OPERATOR PAGE PARAMETER
Paramèter Setelan (Nilai Default)
Wektu Mulai Command >>Wektu Abort Command >> Ya Ora (Default: Ora)
Interval Wektu (H:M) >> 0.00 nganti 500.00 (HH:MM)(Default: 0.10)
Ctrl Set Value >> Setpoint LO limit menyang Setpoint HI limit (Default: 25.0)
Penyimpangan LO >> 0.2 nganti 99.9 (Default: 2.0)
HI Penyimpangan >> 0.2 nganti 99.9 (Default: 2.0)
Ganti Sandi >> 1 nganti 100 (Default: 0)
SUPERVISORY > PARAMETER SERIAL
Paramèter Setelan (Nilai Default)
ID Piranti >> 1 nganti 127 (Default: 1)
Baud Rate >> 2400, 4800,9600, 19200,38400, 57600 (Default : 9600)
Paritas >> Ora Ana, Genap, Ganjil (Default: Genap)
Izin Tulis Serial >> Ora Ya (Default: Ora)
SUPERVISORY > SENSOR INPUT
Paramèter Setelan (Nilai Default)
Nul Offset >> -50.0 nganti 50.0 (Default: 0.0)
PENGAWASAN > KONTROL
Paramèter Setelan (Nilai Default)
Tune >> Ya Ora (Default: Ora)
Setpoint LO Limit >> Kanggo Input Thermocouple:-200 nganti Setpoint HI Limit Kanggo RTD Input:-99.9 nganti Setpoint HI Limit (Default: 0.0)
Setpoint Batas HI >> Kanggo Input Thermocouple: Setpoint LO Limit nganti 9999 Kanggo RTD Input: Setpoint LO Limit nganti 600.0(Default: 600.0)
Setpoint Kompresor >> 0.0 nganti 100.0 (Default: 45.0)
Kompresor Hyst >> 0.1 nganti 99.9 (Default: 2.0)
Heat Ctrl Action >> PID ON-OFF (Default: PID)
Heat Hyst >> 0.1 nganti 99.9 (Default: 0.2)
Kalor Mung Kontrol Zona Kontrol Panas + Kelangan : Tunggal Zona Kontrol Panas + Kelangan : Dual
Band Proporsional >>0.1 nganti 999.9 (Default: 50.0) Band Proporsional >>0.1 nganti 999.9 (Default: 50.0) Cz Prop Band >> Band proporsional kanggo zona Pre-dominan Cool 0.1 nganti 999.9 (Default: 50.0)
Wektu Integral >> 0 nganti 3600 detik (Default: 100 detik) Wektu Integral >> 0 nganti 3600 detik (Default: 100 detik) Cz Wektu Integral >>Wektu Integral kanggo Cool Pre-dominan zone0 nganti 3600 detik (Default: 100 detik)
 Wektu Turunan >>0 nganti 600 detik (Default: 16 detik)  Wektu Turunan >>0 nganti 600 detik (Default: 16 detik) Cz Wektu Turunan >> Wektu Turunan kanggo Zona Pre-dominan Kelangan 0 nganti 600 detik (Default: 16 detik)
Kalor Mung Kontrol Zona Kontrol Panas + Kelangan : Tunggal Zona Kontrol Panas + Kelangan : Dual
Wektu Siklus >>0.5 nganti 100.0 detik (Default: 10.0 detik) Wektu Siklus >>0.5 nganti 100.0 detik (Default: 10.0 detik) Pita Prop Hz >> Band Proporsional kanggo zona Pre-dominan Panas 0.1 nganti 999.9 (Default: 50.0)
Overshoot Nyandhet >>Aktifake Pateni (Default: Pateni) Overshoot Nyandhet >>Aktifake Pateni (Default: Pateni) Wektu Integral Hz >>Wektu Integral kanggo zona Pre-dominan Panas0 nganti 3600 detik (Default: 100 detik)
Faktor Cutoff >>1.0 nganti 2.0 detik (Default: 1.2 detik) Faktor Cutoff >>1.0 nganti 2.0 detik (Default: 1.2 detik) Wektu Turunan Hz >> Wektu Turunan kanggo zona Pre-dominan Panas 0 nganti 600 detik (Default: 16 detik)
Wektu Siklus >>0.5 nganti 100.0 detik (Default: 10.0 detik)
Overshoot Nyandhet >> Aktifake Pateni (Default: Pateni)
Faktor Cutoff >>1.0 nganti 2.0 detik (Default: 1.2 detik)
SUPERVISORY > PASSWORD
Paramèter Setelan (Nilai Default)
Ganti Sandi >> 1000 nganti 1999 (Default: 123)
PENGAWASAN > MUTU
Paramèter
Metu Mode Setup >>
PABRIK > SENSOR INPUT
Paramèter Setelan (Nilai Default)
Tipe Input >> Rujuk Tabel 1 (Default: RTD Pt100)
Filter Konstan >> 0.5 nganti 60.0 (Default: 0.5)
PABRIK > PARAMETER ALARM
Paramèter Setelan (Nilai Default)
Histeresis >> 0.1 nganti 99.9 (Default: 0.2)
Ngalangi >> Ya Ora (Default: Ya)
PABRIK > PILIH HEAT COOL
Paramèter Setelan (Nilai Default)
Strategi Kontrol >> Kalor Mung Kelangan Mung Kalor + Kelangan (Default: Kalor + Kelangan)
Strategi Kontrol: Mung Kelangan
Wektu Tundha (detik) >> 0 nganti 1000 Detik (Default: 200 Detik)
Strategi Kontrol: Panas + Kelangan
Strategi Kompresor >> CONT. OFF CONT. ON SP BASED PV BASED(Default: SP BASED)
CONT. ON SP BASED PV BASED
WektuTundha (detik) >>0 nganti 1000 Detik (Default: 200 Detik) Nilai Set Wates >>0.0 nganti 100.0 (Default: 45.0) Kompresor SP >>0.0 nganti 100.0 (Default: 45.0)
Zona Kontrol >>Single Dual (Default: Single) WektuTundha (detik) >>0 nganti 1000 Detik (Default: 200 Detik)
WektuTundha (detik) >>0 nganti 1000 Detik (Default: 200 Detik)
PABRIK > PARAMETER TIMER
Paramèter Setelan (Nilai Default)
Aktifake >> Ora Ya (Default: Ora)
Mulai Band >> 0 nganti 999.9 (Default: 0.5)
Strategi Holdback >> Ora Ana Mundhut Loro (Default: Ora Ana)
Tahan Band >> 0.1 nganti 999.9 (Default: 0.5)
Panas Mati >> Ora Ya (Default: Ora)
Cool Off >> Ora Ya (Default: Ora)
Daya Recovery >> Batal Wiwiti maneh Terus (Default: Wiwiti maneh)
PABRIK > lawang mbukak
Paramèter Setelan (Nilai Default)
Aktifake >> Ya Ora (Default: Ora)
Ngalih Logika >> Tutup : Lawang Mbukak : Lawang Mbukak (Default : Tutup : Lawang Mbukak)
Lawang Alrm Dly (detik) >> 0 nganti 1000 Detik (Default: 60 Detik)
PABRIK > PASSWORD
Paramèter Setelan (Nilai Default)
Ganti Sandi >> 2000 nganti 2999 (Default: 321)
PABRIK > PABRIK DEFAULT
Paramèter Setelan (Nilai Default)
Setel menyang Default >> Ya Ora (Default: Ora)
PABRIK > MUTU
Paramèter
Metu Mode Setup >>
TABEL 1
Pilihan Range (Min. nganti Maks.) Resolusi & Unit
Tipe J (Fe-K) 0.0 nganti +960.0°C 1 °C
Tipe K (Cr-Al) -200.0 nganti +1376.0 ° C
Tipe T (Cu-Con) -200.0 nganti +387.0 ° C
Tipe R (Rh-13%) 0.0 nganti +1771.0°C
Tipe S (Rh-10%) 0.0 nganti +1768.0°C
Tipe B 0.0 nganti +1826.0°C
Tipe N 0.0 nganti +1314.0°C
Reserved kanggo jinis Thermocouple khusus pelanggan sing ora kadhaptar ing ndhuwur. Jinis kasebut kudu ditemtokake miturut jinis termokopel sing dipesen (opsional ing panyuwunan).
RTD Pt100 -99.9 nganti +600.0 ° C 0.1 °C
PV ERROR INDIKASI
Pesen Jinis Kesalahan sabab
BUKA Sensor mbukak RTD Pt100 / Thermocouple is Broken / Open
OVR Over-range Suhu ndhuwur Max. Range sing ditemtokake
UNR Under-range Suhu ngisor Min. Range sing ditemtokake
KUNCI PANEL NGAREP
Simbol Kunci Fungsi
Simbol-simbol  Gulung Pencet kanggo nggulung macem-macem Layar Informasi Proses ing Mode Operasi Normal.
Simbol-simbol Weker Ngakoni Pencet kanggo ngakoni lan bisu (yen aktif) output weker.
Simbol-simbol  TURUN Pencet kanggo nyuda nilai parameter. Pencet sapisan nyuda nilai kanthi siji count; terus dipencet nyepetake owah-owahan.
Simbol-simbol  UP Pencet kanggo nambah nilai parameter. Pencet sapisan nambah nilai kanthi siji count; terus dipencet nyepetake owah-owahan.
Simbol-simbol  UP-UP  Pencet kanggo mlebu utawa metu saka mode persiyapan.
Simbol-simbol  ENTER Pencet kanggo nyimpen nilai parameter sing disetel lan kanggo nggulung menyang parameter sabanjure.

SAMBUNGAN LISTRIK

SAMBUNGAN LISTRIK

OPERATOR PAGE PARAMETER
Paramèter Setelan (Nilai Default)
Wektu Mulai Command >>Wektu Abort Command >> Ya Ora (Default: Ora)
Interval Wektu (H:M) >> 0.00 nganti 500.00 (HH:MM)(Default: 0.10)
Ctrl Set Value >> Setpoint LO limit menyang Setpoint HI limit (Default: 25.0)
Penyimpangan LO >> 0.2 nganti 99.9 (Default: 2.0)
HI Penyimpangan >> 0.2 nganti 99.9 (Default: 2.0)
Ganti Sandi >> 1 nganti 100 (Default: 0)
SUPERVISORY > SENSOR INPUT
Paramèter Setelan (Nilai Default)
Nul Offset >> -50.0 nganti 50.0 (Default: 0.0)
SUPERVISORY > PARAMETER SERIAL
Paramèter Setelan (Nilai Default)
ID Piranti >> 1 nganti 127 (Default: 1)
Baud Rate >> 2400, 4800,9600, 19200,38400, 57600 (Default : 9600)
Paritas >> Ora Ana, Genap, Ganjil (Default: Genap)
Izin Tulis Serial >> Ora Ya (Default: Ora)
PENGAWASAN > KONTROL
Paramèter Setelan (Nilai Default)
Tune >> Ya Ora (Default: Ora)
Setpoint LO Limit >> Kanggo Input Thermocouple:-200 nganti Setpoint HI Limit Kanggo RTD Input:-99.9 nganti Setpoint HI Limit (Default: 0.0)
Setpoint Batas HI >> Kanggo Input Thermocouple: Setpoint LO Limit nganti 9999 Kanggo RTD Input: Setpoint LO Limit nganti 600.0(Default: 600.0)
Setpoint Kompresor >> 0.0 nganti 100.0 (Default: 45.0)
Kompresor Hyst >> 0.1 nganti 99.9 (Default: 2.0)
Heat Ctrl Action >> PID ON-OFF (Default: PID)
Heat Hyst >> 0.1 nganti 99.9 (Default: 0.2)
Kalor Mung Kontrol Zona Kontrol Panas + Kelangan : Tunggal Zona Kontrol Panas + Kelangan : Dual
Band Proporsional >>0.1 nganti 999.9 (Default: 50.0) Band Proporsional >>0.1 nganti 999.9 (Default: 50.0) Cz Prop Band >> Band proporsional kanggo zona Pre-dominan Cool 0.1 nganti 999.9 (Default: 50.0)
 Wektu Integral >> 0 nganti 3600 detik (Default: 100 detik)  Wektu Integral >> 0 nganti 3600 detik (Default: 100 detik) Cz Wektu Integral >>Wektu Integral kanggo Cool Pre-dominan zone0 nganti 3600 detik (Default: 100 detik)
 Wektu Turunan >>0 nganti 600 detik (Default: 16 detik)  Wektu Turunan >>0 nganti 600 detik (Default: 16 detik) Cz Wektu Turunan >> Wektu Turunan kanggo Zona Pre-dominan Kelangan 0 nganti 600 detik (Default: 16 detik)
Kalor Mung Kontrol Zona Kontrol Panas + Kelangan : Tunggal Zona Kontrol Panas + Kelangan : Dual
 Wektu Siklus >>0.5 nganti 100.0 detik (Default: 10.0 detik)  Wektu Siklus >>0.5 nganti 100.0 detik (Default: 10.0 detik) Pita Prop Hz >> Band Proporsional kanggo zona Pre-dominan Panas 0.1 nganti 999.9 (Default: 50.0)
Overshoot Nyandhet >>Aktifake Pateni (Default: Pateni) Overshoot Nyandhet >>Aktifake Pateni (Default: Pateni) Wektu Integral Hz >>Wektu Integral kanggo zona Pre-dominan Panas0 nganti 3600 detik (Default: 100 detik)
Faktor Cutoff >>1.0 nganti 2.0 detik (Default: 1.2 detik) Faktor Cutoff >>1.0 nganti 2.0 detik (Default: 1.2 detik) Wektu Turunan Hz >> Wektu Turunan kanggo zona Pre-dominan Panas 0 nganti 600 detik (Default: 16 detik)
Wektu Siklus >>0.5 nganti 100.0 detik (Default: 10.0 detik)
Overshoot Nyandhet >> Aktifake Pateni (Default: Pateni)
Faktor Cutoff >>1.0 nganti 2.0 detik (Default: 1.2 detik)
SUPERVISORY > PASSWORD
Paramèter Setelan (Nilai Default)
Ganti Sandi >> 1000 nganti 1999 (Default: 123)
PENGAWASAN > MUTU
Paramèter Setelan (Nilai Default)
Metu Mode Setup >> Ya Ora (Default: Ora)
PABRIK > SENSOR INPUT
Paramèter Setelan (Nilai Default)
Tipe Input >> Rujuk Tabel 1 (Default: RTD Pt100)
Filter Konstan >> 0.5 nganti 60.0 (Default: 0.5)
PABRIK > PARAMETER ALARM
Paramèter Setelan (Nilai Default)
Histeresis >> 0.1 nganti 99.9 (Default: 0.2)
Ngalangi >> Ya Ora (Default: Ya)
PABRIK > PILIH HEAT COOL
Paramèter Setelan (Nilai Default)
Strategi Kontrol >> Kalor Mung Kelangan Mung Kalor + Kelangan (Default: Kalor + Kelangan)
Strategi Kontrol: Mung Kelangan
Wektu Tundha (detik) >> 0 nganti 1000 Detik (Default: 200 Detik)
Strategi Kontrol: Panas + Kelangan
Strategi Kompresor >> CONT. OFF CONT. ON SP BASED PV BASED(Default: CONT. ON)
CONT. ON SP BASED PV BASED
WektuTundha (detik) >>0 nganti 1000 Detik (Default: 200 Detik) Nilai Set Wates >>0.0 nganti 100.0 (Default: 45.0) Kompresor SP >>0.0 nganti 100.0 (Default: 45.0)
Zona Kontrol >>Single Dual (Default: Single) WektuTundha (detik) >>0 nganti 1000 Detik (Default: 200 Detik)
WektuTundha (detik) >>0 nganti 1000 Detik (Default: 200 Detik)
PABRIK > PARAMETER TIMER
Paramèter Setelan (Nilai Default)
Aktifake >> Ora Ya (Default: Ora)
Mulai Band >> 0 nganti 999.9 (Default: 0.5)
Strategi Holdback >> Ora Ana Mundhut Loro (Default: Ora Ana)
Tahan Band >> 0.1 nganti 999.9 (Default: 0.5)
Panas Mati >> Ora Ya (Default: Ora)
Cool Off >> Ora Ya (Default: Ora)
Daya Recovery >> Batal Wiwiti maneh Terus (Default: Wiwiti maneh)
PABRIK > lawang mbukak
Paramèter Setelan (Nilai Default)
Aktifake >> Ya Ora (Default: Ora)
Ngalih Logika >> Tutup : Lawang Mbukak : Lawang Mbukak (Default : Tutup : Lawang Mbukak)
Lawang Alrm Dly (detik) >> 0 nganti 1000 Detik (Default: 60 Detik)
PABRIK > PASSWORD
Paramèter Setelan (Nilai Default)
Ganti Sandi >> 2000 nganti 2999 (Default: 321)
PABRIK > PABRIK DEFAULT
Paramèter Setelan (Nilai Default)
Setel menyang Default >> Ya Ora (Default: Ora)
PABRIK > MUTU
Paramèter Setelan (Nilai Default)
Metu Mode Setup >> Ya Ora (Default: Ora)
TABEL 1
Pilihan Range (Min. nganti Maks.) Resolusi & Unit
Tipe J (Fe-K) 0.0 nganti +960.0°C 1 °C
Tipe K (Cr-Al) -200.0 nganti +1376.0 ° C
Tipe T (Cu-Con) -200.0 nganti +387.0 ° C
Tipe R (Rh-13%) 0.0 nganti +1771.0°C
Tipe S (Rh-10%) 0.0 nganti +1768.0°C
Tipe B 0.0 nganti +1826.0°C
Tipe N 0.0 nganti +1314.0°C
Reserved kanggo jinis Thermocouple khusus pelanggan sing ora kadhaptar ing ndhuwur. Jinis kasebut kudu ditemtokake miturut jinis termokopel sing dipesen (opsional ing panyuwunan).
RTD Pt100 -99.9 nganti +600.0 ° C 0.1 °C
PV ERROR INDIKASI
Pesen Jinis Kesalahan sabab
BUKA Sensor mbukak RTD Pt100 / Thermocouple is Broken / Open
OVR Over-range Suhu ndhuwur Max. Range sing ditemtokake
UNR Under-range Suhu ngisor Min. Range sing ditemtokake
KUNCI PANEL NGAREP
Simbol Kunci Fungsi
Simbol-simbol  Gulung Pencet kanggo nggulung macem-macem Layar Informasi Proses ing Mode Operasi Normal.
Simbol-simbol Weker Ngakoni Pencet kanggo ngakoni lan bisu (yen aktif) output weker.
Simbol-simbol  TURUN Pencet kanggo nyuda nilai parameter. Pencet sapisan nyuda nilai kanthi siji count; terus dipencet nyepetake owah-owahan.
Simbol-simbol  UP Pencet kanggo nambah nilai parameter. Pencet sapisan nambah nilai kanthi siji count; terus dipencet nyepetake owah-owahan.
Simbol-simbol  UP-UP  Pencet kanggo mlebu utawa metu saka mode persiyapan.
Simbol-simbol  ENTER Pencet kanggo nyimpen nilai parameter sing disetel lan kanggo nggulung menyang parameter sabanjure.

SAMBUNGAN LISTRIK

SAMBUNGAN LISTRIK

Dhukungan

101, Diamond Industrial Estate, Navghar,
Jalan Vasai (E), Kab. Palghar – 401 210.
Dodolan : 8208199048 / 8208141446
Dhukungan : 07498799226 / 08767395333
E: sales@ppiindia.net, support@ppiindia.net

Logo Ppi Kab

Dokumen / Sumber Daya

PPI Zenex Plus Pengontrol Suhu Multi-Tujuan [pdf] Manual pangguna
Zenex Plus Pengontrol Suhu Serbaguna, Zenex Plus, Pengontrol Suhu Serbaguna, Pengontrol Suhu, Pengontrol

Referensi

Ninggalake komentar

Alamat email sampeyan ora bakal diterbitake. Kolom sing dibutuhake ditandhani *