RICELAKE - logoCounterpart Configurable Count Indikator
Instruksi Manual

Counterpart Configurable Count Indikator

WeighVault ngidini pangguna nambah, ngowahi lan ngakses ID liwat Ethernet. WeighVault ngluwihi watesan ID ing Papan Counterpart lan ngilangi parameter ID ing panel ngarep. Iki nglumpukake data nalika ana transaksi, lan menehi laporan rinci sing bisa diekspor menyang macem-macem file format kalebu Microsoft® Excel®, Microsoft® Word®, lan PDF.

RICELAKE Counterpart Configurable Count Indicator - Gambar 1

Syarat Katrangan
WeighVault Requirements • Windows® 10 build 1607 utawa luwih anyar (mung 64 bit) utawa OS Windows Server sing padha
• 2.0 prosesor GHz utawa luwih cepet
• 250 MB papan drive needed kanggo nginstal
• 8 GB ram utawa luwih
• Microsoft® SQL Server®
2019 (Edition Express kalebu)
• A didhukung web browser (Google® Chrome®, Microsoft® Edge®, Mozilla® Firefox® )
• Sambungan TCP/IP menyang indikator
Requirements jaringan • PC sing nganggo layanan WeighVault kudu duwe alamat IP statis
• Dikenal alamat IP lan subnet saka host PC / server jaringan
Requirements liyane • Indikator kudu disambungake menyang PC liwat Ethernet
• Setelan WeighVault tartamtu kudu dikonfigurasi ing menu indikator
Sambungan Ethernet • Antarmuka TCP/IP Ethernet Onboard

Tabel 1. Requirements Sistem

Instalasi

1.1 Instal Piranti Lunak Komputer WeighVault
Kanggo instruksi instalasi lan konfigurasi WeighVault, deleng WeighVault kanggo Manual Teknis Counterpart (PN 212862).
1.2 Sambungan Ethernet Onboard Counterpart
Tindakake ing ngisor iki kanggo nyambung menyang port RJ45 (J6) ing Papan CPU:
WARNING: Sadurunge mbukak unit, priksa manawa kabel daya wis pedhot saka stopkontak.
Gunakake tali bangkekan kanggo grounding kanggo nglindhungi komponen saka discharge elektrostatik (ESD) nalika digunakake nang enclosure.

  1. Copot Counterpart saka sumber daya.
  2. Copot papat tutup soyo tambah bolts saka indikator.
    RICELAKE Counterpart Configurable Count Indicator - Gambar 2
  3. Copot tutup saka indikator lan pasang mudhun ing alas anti-statis.
  4. Kasebut kanthi teliti, mbusak cutout saka tutup.
  5. Lebokake grommet (kalebu karo Counterpart) menyang potongan.
    RICELAKE Counterpart Configurable Count Indicator - Gambar 3
  6. Pasang kabel Ethernet menyang tutup.
  7. Sambungake kabel Ethernet menyang papan CPU port RJ45 (J6).
  8. Sambungake ujung kabel Ethernet gratis menyang piranti jaringan sing sesambungan karo komputer sing nganggo piranti lunak WeighVault (kayata router utawa switch) utawa komputer sing nganggo piranti lunak WeighVault.
  9. Pasang maneh tutup kanthi papat bolt dicopot ing langkah 2.
  10. Instalasi hardware wis rampung.

Konfigurasi Nomer Port Host lan Alamat IP

Indikator komunikasi karo PC inang liwat TCP Port 5466. Supaya komunikasi kedaden, indikator mbutuhake alamat IP saka PC inang. Mulane, host mbutuhake alamat IP statis (ora dinamis).
Yen nggunakake server jaringan, njaluk administrator jaringan nyedhiyakake alamat IP server, lan konfirmasi alamat kasebut statis. Yen nggunakake PC, deleng pandhuan sing diwenehake karo Windows kanggo mbantu ngatur komputer nganggo alamat IP statis.
PENTING: Yen PC host utawa Server ngemot firewall aa, bisa uga kudu nggawe pangecualian kanggo TCP Port 5466.

Konfigurasi Komunikasi Jaringan Ethernet Onboard Counterpart

Port Ethernet terpadu kudu dikonfigurasi. Gambar 4 nampilake path menu kanggo menu ETHERNET.

RICELAKE Counterpart Configurable Count Indicator - Gambar 4

CATETAN: Waca Counterpart Technical Manual (PN 118677) kanggo informasi luwih lengkap babagan konfigurasi parameter.
Kanggo ngatur paramèter Counterpart, tindakake ing ngisor iki:

  1. Kanthi jumper Audit ing posisi OFF, penet. RICELAKE Counterpart Configurable Count Indicator - lambang 1Menu mbukak.
  2. Navigasi menyang SETUP → CONFIG → SCALES → ETHERNET.
  3. Pencet RICELAKE Counterpart Configurable Count Indicator - lambang 2(↓). tampilan DHCP. B/N JARING KOTOR
  4.  PencetRICELAKE Counterpart Configurable Count Indicator - lambang 2 (↓). Tampilan konfigurasi saiki. B/N JARING KOTOR
  5. Pencet RICELAKE Counterpart Configurable Count Indicator - lambang 3(→) nganti OFF disetel. nyetak
  6. PencetRICELAKE Counterpart Configurable Count Indicator - lambang 4 kanggo nampa konfigurasi lan maju menyang parameter sabanjure. TARE
  7. Baleni konfigurasi kanggo paramèter sing kadhaptar ing Tabel 2 ing kaca 4.
Paramèter Katrangan Konfigurasi
ALAMAT IP Nemtokake alamat IP menyang Counterpart Setel menyang alamat IP statis sing kasedhiya (konsultasi karo administrator jaringan)
MASKER NET Nyetel subnet mask, yen perlu 255.255.255.0 (konsultasi karo administrator jaringan)
DFLTGTWY Nyetel gateway gawan, yen perlu Konsultasi karo administrator jaringan
DNSPRI DNS utami, yen perlu Konsultasi karo administrator jaringan
DNSSEC DNS sekunder, yen perlu Konsultasi karo administrator jaringan
LC LMSTNM jeneng LCL Konsultasi karo administrator jaringan
PORT Nomer Pod Pelabuhan 10001
REMOTE IP Alamat IP jarak jauh Alamat IP server / komputer sing mlaku WeighVault
REMOTE PT port remot 5466
MAC alamat MAC Pengenal unik sing diwenehake menyang Ethernet (ora bisa diganti)
Woh-wohan Aktifake WeighVault Setel menyang ONBOARD kanggo nggunakake sambungan Ethernet.

Tabel 2. Parameter lan Pilihan Menu ETHERNET

Nggunakake WeighVault

Sistem Counterpart WeighVault saiki wis siyap digunakake.

  1. Miwiti WeighVault lan ngakses bagean Data kanggo nambah ID menyang database. Kanggo instruksi operasi WeighVault, WeighVault kanggo Manual Teknis Counterpart (PN 212862).
  2. Ing Counterpart, nyoba ngelingi ID kasebut kanthi mencet tombol ID, ngetik nomer ID banjur pencet Ketik.
  3. Counterpart nggulung pesen sing nyatakake yen lagi mbukak ID.
  4. Gumantung ing status sambungan, Counterpart bakal:
    • Tampilake pesen Loading ID saka PC yen sambungan kasil.
    • Nuduhake pesen Ora ana ID utawa mbukak ID saka memori lokal (yen diprogram). Yen ora kasil, verifikasi kabeh setelan ing Counterpart, kertu pilihan, lan PC host. Uga verifikasi yen firewall mblokir akses menyang port 5466 saka host, lan kabeh wiring bener.

RICELAKE - logo© Rice Lake Weighing Systems Isi bisa diganti tanpa kabar.
230 W. Coleman St.
Rice Lake, WI 54868
USA
AS 800-472-6703
Kanada/Meksiko 800-321-6703
Internasional 715-234-9171
Eropa +31 (0)26 472 1319

Dokumen / Sumber Daya

RICELAKE Counterpart Configurable Count Indikator [pdf] Instruksi Manual
Counterpart Configurable Counting Indicator, Configurable Counting Indicator, Counting Indicator, Indikator

Referensi