Fitur

ZL-7801D minangka pengontrol suhu lan kelembapan universal. Panel ngarep tingkat IP65 dilindhungi, gampang dioperasi lan dipasang. Cocog kanggo ngontrol inkubator, ruang iklim, griya ijo, gudang, lan liya-liyane.

Spesifikasi

  • Sumber daya: 100 ~ 240Vac, 50/60Hz
  • Input: Siji sensor kelembapan kanthi dawa kabel 2 meter.
  • Siji sensor suhu kanthi dawa kabel 1 meter.
  • Output: Suhu lan Kelembapan (R3 lan R5), output: 10A, 250Vac.
  • Liyane (R1 / R2 / R4 / R6) output: 3A, 250Vac.
  • Parameter kasebut kanggo beban resistensi, tinimbang kapasitif lan / utawa induktif!
  • Range setelan: Kelembapan 0.0 ~ 100.0% RH. Set pabrik yaiku 60.0% RH.
  • Suhu -20.0 ~ 100.0 ℃. Set pabrik yaiku 37.8 ℃.
  • Presisi sensor: Suhu: 2%.

Kelembapan:

Sensor Precision Range
khas watesan
ZL-SHr05A 2% RH 4.5% RH 10 ~ 90% RH
4% RH 7.5% RH <10% RH,> 90% RH
ZL-SHr05B 2% RH 2.5% RH 0 ~ 90% RH
2% RH 3.5% RH > 90% RH
  • Lingkungan kerja: -20 ~ 45 ℃. 10 ~ 90% RH tanpa embun.
  • Ukuran kasing: L78 x W34.5 x D71 (mm)
  • Ukuran pengeboran: L 71 x W29 (mm)
  • Bahan kasus: PC + ABS, geni
  • Tingkat perlindungan: IP65 (Panel ngarep mung)

Tampilan

LILYTECH ZL-7801D-Pengontrol Kelembapan-lan-Suhu-anjir (1)

Ikon Tampilan

LILYTECH ZL-7801D-Pengontrol Kelembapan-lan-Suhu-anjir (2)

loro-lorone LILYTECH ZL-7801D-Pengontrol Kelembapan-lan-Suhu-anjir (3)lanLILYTECH ZL-7801D-Pengontrol Kelembapan-lan-Suhu-anjir (4) kedhip: kaping giliran endhog wis tekan kaping pirang-pirang【Kaping giliran endhog U34

Operasi

Setel setpoints

  • Tansah 〖S〗menekan 3 detik kanggo ngetik status setelan. Titik setel suhu ditampilake.
  • Pencet 〖P〗kanggo ngalih ing antarane status setelan suhu lan status setelan kelembapan.
  • Pencet 〖▲〗utawa〖▼〗kanggo nyetel nilai (tetep nandhang sungkowo nggawe set cepet).
  • Tansah 〖S〗menekan 3 detik kanggo nyimpen setelan, banjur metu.
  • Status setelan bakal metu yen ora ana operasi tombol sajrone 30 detik, lan setelan bakal disimpen.

Setel Parameter

  • Tansah 〖P〗 depresi sajrone 3 detik:
  • Yen tembung sandhi "000", ora perlu tembung sandhi kanggo ngetik status setelan parameter.
  • Yen tembung sandhi dudu "000", tampilan "-0", "0" kedhip. Pencet 〖▲〗kanggo nyetel digit sandhi iki.
  • Pencet 〖▼〗kanggo ngalih menyang angka 2 sandhi, banjur pencet 〖▲〗kanggo nyetel.
  • Pencet 〖▼〗kanggo ngalih menyang angka 3 sandhi, banjur pencet 〖▲〗kanggo nyetel.
  • Pencet 〖▼〗kanggo konfirmasi. Yen sandhi bener, ketik status setelan parameter, yen ora metu.

Ing status setelan parameter:

  • pencet 〖S〗utawa〖P〗kanggo milih kode parameter (ndeleng tabel kode ing ngisor iki).
  • Pencet 〖▲〗utawa〖▼〗kanggo nyetel nilai parameter.
  • Tansah 〖P〗menekan 3 detik kanggo nyimpen setelan, banjur metu.
  • Status setelan bakal metu yen ora ana operasi tombol sajrone 30 detik, lan setelan bakal disimpen.

Tabel kode parameter

Kode Fungsi Range Cathetan Pabrik nyetel
U10 Mode kelangan/panas C/H C: pendinginan, H: pemanasan H
U11 Histeresis suhu 0.1 ~ 20 ℃   0.1
U12 R3 wektu pangayoman tundha 2 ~ 600 detik   3
U13 Kalibrasi suhu -9.9 ~ 9.9 ℃   0.0
U14 Suhu dhuwur. Titik wiwitan pangayoman 0.1 ~ 10.0 ℃ nilai relatif 0.3
U15 Suhu dhuwur. Titik mandeg perlindungan -10.0 ~ 10.0 ℃ nilai relatif 0.2
U16 Titik weker suhu dhuwur 0.0 ~ 99.9 ℃ 0.0: mateni weker, nilai relatif 0.0
U17 Titik weker suhu rendah 0.0 ~ 99.9 ℃ 0.0: mateni weker, nilai relatif 0.0
U20 Mode humidifying / dehumidifying H / P H: humidifying, P: dehumidifying H
U21 Histeresis asor 0.1 ~ 20.0% RH   2.0
U22 R5 wektu pangayoman tundha 2 ~ 600 detik   5
U23 Kalibrasi asor -9.9 ~ 9.9% RH   0.0
U24 Asor dhuwur. Titik wiwitan pangayoman 1.0 ~ 20.0% RH nilai relatif 5.0
U25 Asor dhuwur. Titik mandeg perlindungan -20.0 ~ 20.0% RH nilai relatif 2.0
U26 Titik weker kelembapan dhuwur 0 ~ 99.9% RH 0.0: mateni weker, nilai relatif 0.0
U27 Titik weker kelembapan rendah 0 ~ 99.9% RH 0.0: mateni weker, nilai relatif 0.0
U30 Belok ngiwa R1 unit wektu 0 ~ 2 0: sec., 1: min., 2: jam 1
U31 Belok ngiwa R1 wektu 1 ~ 999   90
U32 Belok tengen R2 unit wektu 0 ~ 2 0: sec., 1: min., 2: jam 1
U33 Belok tengen wektu R2 1 ~ 999   90
U34 kaping giliran endhog 0 ~ 999 0: Puteran endhog ora mandheg 0
U35 Reset counter giliran endhog sawise daya diwenehake 0/1 0: ngreset, 1: ora ngreset 0
U40 Timer R4 ing unit wektu 0 ~ 2 0: sec., 1: min., 2: jam 0
U41 Timer R4 ing wektu 1 ~ 999   30
U42 Timer R4 mati unit wektu 0 ~ 2 0: sec., 1: min., 2: jam 1
U43 Timer R4 mati wektu 1 ~ 999   120
 

U44

 

Output R4 mode kerja

 

0 ~ 3

0: mateni  

3

1: output wektu
2: suhu dhuwur / lembab. pangayoman
3: output timer + suhu dhuwur/humi. pangayoman
 

U45

 

Output R6 mode kerja

 

0 ~ 2

0: mateni  

1

1: suhu/lembab. weker, weker gagal
2: suhu dhuwur / lembab. pangayoman
U60 Weker bip 0/1 0: mateni, 1: ngaktifake 1
U99 Sandi 000 ~ 999 000: mateni sandhi 000

Kontrol

Kontrol suhu

  • Mode kelangan (U10 = C)
  • Yen suhu Kamar ≥ Setpoint suhu +【Histeresis suhu U11】, lan R3 wis mandheg kanggo【R3 wektu proteksi wektu tundha U12】, R3 energized.
  • Yen suhu kamar ≤ setpoint suhu, R3 de-energized.

Mode panas (U10 = H)

  • Yen suhu Kamar ≤ Titik setel suhu -【Histeresis suhu U11】, lan R3 wis mandheg kanggo【R3 wektu proteksi tundha U12】, R3 energized.
  • Yen suhu kamar ≥ setpoint suhu, R3 de-energized.

Proteksi suhu dhuwur

  • Yen suhu Kamar ≥ Suhu setpoint + 【Suhu dhuwur. Titik wiwitan perlindungan U14】,
    • R4 energized (nalika 【Output R4 mode kerja U44】=2 utawa 3),
    • R6 energized (nalika 【Output R6 mode kerja U45】=2).
  • Yen suhu Kamar ≤ Suhu setpoint +【Suhu dhuwur. Titik mandheg perlindungan U15】,
    • R4 deenergized (nalika 【Output R4 mode kerja U44】=2 utawa 3),
    • R6 deenergized (nalika 【Mode kerja Output R6 U45】=2).
  • Cathetan: sawise R4 lan R5 de-energized, padha bisa energized maneh sawise 3 detik.

Weker suhu dhuwur/kurang

  • Yen suhu kamar ≥ setpoint suhu +【Titik weker suhu dhuwur U16】,
    • weker, Utawa nampilake suhu Kamar lan "tHi".
  • Yen suhu kamar ≤ setpoint suhu +【Titik weker suhu rendah U17】,
    • weker, Utawa nampilake suhu Kamar lan "tLo".
  • Yen 【Beep warning U60】= 1, bakal ana swara bip nalika nguwatirake.
  • Yen 【Output R6 mode kerja U45】=1, R6 energized nalika nguwatirake.

Kontrol asor

Mode dehumidify (U20 = P)

  • Yen Kelembapan Kamar ≥ Setpoint Kelembapan +【Histeresis Kelembapan U21】, lan R5 wis mandheg kanggo【R5 wektu pangayoman tundha U22】, R5 energized.
  • Yen Kelembapan Kamar ≤ Setpoint Kelembapan, R5 de-energized.

Mode asor (U20 = H)

  • Yen Kelembapan Kamar ≤ Setpoint Kelembapan -【Histeresis Kelembapan U21】, lan R5 wis mandheg kanggo【R5 wektu tundha pangayoman U22】, R5 energized.
  • Yen Kelembapan Kamar ≥ Setpoint Kelembapan, R5 de-energized.

Perlindhungan kelembapan sing dhuwur

  • Yen Kelembapan Kamar ≥ Setpoint Kelembapan +【Asor dhuwur. Titik wiwitan perlindungan U24】,
    • R4 energized (nalika 【Output R4 mode kerja U44】=2 utawa 3),
    • R6 energized (nalika 【Output R6 mode kerja U45】=2).
  • Yen Kelembapan Kamar ≤ Titik setel Kelembapan ora +【Asor dhuwur. Titik mandheg perlindungan U25】,
    • R4 deenergized (nalika 【Output R4 mode kerja U44】=2 utawa 3),
    • R6 deenergized (nalika 【Mode kerja Output R6 U45】=2).
  • Cathetan: sawise R4 lan R5 de-energized, padha bisa energized maneh sawise 3 detik.

Alarm kelembaban dhuwur/kurang

  • Yen Kelembapan Kamar ≥ Setpoint Kelembapan +【Titik weker kelembapan dhuwur U26】,
    • weker, Utawa nampilake Kelembapan Kamar lan "HHi".
  • Yen Kelembapan Kamar ≤ Setpoint Kelembapan +【Titik weker kelembaban rendah U27】,
    • weker, Utawa nampilake Kelembapan Kamar lan "HLo".
  • Yen 【Beep warning U60】= 1, bakal ana swara bip nalika nguwatirake.
  • Yen 【Output R6 mode kerja U45】=1, R6 energized nalika nguwatirake.

Proteksi tundha

  • Sawise daya diwenehake, R3 lan R5 bisa diuripake sawise 【tundha wektu proteksi U12, U22】.
  • Sawise R3 lan R5 de-energized, padha bisa energized sawise 【tundha wektu pangayoman U12, U22】.

Kontrol giliran endhog (R1, R2)

  • Output R1/R2 minangka output timer universal, sanajan fungsi kasebut dirancang kanggo ngowahi endhog inkubator.

Fungsi Timer kanggo giliran endhog

  • Sajrone【Belok ngiwa R1 wektu U31】, tampilan LILYTECH ZL-7801D-Pengontrol Kelembapan-lan-Suhu-anjir (3), R1 energized, R2 deenergized.
  • Sajrone【Belok tengen R2 wektu U33】, tampilanLILYTECH ZL-7801D-Pengontrol Kelembapan-lan-Suhu-anjir (3) , R1 deenergized, R2 energized.
  • Siji belokan endhog = siji ngiwa + siji ngiwa nengen. Counter giliran endhog ngitung kaping giliran endhog lengkap.
  • Yen 【Egg turn times U34】= 0, endhog turn timer ora bakal mandheg.
  • Yen 【Egg turn times U34】> 0, endhog turn timer bakal mandheg (mandheg endhog ngowahi) sawise nilai counter tekan U34, LILYTECH ZL-7801D-Pengontrol Kelembapan-lan-Suhu-anjir (3)lanLILYTECH ZL-7801D-Pengontrol Kelembapan-lan-Suhu-anjir (4) , kedhep.

Priksa endhog turn counter nilai.

  • Pencet 【S】lan【▼】 bebarengan, nampilake "Cnt" + "***" sajrone 2 detik. "***" minangka nilai counter.

Mungkasi lan miwiti maneh timer giliran endhog, endhog giliran counter reset

  • Tetep 【▲】lan 【▼】 nandhang sungkowo bebarengan kanggo 2 detik mandheg utawa miwiti timer giliran endhog.
  • Nalika endhog nguripake timer mandheg LILYTECH ZL-7801D-Pengontrol Kelembapan-lan-Suhu-anjir (3)lan LILYTECH ZL-7801D-Pengontrol Kelembapan-lan-Suhu-anjir (4)kedip-kedip.
  • Nalika wiwit saka status mandeg, endhog giliran counter ngreset menyang nul.

Egg turn counter reset sawise daya diwenehake

  • Yen【Reset endhog turn counter sawise daya diwenehake U35】= 0, counter bakal ngreset menyang nol sawise daya diwenehake.
  • Yen【Reset endhog turn counter sawise daya diwenehake U35】= 1, counter bakal tetep sawise daya diwenehake.

Manual ngowahi endhog

  • Tetep 【▲】 nandhang sungkowo sajrone 3 detik. Miwiti ngiwa, tampilanLILYTECH ZL-7801D-Pengontrol Kelembapan-lan-Suhu-anjir (3), R1 energized, R2 de-energized.
  • Tetep 【▼】 nandhang sungkowo sajrone 3 detik. Miwiti ngowahi tengen, tampilanLILYTECH ZL-7801D-Pengontrol Kelembapan-lan-Suhu-anjir (4), R1 de-energized, R2 energized.

Output R4

  • Output R4 sacara universal multifungsi, sanajan dirancang kanggo penggemar kekeselen hawa inkubator.

Fungsi Timer

  • Sajrone 【Timer R4 ing wektu U41】, R4 energized. Sajrone 【Waktu mati R4 U43】, R4 deenergized.
  • Fungsi pangayoman suhu utawa kelembapan sing dhuwur
    • Deleng: Kontrol -> Kontrol suhu -> Proteksi suhu dhuwur,
      • Kontrol -> Kontrol Kelembapan -> Perlindhungan kelembapan sing dhuwur.

Output R6

  • Output R6 multifungsi. Iki minangka output sing nguwatirake, utawa kanggo nyopir penggemar kekeselen hawa inkubator.

Fungsi weker

  • Deleng: Kontrol -> Kontrol suhu -> Weker suhu,
    • Kontrol -> Kontrol Kelembapan -> Weker Kelembapan.
  • Fungsi pangayoman suhu utawa kelembapan sing dhuwur
    • Deleng: Kontrol -> Kontrol suhu -> Proteksi suhu dhuwur,
      • Kontrol -> Kontrol Kelembapan -> Perlindhungan kelembapan sing dhuwur.

Sensor

Sensor suhu

Nalika sensor suhu gagal, tampilan blinking "Et". Kontroler bakal nggunakake data suhu saka sensor kelembapan. Iku luwih apik kanggo ngganti suhu sanalika bisa. Nalika sensor suhu lan sensor asor gagal, kontrol suhu mandheg, lan R3 tetep de-energized. Kontrol timer terus mlaku.

Sensor asor

Nalika sensor asor gagal, tampilan blinks "Eh". Kontrol asor mandheg, lan R5 tetep de-energized. Kontrol timer terus mlaku.

Mulihake menyang set pabrik.

Tansah 〖P〗lan〖▲〗nandhang sungkowo bebarengan sajrone 3 detik, "UnL" ditampilake. Banjur pencet 〖▼〗kaping pindho, lan kabeh paramèter bakal dipulihake menyang set pabrik, kalebu sandhi (ndeleng kolom tabel kode Parameter "Pabrik set").

Pènget

  1. Aja kabel nalika daya diwenehake.
  2. Spesifikasi kanggo beban yaiku kanggo beban resistensi murni.
    • Nalika nyopir beban kapasitif utawa induktif, kayata 100 watt ac-dc, bohlam pijar, disaranake nggunakake relay penengah, SSR input 220Vac, utawa kontaktor magnetik.
  3. Kerusakan kakehan ora ana ing garansi.

Instalasi

  1. Lebokake controller menyang bolongan.LILYTECH ZL-7801D-Pengontrol Kelembapan-lan-Suhu-anjir (5)
  2. Geser krenjang kanggo ndandani piranti (langkah loro)LILYTECH ZL-7801D-Pengontrol Kelembapan-lan-Suhu-anjir (6)

manungsa waé

  1. Kabel listrik kudu dimanipulasi dening tukang listrik sing wis disertifikasi.
  2. Sambungake miturut diagram kabel listrik. Sambungan sing salah bakal ngrusak piranti.
  3. Nggawe tata letak bundel sensor bebarengan karo bundel sumber daya.
  4. Aja kerja ing lingkungan medan listrik-magnetik sing erosif, teles, lan kuwat.
  5. Piranti iki wis dipriksa kanthi lengkap sadurunge dikirim. Wektu babar pisan siji taun, dadamagey salah panggunaan, kayata sambungan salah, ora dijamin.

Wiring Diagram

LILYTECH ZL-7801D-Pengontrol Kelembapan-lan-Suhu-anjir (7)

Dokumen / Sumber Daya

LILYTECH ZL-7801D Kelembapan lan Pengontrol Suhu [pdf] Manual Pamilik
ZL-7801D Kelembapan lan Pengontrol Suhu, ZL-7801D, Kelembapan lan Pengontrol Suhu, Pengontrol Suhu, Pengontrol

Referensi

Ninggalake komentar

Alamat email sampeyan ora bakal diterbitake. Kolom sing dibutuhake ditandhani *