Intesis INBACMEB0600000 MS-TP Server Gateway
M-BUS kanggo BACnet/IP & MS/TP Server Gateway
Nomer Item: INBACMEB0600000
Integrate any M-Bus device with a BACnet BMS or any BACnet IP or BACnet MS/TP controller. This integration aims to make M-Bus devices, their registers, and resources accessible from a BACnet-based control system or device as if they were a part of the BACnet system and vice versa.
Fitur lan keuntungan
Support for both BACnet/IP and BACnet MS/TP
The gateway supports both BACnet/IP and BACnet MS/TP protocols.
Commissioning-friendly approach with Intesis MAPS Templates can be imported and reused as often as needed, significantly reducing commissioning me.
- Configura on through IP (Console) port
Configura on can be carried out through the gateway’s IP (Console) port. - Konverter level M-Bus sing dipasang
An M-Bus level converter is embedded in the gateway, so no external one is required. - Integrasi gampang karo Intesis MAPS
The integration process is quickly and easily managed using the Intesis MAPS configura on tool. - Configura on tool and gateway automatic updates
Konfigurasi Intesis MAPS ing alat lan firmware gateway bisa nampa nganyari otomatis. - Deteksi meter otomatis lan ndhaptar panemuan
A scan function is available for automatic identification of M-Bus devices and register discovery.
BACnet Advanced features – calendars, schedules…BACnet’s advanced features, such as calendars, trend logs, schedules, and more, are available.
Umum
Umum | |
Jembar Net (mm) | 88 |
Dhuwur Net (mm) | 90 |
Ambane Net (mm) | 58 |
Bobot Net (g) | 159 |
Jembaré dikemas (mm) | 127 |
Dhuwur dikemas (mm) | 86 |
Kedalaman Paket (mm) | 140 |
Bobot Paket (g) | 184 |
Suhu Operasi °C Min | 0 |
Suhu Operasi °C Maks | 60 |
Suhu Panyimpenan °C Min | -30 |
Suhu Panyimpenan °C Maks | 60 |
Konsumsi Daya (W) | 13 |
Vol inputtage (V) | 24VDC +/-10%. |
Konektor Daya | 3-kutub |
Konfigurasi | MAPS Intesis |
Kapasitas | Nganti 60 meter. |
Ketentuan Instalasi | Gerbang iki dirancang kanggo dipasang ing njero pager. Yen unit dipasang ing njaba pager, pancegahan kudu ditindakake kanggo nyegah discharge elektrostatik menyang unit kasebut. Nalika nggarap pager (contone, nggawe pangaturan, nyetel switch, lsp.), pancegahan anti-statis sing khas kudu ditindakake sadurunge ndemek unit kasebut. |
Isi Pangiriman | Intesis Gateway, Manual Instalasi, Kabel Konfigurasi USB. |
Umum | |
Ora Klebu (ing pangiriman) | Sumber daya ora klebu. |
Pemasangan | DIN ril mount (krenjang klebu), Wall mount |
Material Omah | Plastik |
Garansi (taun) | 3 taun |
Packaging Material | Karton |
Identifikasi lan Status | |
ID produk | INBACMEB0600000 |
Negara Asal | Spanyol |
Kode HS | 8517620000 |
Nomer Klasifikasi Kontrol Ekspor (ECCN) | EAR99 |
Fitur Fisik | |
Konektor / Input / Output | Sumber daya, MBUS, Ethernet, USB port konsol, panyimpenan USB, EIA-485. |
Indikator LED | Status gateway lan komunikasi. |
DIP & Rotary Ngalih | Konfigurasi port serial EIA-485. |
Katrangan baterei | Mangan Dioxide Lithium tombol baterei. |
Sertifikasi lan Standar | |
Klasifikasi ETIM | EC001604 |
Kategori WEEE | IT lan peralatan telekomunikasi |
Gunakake Case
FAQ
- P: Apa sumber daya kalebu ing pangiriman?
A: No, the power supply is not included. You will need to source the power supply separately. - P: Apa gateway bisa dikonfigurasi liwat port IP (Console)?
A: Yes, configuration can be carried out through the gateway’s IP (Console) port.
Dokumen / Sumber Daya
![]() |
Intesis INBACMEB0600000 MS-TP Server Gateway [pdf] Manual Pamilik INBACMEB0600000, INBACMEB0600000 MS-TP Server Gateway, INBACMEB0600000, MS-TP Server Gateway, Server Gateway, Gateway |