HRP-600 Series 600W Output Tunggal karo Fungsi PFC

Spesifikasi

  • Model: HRP-600 series
  • Output:
    • DC Voltage:
      • 3.3V, 5V, 7.5V, 12V, 15V, 24V, 36V, 48V
    • Dirating Saiki: 120A
    • Range Saiki: 0 ~ 120A
    • Daya Rated:
      • Kanggo 3.3V lan 5V: 396W
      • Kanggo vol liyanetagiku: 600w
    • Ripple & Noise (maks.): 120mVp-p kanggo 3.3V lan 150mVp-p kanggo
      liyane voltages
    • Voltage Range Penyesuaian:
      • Kanggo 3.3V: 2.8 ~ 3.8V
      • Kanggo 5V: 4.3 ~ 5.8V
      • Lan kisaran sing padha kanggo vol liyanetages
    • Line Regulation, Load Regulation, Setup, Rise Time, Hold Up
      Wektu, Voltage Range, Range Frekuensi, Faktor Daya, Efisiensi, AC
      Saiki, Inrush Saiki ditemtokake kanggo macem-macem output
      voltages.
  • Input:
    • Voltage Range: 85 ~ 264VAC, 120 ~ 370VDC
    • Range Frekuensi: 47 ~ 63Hz
    • Faktor Daya: PF>0.93/230VAC, PF>0.99/115VAC penuh
      momotan
    • Efisiensi: Range saka 78.5% nganti 89%
    • Arus AC, Arus Inrush, Arus Bocor sing ditemtokake kanggo
      kahanan sing beda.

Pandhuan Panggunaan Produk

1. Instalasi:

Priksa manawa input voltage cocog karo sawetara sing ditemtokake. Nyambung
output ndadékaké menyang piranti cocok aman.

2. Powering On:

Sawise instalasi, nguripake sumber daya lan verifikasi sing
output voltages ana ing kisaran sing ditemtokake.

3. Penerbangantage Penyesuaian:

Yen perlu, gunakake voltage imbuhan sawetara kanggo fine-tune ing
output voltage cocog karo syarat piranti sampeyan.

4. Monitoring:

Ngawasi volume output kanthi rutintages lan arus kanggo mesthekake
operasi stabil piranti sing disambungake.

5. Pangopènan:

Tindakake jadwal pangopènan sing disaranake sing kasedhiya ing pangguna
manual kanggo njaga sumber daya ing kondisi optimal.

Pitakonan sing Sering Ditakoni (FAQ)

Q: Apa ripple maksimum lan gangguan kanggo output beda
voltages?

A: Ripple maksimum lan gangguan ditemtokake minangka 120mVp-p kanggo
3.3V lan 150mVp-p kanggo vol liyanetages.

P: Kepiye carane nyetel output voltage?

A: Gunakake voltage kisaran pangaturan sing ditemtokake kanggo saben output
voltage kanggo nyetel output voltage yen perlu.

P: Apa efisiensi khas sumber daya?

A: Efisiensi kisaran saka 78.5% nganti 89% gumantung saka
output voltage.

P: Apa sing kudu ditindakake yen input voltage ngluwihi sing ditemtokake
jangkoan?

A: Aja nyambungake sumber daya kanggo voltagiku njaba
sawetara sing ditemtokake kanggo nyegah karusakan ing unit kasebut.

“`

Output Tunggal 600W kanthi Fungsi PFC

seri HRP-600

Manual pangguna

SPESIFIKASI

UL62368-1

Bauar t gepruft Sicherheit
egelma ge od os be wac g
www. tuv.com ID 2000000000
BS EN/EN62368-1

TPTC004

IEC62368-1

MODEL

HRP-600-3.3 HRP-600-5 HRP-600-7.5 HRP-600-12 HRP-600-15 HRP-600-24 HRP-600-36 HRP-600-48

OUTPUT

DC VOLTAGE

3.3V

5V

RATED SAIKI

120A

120A

RANGE SAIKI

0 ~ 120A

0 ~ 120A

DAYA RATED

396W

600W

RIPPLE & NOISE (maks.) Cathetan.2 120mVp-p 150mVp-p

VOLTAGE ADJ. RANGE

2.8 ~ 3.8V 4.3 ~ 5.8V

VOLTAGE TOLERANSI Cathetan.3 ±2.0%

± 2.0%

REGULASI LINE

± 0.5%

± 0.5%

REGULASI LOAD

± 1.0%

± 1.0%

SETUP, Munggah WAKTU

1800ms, 50ms/230VAC

7.5V

12V

15V

80A

53A

43A

0 ~ 80A

0 ~ 53A

0 ~ 43A

600W

636W

645W

150mVp-p 150mVp-p 150mVp-p

6.8 ~ 9V ± 2.0%

10.2 ~ 13.8V 13.5 ~ 18V

± 1.0%

± 1.0%

± 0.5%

± 0.3%

± 0.3%

± 1.0%

± 0.5%

± 0.5%

3600ms, 50ms/115VAC ing beban lengkap

24V 27A 0 ~ 27A 648W 150mVp-p 21.6 ~ 28.8V ±1.0% ±0.2% ±0.5%

36V 17.5A 0 ~ 17.5A 630W 200mVp-p 28.8 ~ 39.6V ±1.0% ±0.2% ±0.5%

48V 13A 0 ~ 13A 624W 240mVp-p 40.8 ~ 55.2V ±1.0% ±0.2% ±0.5%

WAKTU TAHAN (Typ.)

16ms / 230VAC 16ms / 115VAC ing beban lengkap

VOLTAGE RANGE Cathetan.5 85 ~ 264VAC 120 ~ 370VDC

RANGKA FREKUENSI

47 ~ 63Hz

FAKTOR DAYA (Jenis.)

PF>0.93/230VAC PF>0.99/115VAC ing beban penuh

INPUT

EFISIENSI (Typ.)

78.5%

82%

86%

88%

88%

88%

89%

89%

ARUS AC (Typ.) ARUS INRUSH (Typ.)

7.6A/115VAC 3.6A/230VAC 35A/115VAC 70A/230VAC

KEBOCORAN SAIKI

<1.2mA / 240VAC

kakehan

105 ~ 135% daya output dirating Jinis Proteksi: Watesan saiki konstan, pulih kanthi otomatis sawise kondisi fault dibusak

pangayoman liwat VOLTAGE

3.96 ~ 4.62V 6 ~ 7V

9.4 ~ 10.9V 14.4 ~ 16.8V 18.8 ~ 21.8V 30 ~ 34.8V

Jinis pangayoman: Mati o/p voltage, aktif maneh supaya pulih

41.4 ~ 48.6V

SUHU

Mati o/p voltage, pulih kanthi otomatis sawise suhu mudhun

FUNGSI DC OK SIGNAL FAN CONTROL (Typ.) WORKING TEMP.

PSU nguripake: 3.3 ~ 5.6V; PSU mateni: 0 ~ 1V Beban 35±15% utawa RTH250 Fan ing -40 ~ +70 (Deleng "Derating Curve")

AMBES KERJA

20 ~ 90% RH ora kondensasi

SUHU PENYIMPANAN LINGKUNGAN, KElembaban -40 ~ +85, 10 ~ 95% RH non-kondensasi

TEMP COEFFICIENT

± 0.03%/ (0 ~ 50)

GETERAN

10 ~ 500Hz, 5G 10min./1siklus, 60menit. saben sumbu X, Y, Z

STANDAR KESELAMATAN

UL62368-1, TUV BS EN/EN62368-1, AS/NZS62368.1, EAC TP TC 004 disetujoni

KESELAMATAN & NAHAN VOLTAGE

EMC

RESISTANCE Isolasi

(Cathetan 4)

EMISI EMC

I/PO/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC I/PO/P, I/P-FG, O/P-FG:100M Ohm / 500VDC / 25/ 70% RH Selaras karo BS EN/EN55032 (CISPR32) Kelas B, BS EN/EN61000-3-2,-3, EAC TP TC 020

57.6 ~ 67.2V

EMC kakebalan MTBF

Selaras karo BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS EN/EN61000-6-2, tingkat industri abot, EAC TP TC 020 1333.6K jam min. Telcordia SR-332 (Bellcore); 140.7K jam min. MIL-HDBK-217F (25)

CATETAN LAIN

DIMENSI

218 * 105 * 63.5mm (L * W * H)

KEMASAN

1.5Kg; 8pcs/13Kg/1.34CUFT

http://www.meanwell.com) https://www.meanwell.com/serviceDisclaimer.aspx

File Jeneng:HRP-600-SPEC 2022-08-08

Output Tunggal 600W kanthi Fungsi PFC

Spesifikasi Mekanik
152.4

20.75

10 8.2

Arah aliran udara
I/P 1 2 3
12maks.

63.5

4-M4 L=6
218 152.4 8-M4 L=4 (Loro-lorone)

seri HRP-600

32.8
O/P 1 2 3 4 5 6

9.2

11

Nomer kasus 977A Unit: mm
12 34

105

LED CN100 Kab
SVR1 (Vo ADJ.)

32.8 18 maks.

12.5 38.3 63.5

Pin Terminal Input AC No. Assignment

Pin No. Tugas

1

AC/L

2

AC/N

3

FG

Diagram Blokir

Aku / P

Saringan EMI

FG

Kurva Derating

DC Output Terminal Pin No Assignment

Pin No. Tugas

1~3

-V

4~6

+V

No. Pin Konektor Tugas(CN100): HRS DF11-4DP-2DS utawa sing padha

No Pin Tugas Terminal Perumahan Kawin

1

DC-OK

2

GND

HRS DF11-4DS HRS DF11-**SC

3

+S

utawa padha karo utawa padha

4

-S

AKTIF INRUSH LIMITASI SAIKI

RECTIFIER &
PFC
OTP
KONTROL PFC

POWER SWITCHING
OLP
KONTROL PWM

RECTIFIER &
FILTER
SIRKUIT DETEKSI OTPOVP

Fokus PWM: 70KHz + S + V -V -S
DC OK

Output Derating VS Input Voltage

LOAD (%) LOAD(%)

125

100

100

90

80 80
70

50

60

50

20

40

-40

0

10

20

30

40

50

60 70 (HORIZONTAL)

85

100

125

135

155

264

SUHU AMBIENT ()

INPUT VOLTAGE (V) 60Hz

File Jeneng:HRP-600-SPEC 2022-08-08

Dokumen / Sumber Daya

MEAN WELL HRP-600 Series 600W Output Tunggal kanthi Fungsi PFC [pdf] Manual Pamilik
HRP-600-3.3, HRP-600-5, HRP-600-7.5, HRP-600-12, HRP-600-15, HRP-600-24, HRP-600-36, HRP-600-48, HRP- 600 Series 600W Output Tunggal dengan Fungsi PFC, HRP-600 Series, HRP-600 Series Single Output dengan Fungsi PFC, 600W Single Output dengan Fungsi PFC, 600W Single Output, Single Output dengan Fungsi PFC, Output Tunggal Fungsi PFC, Fungsi PFC, PFC

Referensi

Ninggalake komentar

Alamat email sampeyan ora bakal diterbitake. Kolom sing dibutuhake ditandhani *