LabCon (MAP + Printer)
Rekaman + 4 Pemetaan Saluran + Antarmuka Printer
Manual pangguna
PARAMETER PAGE OPERATOR
| Paramèter | Setelan (Nilai Default) |
| Wektu Mulai Command >> Wektu Abort Command >> |
Ya Ora (Default: Ora) |
| Interval Wektu (H:M) >> | 0.00 nganti 500.00 (HH:MM) (Default: 0.10) |
| Ctrl Set Value >> | Setpoint LO watesan kanggo Setpoint HI watesan (Resolusi 0.1°C kanggo RTD / DC Linear & 1°C kanggo Thermocouple) (Default: 25.0) |
| Ctrl Lo Penyimpangan >> | Kanggo RTD & DC Linear: 0.2 kanggo 99.9 Kanggo Thermocouple: 2 kanggo 99 (Default: 2.0) |
| Ctrl Hi Deviation >> | Kanggo RTD & DC Linear: 0.2 kanggo 99.9 Kanggo Thermocouple: 2 kanggo 99 (Default: 2.0) |
| Ganti Sandi >> | 1 nganti 100 (Default: 0) |
SUPERVISORY > SENSOR INPUT
| Paramèter | Setelan (Nilai Default) |
| Ctrl Zero Offset >> | -50 nganti 50 (Resolusi 0.1°C kanggo RTD / DC Linear & 1°C kanggo Thermocouple) (Default: 0.0) |
| Map-1 Zero Offset >> Map-2 Zero Offset >> Map-3 Zero Offset >> Map-4 Zero Offset >> |
-50 nganti 50 (Resolusi 0.1°C kanggo RTD / DC Linear & 1°C kanggo Thermocouple) (Default: 0.0) |
PENGAWASAN > RAKAMAN
| Paramèter | Setelan (Nilai Default) |
| Rek. Interval (min) >> |
0 nganti 250 Min (Default: 5 Min) |
| Weker Ngalih Rekam >> |
Aktifake Pateni (Default: Aktifake) |
| Del Print Records >> | Ya Ora (Defaul: Ora) |
| Del Tampilan Rekam >> |
Ya Ora (Default: Ora) |
| Wektu RTC >> | 0 kanggo 23 kanggo Jam 0 kanggo 59 kanggo Min (Default: NA) |
| Tanggal RTC >> | 1 nganti 31 (Default: NA) |
| Wulan RTC >> | 1 nganti 12 (Default: NA) |
| Taun RTC >> | 2000 nganti 2099 (Default: NA) |
PENGAWASAN > KONTROL
| Paramèter | Setelan (Nilai Default) |
| Tune >> | Ya Ora (Default: Ora) |
| Setpoint LO Limit >> | Rentang Min kanggo Jinis Input sing Dipilih menyang Setpoint Batas HI (Resolusi 0.1°C kanggo RTD / DC Linear & 1°C kanggo Thermocouple) (Default: 0.0) |
| Setpoint Batas HI >> | Setpoint LO Limit kanggo Max Range kanggo Kapilih Tipe Input (Resolusi 0.1°C kanggo RTD / DC Linear & 1°C kanggo Thermocouple) (Default: 600.0) |
| Setpoint Kompresor >> | 0 nganti 100 (Resolusi 0.1°C kanggo RTD / DC Linear & 1°C kanggo Thermocouple) (Default: 45.0) |
| Kompresor Hyst >> | 0.1 nganti 99.9 (Default: 2.0) |
| Heat Ctrl Action >> | PID ON-OFF (Default: PID) |
| Heat Hyst >> | 0.1 nganti 99.9 (Default: 0.2) |
| Kalor Mung Kontrol | Zona Kontrol Panas + Kelangan: Tunggal | Zona Kontrol Panas + Kelangan: Dual |
| Band Proporsional >> 0.1 nganti 999.9 (Default: 50.0) |
Band Proporsional >> 0.1 nganti 999.9 (Default: 50.0) |
Cz Prop Band >> Proportional Band kanggo Cool Pre-dominant zone 0.1 nganti 999.9 (Default: 50.0) |
| Wektu Integral >> 0 nganti 3600 detik (Default: 100 detik) | Wektu Integral >> 0 nganti 3600 detik (Default: 100 detik) | Cz Wektu Integral >> Wektu Integral kanggo Cool Pre-dominan zone 0 kanggo 3600 sec (Default: 100 detik) |
| Wektu Turunan >> 0 nganti 600 detik (Default: 16 detik) |
Wektu Turunan >> 0 nganti 600 detik (Default: 16 detik) |
Cz Derivative Time >> Derivative Time for Cool Pre-dominant zone 0 nganti 600 detik (Default: 16 detik) |
| Wektu Siklus >> 0.5 nganti 100.0 detik (Default: 10.0 detik) |
Wektu Siklus >> 0.5 nganti 100.0 detik (Default: 10.0 detik) |
Pita Prop Hz >> Pita Proporsional kanggo Zona Pra-dominan Panas 0.1 nganti 999.9 (Default: 50.0) |
| Overshoot Inhibit >> Aktifake Pateni (Default: Pateni) |
Overshoot Inhibit >> Aktifake Pateni (Default: Pateni) |
Wektu Integral Hz >> Wektu Integral kanggo zona Pre-dominan Panas 0 nganti 3600 detik (Default: 100 detik) |
| Faktor Cutoff >> 1.0 nganti 2.0 detik (Default: 1.2 detik) |
Faktor Cutoff >> 1.0 nganti 2.0 detik (Default: 1.2 detik) |
Wektu Turunan Hz >> Wektu Turunan kanggo Zona Predominan Panas 0 nganti 600 detik (Default: 16 detik) |
| Wektu Siklus >> 0.5 kanggo 100.0 sec (Default: 10.0 detik) |
||
| Overshoot Inhibit >> Aktifake Pateni (Default: Pateni) |
||
| Faktor Cutoff >> 1.0 nganti 2.0 detik (Default: 1.2 detik) |
SUPERVISORY > SETTING PRINTER
| Paramèter | Setelan (Nilai Default) |
| Baris Saben Kaca >> | 25 nganti 100 (Default: 65) |
| Margin ndhuwur >> | 1 nganti 5 (Default: 2) |
| Margin ngisor >> | 1 nganti 5 (Default: 2) |
| Header & Footer >> | Ora Ing Kaca Kapisan Saben Kaca (Default: Ora) |
| Aktifake >> | Ya Ora (Default: Ora) |
SUPERVISORY > CETAK ACARA
| Paramèter | Setelan (Nilai Default) |
| Ngalih weker >> RTC Ngowahi >> Interval Modifikasi >> Daya Up >> Lawang Buka >> Listrik Gagal >> Setpoint Ngowahi >> |
ya wis Ora (Default: Ya) |
SUPERVISORY > PASSWORD
| Paramèter | Setelan (Nilai Default) |
| Ganti Sandi >> |
1000 nganti 1999 (Default: 123) |
PENGAWASAN > MUTU
| Paramèter | Setelan (Nilai Default) |
| Metu Mode Setup >> | ya wis Ora (Default: )Ora |
PABRIK > KONTROL SENSOR INPUT
| Paramèter | Setelan (Nilai Default) | ||||||||||||||||||
| Tipe Input >> | Rujuk Tabel 1 (Default: RTD Pt100) | ||||||||||||||||||
| Sinyal LO >> |
|
||||||||||||||||||
| Sinyal HI >> |
|
||||||||||||||||||
| Range LO >> | -199.9 kanggo RANGE HI (Default: 0.0) |
||||||||||||||||||
| Range HI >> | RANGE LO nganti 999.9 (Default: 100.0) |
PABRIK > PARAMETER ALARM
| Paramèter | Setelan (Nilai Default) |
| Histeresis >> | 0.1 nganti 99.9 (Default: 0.2) |
| Ngalangi >> | Ya Ora (Default: Ya) |
PABRIK > PILIH HEAT COOL
| Paramèter | Setelan (Nilai Default) |
| Strategi Kontrol >> | Panas Mung Kelangan Mung Panas + Kelangan (Default: Panas + Kelangan) |
| Strategi Kontrol: Mung Kelangan | |
| Wektu Tundha (detik) >> | 0 nganti 1000 Detik (Default: 200 Detik) |
| Strategi Kontrol: Panas + Kelangan | |
| Strategi Kompresor >> | CONT. OFF CONT. ON SP BASED PV BASED (Default: CONT. ON) |
| CONT. ON | SP BASED | PV BASED |
| Wektu Tundha (detik) >> 0 kanggo 1000 Sec (Default: 200 Detik) |
Nilai Set Wates >> 0 nganti 100 (Resolusi 0.1°C kanggo RTD / DC Linear & 1°C kanggo Thermocouple) (Default: 45.0) |
Wektu Tundha (detik) >> 0 kanggo 1000 Sec (Default: 200 Detik) |
| Zona Kontrol >> Tunggal Dwi (Default: Tunggal) |
||
| Wektu Tundha (detik) >> 0 kanggo 1000 Sec (Default: 200 Sec) |
PABRIK > PARAMETER TIMER SOAK
| Paramèter | Setelan (Nilai Default) |
| Aktifake >> | Ora Ya (Default: Ora) |
| Mulai Band >> | 0 nganti 999.9 (Default: 0.5) |
| Strategi Holdback >> | Ora Ana Mundhut Loro (Default: Ora ana) |
| Tahan Band >> | 0.1 nganti 999.9 (Default: 0.5) |
| Panas Mati >> | Ora Ya (Default: Ora) |
| Cool Off >> | Ora Ya (Default: Ora) |
| Daya Recovery >> | Batal Wiwiti maneh Terus (Default: Wiwiti maneh) |
PABRIK > lawang mbukak
| Paramèter | Setelan (Nilai Default) |
| Aktifake >> | Ya Ora (Default: Ora) |
| Ngalih Logika >> | Tutup: Lawang Mbukak: Lawang Mbukak (Default: Tutup: Door Open) |
| lawang Alrm Dly (detik) >> |
0 kanggo 1000 Sec (Default: 60 Sec) |
PABRIK > GAGAL UTAMA
| Paramèter | Setelan (Nilai Default) |
| Aktifake >> | Ya Ora (Default: Ora) |
| Ngalih Logika >> | Tutup: Listrik Gagal Bukak: Listrik Gagal (Default: Tutup: Listrik Gagal) |
PABRIK > PASSWORD
| Paramèter | Setelan (Nilai Default) |
| Ganti Sandi >> | 2000 nganti 2999 (Default: 321) |
PABRIK > FACTORY DEFAULT
| Paramèter | Setelan (Nilai Default) |
| Setel menyang Default >> | Ya Ora (Default: Ora) |
PABRIK > MUTU
| Paramèter | Setelan (Nilai Default) |
| Metu Mode Setup >> | Ya Ora (Default: Ora) |
TABEL 1
| Apa tegese | Range (Min. nganti Maks.) | Resolusi |
| Termokopel Tipe J | 0 nganti +960°C | Tetep 1 ° C |
| Termokopel Tipe K | -200 nganti +1376 ° C | |
| Tipe T Termokopel | -200 nganti +385 ° C | |
| Termokopel Tipe R | 0 nganti +1770°C | |
| Termokopel Tipe S | 0 nganti +1765°C | |
| Termokopel Tipe B | 0 nganti +1825°C | |
| Termokopel Tipe N | 0 nganti +1300°C | |
| Cadangan | Reserved kanggo jinis Thermocouple khusus pelanggan sing ora kadhaptar ing ndhuwur. Jinis kasebut kudu ditemtokake miturut jinis termokopel sing dipesen (opsional ing panyuwunan). | |
| 3-kawat, RTD Pt100 | -199.9 nganti 600.0°C | didandani 0.1°C |
| 0 nganti 20mA DC saiki | -199.9 kanggo 999.9 Unit | didandani 0.1 unit |
| 4 nganti 20mA DC saiki | ||
| 0 kanggo 5.0V DC voltage | ||
| 0 kanggo 10.0V DC voltage | ||
| 1 kanggo 5.0V DC voltage |
KUNCI PANEL NGAREP
| Simbol | Kunci | Fungsi |
![]() |
Gulung | Pencet kanggo nggulung macem-macem Layar Informasi Proses ing Mode Operasi Normal. |
![]() |
Weker Ngakoni | Pencet kanggo ngakoni lan bisu (yen aktif) output weker. |
![]() |
TURUN | Pencet kanggo nyuda nilai parameter. Pencet sapisan nyuda nilai kanthi siji count; terus dipencet nyepetake owah-owahan. |
![]() |
UP | Pencet kanggo nambah nilai parameter. Pencet sapisan nambah nilai kanthi siji count; terus dipencet nyepetake owah-owahan. |
![]() |
UP-UP | Pencet kanggo mlebu utawa metu saka mode persiyapan. |
![]() |
ENTER | Pencet kanggo nyimpen nilai parameter sing disetel lan kanggo nggulung menyang parameter sabanjure. |
PV ERROR INDIKASI
| Pesen | Jinis Kesalahan | sabab |
![]() |
Sensor mbukak | Sensor (RTD Pt100) Rusak / Mbukak |
![]() |
Over-range | Suhu ndhuwur Max. Range sing ditemtokake |
![]() |
Under-range | Suhu ngisor Min. Range sing ditemtokake |
SAMBUNGAN LISTRIK

101, Diamond Industrial Estate, Navghar,
Jalan Vasai (E), Kab. Palghar – 401 210.
Sales: 8208199048 / 8208141446
Dhukungan: 07498799226 / 08767395333
E: sales@ppiindia.net
support@ppiindia.net
Januari 2022
Dokumen / Sumber Daya
![]() |
Rekaman PPI LabCon + 4 Pemetaan Saluran + Antarmuka Printer [pdf] Manual pangguna Rekaman LabCon 4 Antarmuka Printer Pemetaan Saluran, LabCon, Rekaman Antarmuka Printer Pemetaan 4 Saluran, Antarmuka Printer Pemetaan 4 Saluran, Antarmuka Printer Pemetaan, Antarmuka Printer, Antarmuka |