhuk modifikasi ing kasus evolusi bagean internal

Siaga otomatis kurang saka 25 μA* (300 μW) Arus puncak maksimum: 85 mA (3 ms)

Arus maksimum sajrone pangukuran: 27 mA (324 mW)

Arus rata-rata sajrone pangukuran: 18 mA (216 mW) Arus rata-rata

(1 ukuran/detik): 6 mA (72 mW)

Wiring diagramAQUALABO-PF-CAP-C-00141-Optod-Numerical-Sensor-fig-1
Dawane kabel nganti 15m Dawane kabel 15 nganti 100 meter Abang

wungu

Sumber Daya Kuning

Orange V+ pink

2 – Biru SDI-12

3 – Pasokan Daya Ireng V- 4 – Ijo B ” RS-485 ”

5 - Putih A "RS-485"

6 – Kabel tameng Green/kuning karo Power

pasokan V-

  1- Abang Sumber daya V+  
2 - Biru SDI-12
3 - Ireng Sumber daya V-
4 - Ijo B "RS-485"
5 - Putih A "RS-485"
6 –

Ijo/kuning

Perisai kabel kanthi catu daya V-

Cathetan:
Aja ngluwihi voltage saka 10VDC (rating maksimum absolut) ing garis komunikasi RS485, A utawa B, miturut paukuman karusakan ora bisa dibalèkaké saka komponen transceiver RS ​​485.
SDI-12: ngurmati voltagNilai e sing diterangake ing standar sing gegandhengan (nominal: 5 VDC)
Tansah nyambung lemah + tameng dhisik.

Wiwitan lan pangopènan.

Wiwitan wiwitan
Sawise sensor disambungake menyang terminal, sensor wis dienggoni ing aksesoris perakitan lan parameterization wis digawa metu ing unit tampilan, sensor siap kanggo wiwitan wiwitan.

Cathetan:
Kanggo pangukuran, sampeyan kudu ngilangi gelembung sing kepepet ing ngisor membran.
Anane klorin bakal ngrusak ukuran (overestimation tingkat oksigen terlarut).
Sajrone introduksi sensor ing lingkungan pangukuran, ngenteni stabilisasi suhu sensor sadurunge ngukur pangolahan.
Kanggo ngoptimalake fungsi probe sing lestari, disaranake sampeyan ngurmati frekuensi ukuran sing luwih dhuwur tinimbang 10 detik. .

Diwiwiti:
Copot tutup proteksi ireng (kanthi nyekeli sirah sensor mudhun lan uculake hood ing sisih tengen).
Sensor dikirim garing lan DODISK kudu dihidrasi maneh supaya langkah-langkah kasebut dioptimalake.
Sawise panyimpenan garing, rehydrate membran kanggo periode 12 jam (sewengi) ing banyu bening.

Kalibrasi
Sensor kasebut dikalibrasi miturut spesifikasi ing pabrik. Pabrikan ora nyaranake kalibrasi kajaba dibutuhake sacara periodik dening lembaga pangaturan. Yen kalibrasi dibutuhake, supaya sensor teka menyang keseimbangan karo proses sadurunge kalibrasi. Aja kalibrasi sensor ing persiyapan.
Sawise tutup membran diganti, kalibrasi kudu ditindakake.
Sampeyan uga dianjurake kanggo ngresiki sensor kanthi rutin (ndeleng pangopènan bab: 5.3);

 Kalibrasi ing 2 titik.
Kanthi kalibrasi rong titik, titik nol (0% - offset) lan kemiringan (100%) sensor dikalibrasi. Cara kalibrasi iki nyedhiyakake tingkat akurasi sing paling apik lan utamane dianjurake kanggo pangukuran konsentrasi oksigen cilik.
Iki ditindakake kaya ing ngisor iki:

Kalibrasi Offset:

  • Sensor sadurunge wis di resiki (kanggo ndeleng pangopènan bab 5.3) dicelupake ing larutan banyu-sulfit (konsentrasi sulfit <2 %) kanggo nemtokake titik nol (0 % saturasi). Nyampur solusi karo sensor supaya jenuh oksigen mudhun luwih cepet (Oksigen sing dipasang ing DODISK) kudu dikonsumsi),
    AWAS! Kerusakan membran sensor amarga bahan kimia.
    Membran sing rusak bisa nyebabake asil pangukuran sing salah.
    Membran sensor kudu ora kena kontak karo larutan sulfit luwih saka siji jam.
  • Ngumbah (kanthi banyu bening) lan garing sensor,
    Kalibrasi slope:
  • Kemiringan sensor ditemtokake kanthi posisi ing lingkungan jenuh oksigen (100 % saturasi.
    Kemiringan sensor dikalibrasi ngluwihi kahanan jenuh oksigen 100% sing ditemtokake. Negara iki bisa ditindakake kanthi rong cara:
  • Kanthi posisi sensor ing udara jenuh uap banyu (kanggo example, langsung liwat banyu
    lumahing).
  • Kanthi posisi sensor ing banyu jenuh udara (udhara diarahake liwat banyu nganti banyu
    wis jenuh karo iku). Ilustrasi ing ngisor iki minangka gambaran saka kahanan ing banyu jenuh udara. AQUALABO-PF-CAP-C-00141-Optod-Numerical-Sensor-fig-10
  • Sensor kudu tetep garing sajrone proses kalibrasi. Tetesan banyu sing nempel ing membran sensor bisa ngrusak asil pangukuran.
  •  Tekanan udara lan suhu kudu tetep konstan sajrone kalibrasi.

 Kalibrasi ing 1 titik.
Kalibrasi ing 1 titik kasusun ing propping munggah 100% titik: please takon bab ndhuwur (kalibrasi slope).

Pangopènan

Jadwal pangopènan nuduhake interval minimal kanggo tugas pangopènan biasa. nindakake
tugas pangopènan luwih kerep kanggo aplikasi sing nimbulaké elektroda fouling.
Cathetan: Aja mbongkar probe kanggo pangopènan utawa reresik.

  • Sensor kudu tetep resik, utamane ing area sekitar membran optik. Anane biofilm ing tutup membran bisa nyebabake kesalahan pangukuran.
  • Membran sing reged kudu diresiki nganggo banyu anget lan sabun. Spons alus kudu digunakake kanggo ngresiki (ora spons gosok abrasive).
  • Yen sensor ora bisa digunakake, kudu dibilas sadurunge disimpen, lan tutup protèktif kudu dipasang karo kasus protèktif lan permukaan sing nyerep lembab (kaya katun).

Reresik.
Cuci kanthi teliti sensor lan membran kanthi banyu sing resik.
Yen celengan kaya biofilm utawa lendhut tetep, usap membran kasebut alon-alon nganggo kain manis utawa kertas penyerap.
manungsa waé: Kanggo versi Titanium ngresiki awak sensor kanthi aseton (aja nggunakake roh metilasi, etanol utawa metanol).

Owah-owahan saka DODISK.
Wektu urip rata-rata DODISK yaiku 2 taun.
Yen DODISK rusak utawa angel ing proses kalibrasi, DODISK bakal diganti.

  • Bukak kantong ireng lan njupuk tablet aktif (DODISK ing wadhah plastik putih) lan segel.
  • Tahan sensor vertikal ing udhara.
    Copot saringan kanggo ngakses DODISK sing digunakake. Copot gasket lan DODISK digunakake. AQUALABO-PF-CAP-C-00141-Optod-Numerical-Sensor-fig-11
  • Tahan sensor vertikal.
    Priksa alur kanggo manca. Posisi 16 x 1 O-ring ing alur.
  • Tahan sensor vertikal.
    Posisi DO-Disk lan nduwèni, sirah-centered, karo lumahing ireng DO-Disk katon.
  • Tahan sensor vertikal.
    Meneng strainer kanggo mandeg, wadhah DO-Disk bakal tengah karo nunyuk. AQUALABO-PF-CAP-C-00141-Optod-Numerical-Sensor-fig-12

Panyimpenan.
Kanthi tujuan supaya pastille aktif kanthi cepet, njaga membran hydrated karo kasus protèktif lan lumahing absorbent lembab (kaya wool katun). Sawise panyimpenan garing, rehydrate membran kanggo periode 12 jam.

Layanan Sawise-Sales AQUALABO
AQUALABO
115 Rue Michel MARION
56850 CAUDAN - Prancis
Tel .: +33 (0) 4 11 71 97 41

Dokumen / Sumber Daya

AQUALABO PF-CAP-C-00141 Optod Numerical Sensor [pdf] Manual pangguna