WEINTEK-logo

WEINTEK KEYENCE KV-8000-KV-X Symbolic Ethernet Programmable Logic Controller

WEINTEK-KEYENCE-KV-8000-KV-X-Symbolic-Ethernet-Programmable-Logic-Controller-product

Spesifikasi

Instruksi Instalasi

Setelan HMI: 

Paramèter Dianjurake Pilihan Cathetan
Tipe PLC KEYENCE KV-8000/KV-X (Simbolis) (Ethernet)
PLC I/F Ethernet
Pelabuhan no. 8500
Jinis piranti KV8000 KV8000 / KVX
Simulator online ya wis Multi-HMI nyambungake ya wis

Ekspor Tags:

Software KV STUDIO nggawe tag:

  1. Variabel -> Cerected tag ing tabel Global utawa Lokal.WEINTEK-KEYENCE-KV-8000-KV-X-Symbolic-Ethernet-Programmable-Logic-Controller-fig1
  2. Dhukungan alamat Sturcutre. WEINTEK-KEYENCE-KV-8000-KV-X-Symbolic-Ethernet-Programmable-Logic-Controller-fig2
  3. Ekspor tag: File -> Output CSV/TXT file -> Informasi variabel WEINTEK-KEYENCE-KV-8000-KV-X-Symbolic-Ethernet-Programmable-Logic-Controller-fig3

Ngimpor Tags:

  1. Ing EasyBuilder Pro -> Setelan Parameter Sistem -> Driver Anyar (KV-8000) -> Impor Tags. WEINTEK-KEYENCE-KV-8000-KV-X-Symbolic-Ethernet-Programmable-Logic-Controller-fig4
  2. Pilih .txt file kanggo ngimpor. WEINTEK-KEYENCE-KV-8000-KV-X-Symbolic-Ethernet-Programmable-Logic-Controller-fig5
  3. Ngimpor sawetara utawa kabeh tags WEINTEK-KEYENCE-KV-8000-KV-X-Symbolic-Ethernet-Programmable-Logic-Controller-fig6
  4. Pilih ing tag sampeyan pengin ngimpor ing Tag Manajer, tekan OK. WEINTEK-KEYENCE-KV-8000-KV-X-Symbolic-Ethernet-Programmable-Logic-Controller-fig7
  5. Diimpor tag informasi kasil. WEINTEK-KEYENCE-KV-8000-KV-X-Symbolic-Ethernet-Programmable-Logic-Controller-fig8

Dhukungan Tipe Piranti

Jinis data Format data EasyBuilder Memo
BOOL dicokot
INT BCD 16-bit, Hex, Binary, Signed 16-dicokot
UINT BCD 16-bit, Hex, Binary, Unsigned 16-dicokot
DINT BCD 32-bit, Hex, Binary, Signed 32-dicokot
UDINT BCD 32-bit, Hex, Binary, Unsigned 32-dicokot
NYATA Ngambang 32-bit 32-dicokot
LREAL Ngambang 64-bit 64-dicokot * Cathetan 1
STRING Larik tembung kanggo input lan tampilan ASCII * Cathetan 2
 

Array

BOOL, INT, UINT, DINT, UDINT, REAL,

LREAL, Struktur

* Cathetan 3

 

Struktur

BOOL, INT, UINT, DINT, UDINT, NYATA, LREAL, STRING

Array

  • Cathetan 1: EBPro V6.03.02 utawa mengko ndhukung 64 bit jinis data (CMT Series mung), nanging Wigati dimangerteni menawa sawetara watesan alamat 48 bit ing maksimum.
  • Cathetan 2: String Ing EasyBuilder Pro, mung alamat sing bisa dipilih, lan ndhukung dawa string nganti 2000.WEINTEK-KEYENCE-KV-8000-KV-X-Symbolic-Ethernet-Programmable-Logic-Controller-fig9
  • Cathetan 3: Dhukungan 1~3D array, 4D arrays lan ndhuwur ora bisa diimpor.

Wiring Diagram

Kabel Ethernet:

WEINTEK-KEYENCE-KV-8000-KV-X-Symbolic-Ethernet-Programmable-Logic-Controller-fig10

Pitakonan

Kepiye carane nyambungake pirang-pirang HMI?

Sampeyan bisa nyambungake pirang-pirang HMI nggunakake opsi simulator on-line ing setelan HMI.

Apa dawa senar maksimum sing didhukung kanggo jinis data STRING?

Ing EasyBuilder Pro, mung alamat sing bisa dipilih, lan ndhukung dawa string nganti 2000.

Dokumen / Sumber Daya

WEINTEK KEYENCE KV-8000-KV-X Symbolic Ethernet Programmable Logic Controller [pdf] Pandhuan pangguna
KEYENCE KV-8000-KV-X, KEYENCE KV-8000-KV-X Symbolic Ethernet Programmable Logic Controller, Symbolic Ethernet Programmable Logic Controller, Ethernet Programmable Logic Controller, Programmable Logic Controller, Logic Controller

Referensi

Ninggalake komentar

Alamat email sampeyan ora bakal diterbitake. Kolom sing dibutuhake ditandhani *