RCW-360 Suhu lan Kelembapan Data Logger
“
Spesifikasi:
- Product Name: RCW-Pro 4G/WiFi
- Functions: Real-time monitoring, alarm, data recording, data
uploading, large screen display - Platform: Elitech iCold Platform – new.i-elitech.com
- Usage: Temperature and humidity monitoring in various
industri
Pandhuan panggunaan produk:
1. Fitur:
The product offers features such as real-time monitoring, alarm
functions, data recording, and large screen display.
2. Antarmuka:
Refer to the provided figure for the different components of the
product interface.
3. Pilihan Model:
The product model is RCW-Pro. Choose probe models based on the
required specifications as listed in the table.
4. Normal Operations:
- Setting Recording Intervals: Adjust normal recording, alarm
recording, normal upload, and alarm upload intervals. - Battery Life: Ensure the battery life is not less than the
durasi tartamtu.
5. Maximum and Minimum Values:
Short press the Menu key to view maximum and minimum values in
data sing direkam.
6. Viewing Records and Upload Intervals:
Access the Record and Upload Interval page to adjust settings
liwat APP.
7. Informasi piranti:
Check device information by pressing the Menu button to view
details like model, sensor version, GUID, IMEI, etc.
8. Adding Devices to the Platform:
Follow instructions in the Elitech iCold manual to add devices
to the platform using the APP or WEB klien.
Pitakonan sing Sering Ditakoni (FAQ):
Q: What type of sensors can be used with the RCW-Pro
monitor?
A: The monitor supports various sensors including digital
temperature and humidity sensors, analog to digital sensors, and
carbon dioxide sensors.
Q: How can I adjust the recording intervals?
A: You can adjust normal recording, alarm recording, normal
upload, and alarm upload intervals through the settings on the
device or via the APP.
“`
RCW- Pro 4G/WiFi
MANUAL PENGGUNA
Platform Elitech iCold: new.i-elitech.com
Produk iki minangka monitor Internet of Things nirkabel, nyedhiyakake fungsi kaya ngawasi wektu nyata, weker, ngrekam data, ngunggah data, tampilan layar gedhe, lan liya-liyane saka suhu lan kelembapan ing titik ngawasi. Bebarengan karo platform lan APP "Elitech iCold", bisa mujudake fungsi kayata data remot viewIng, query data sajarah, push weker remot, etc. Kang digunakake digunakake ing pangan, medicine, catering, warehousing internasional lan industri logistik.
1. Fitur
The product is suitable for various occasions, including warehouse, refrigerated storage, refrigerator car, shade cabinet, medicine cabinet, refrigerator lab, etc; Compact size, fashionable appearance, magnetic card tray design, easy installation; Large TFT color screen display, rich in content; Built-in rechargeable lithium battery enables long-time real-time data upload after power cut; Built-in sound-light alarm device can realize local alarm; Automatic screen-on/off; Supports up to channels, each channel supports a variety of pluggable probe types, probe types see the selection list.
2. Antarmuka
Gambar: Sensor botol gel
External probe SIM card interface( G Version) Charging indicator External probe
On/off button Charging interface Alarm status indicator “Menu” button
1
Magnetic card tray External Probe Interface Screen External Probe Interface
3. Model Selection List Collection Host:RCW- Pro. Tips:The specific host model is subject to the actual product;
Model probe: model probe konvensional ditampilake ing tabel ing ngisor iki:
Jenis probe
Tunggal
Dwi
suhu suhu
Suhu botol gel
Suhu lan asor
Suhu ultra kurang
kurang
dhuwur
Konsentrasi Konsentrasi
CO
CO
Model TD X-TE-R TD X-TDE-R TD X-TE(GLE)-R TD X-THE-R PT IIC-TLE-R SCD X-CO E STC X-CO E
kabel
Meter
Meter
Meter
Meter
Meter
Meter
Meter
Titik
siji
loro
siji
suhu
temperature temperature temperature probe and
probe
probe
probe
probe kelembaban
Siji suhu
probe
CO
CO
Konsentrasi Konsentrasi
Akurasi Range
– ~ °C ± . °C
T: – ~ °C
H: ~
RH
T: ± . °C, H: ± RH
– ~ °C ± . °C(- ~ °C) ± °C(- ~ °C)
± °C(Others)
~ ppm
±( reading)
~ vol
±( reading)
Sensor type Digital temperature and humidity sensor, Digital temperature sensor Analog to digital sensor Carbon Dioxide Sensor
Antarmuka sensor
. mm four section headphone interface, using I C communication mode
Note: . The specific sersor type is subject to the actual product. . The host does not come standard with probes. Please choose probes according to actual needs, and each channel can adapt to the above types of probes.
1. Power input: V/ A (DC), Type-C. 2. Temperature display resolution: . °C. 3. Humidity display resolution: . RH. 4. Number of offline recording groups: , . 5. Data storage mode: circular storage. 6. Record, upload interval and alarm interval:
Normal recording interval: minutes ~ hours allowed, Default minutes. Alarm recording interval: minutes ~ hours allowed, Default minutes. Normal upload interval: minutes ~ hours allowed, Default minutes. Alarm upload interval: minutes ~ hours allowed, Default minutes.
7. Battery life: Not less than Not less than
days (@ °C, good network environment, upload interval : minutes) days (@ °C, good network environment, upload interval : minutes)
8. Indicator light: alarm indicator, charging indicator. 9. Screen: TFT color screen. 10. Buttons: power on/off, menu. 11. Alarm buzzer: alarm occurs, sounding for minute. 12. Communication: G(can fall back to G),WIFI. 13. Location mode: LBS GPS(optional). 14. Alarm modes: local alarm and cloud alarm. 15. Waterproof grade: IP . 16. Working environment: – ~ °C, ~ RH (non condensing). 17.Specification and dimension: x x mm.
2
1. Installing and removing the probe Turn off the device and securely install the sensor to the headphone connector. To removing the sensor, please turn it off first and then unplug the sensor. 2. Charging Connect to the power adapter via USB cable. When charging, the charging indicator flashes, when it is fully charged, the charging indecator is always on. 3. Power on/off Press and hold the on/off button for seconds to turn on or off the device. Start recording data according to the recording interval after turn on, and report data according to the upload interval. Stop recording after turn off. 4. Real time data
Networking signal icon: Connect to the base station and display a signal bar. If the device networking is abnormal, an “X” will be displayed in the upper left corner of the signal. Channel identification: Represented by CH or CH , indicating the probe data corresponding to channel or for the current data. Real time temperature or humidity: Supports °C or °F display. If the platform turns off the probe, the corresponding position will display “OFF”. Upper and lower alarm limits: The data below the lower limit will be displayed in blue, and the data above the upper limit will be displayed in red. Number of data not uploaded: Displays the number of recorded but not uploaded data. Battery icon: Four bar battery indicator. When charging, the battery indicator flashes and remains on when fully charged. When the battery level is below , it is displayed in red. Time and date * When both channels are connected with probes, the CH and CH channel data automatically switches display within second cycle.
3
5. Maximum and Minimum Short press the “Menu” key to enter the “Maximum and Minimum” page, as shown in the following figure. Count the maximum and minimum values in the recorded data. CH A and CH B represent the two collected values of channel or , corresponding to sensor shutdown or single temperature probe. The B data displays “-~-“.
6. Viewrekaman lan interval upload Pencet cendhak tombol "Menu" kanggo ngetik kaca "Rekam lan Upload Interval", kaya sing ditampilake ing gambar ing ngisor iki, sing bisa disetel liwat APP.
7. View informasi piranti Pencet tombol "Menu" kanggo ngetik kaca "Informasi Piranti", kaya sing ditampilake ing gambar ing ngisor iki. Sampeyan bisa takon model, Sensor, versi, GUID, IMEI, kertu SIM ICCID (mung kanggo versi Wi-Fi)
8. Nambahake piranti menyang platform lan operasi dhasar Nambahake decices kanggo platform lan operasi, waca "IV Elitech iCold".
4
Platform Elitech iCold Cloud ndhukung rong cara kanggo nambah lan ngatur piranti: APP utawa WEB klien. Ing ngisor iki utamane ngenalake metode APP. WEB client can log in to new.i-elitech.com for operation.
1. Download and Install APP Please scan the QR code on the cover of the manual or search Elitech iCold APP Store or Google play to download Elitech App.
2. Account registration and APP Login Open the APP, in the login page, as shown in Figure , follow the prompts, enter the verification information, and click “Login”After entering the APP, select ” New “.
PS: a. If you have not an account, please click on “Register” in the login page, as shown in Figure ,
follow the prompts and enter verification information to complete account registration. b. If you forget the password, click “Forget password” to find password as shown in Figure .
Miturut pandhuan kanggo ngrampungake verifikasi lan ngerteni sandhi.
Gambar
Gambar
Gambar
5
3. Tambah Piranti
1. Klik ” ” ing pojok tengen ndhuwur 2. Klik ” ” ing pojok tengen ndhuwur, pindai kode QR utawa ketik GUID maneh ing piranti, banjur isi
ing jeneng piranti banjur pilih zona wektu. 3. Klik "", piranti ditambahake.
1
2
3
Tip: If the device shows offline after being added to the platform, first check the network icon and offline records on the device. If everything is normal, please wait for a few minutes or restart the device before turning it on. The device uploads data according to the set reporting cycle; If the device is offline for a long time, please check if the SIM card is overdue. Ultimately unable to resolve, please call the service hotline for consultation.
4. Jaringan distribusi WIFI (versi WIFI mung)
. Press the “Menu” key briefly to enter the “device Information” page. . Press and hold the “Menu” key, and a Bluetooth icon ” “will appear in the upper left corner of the device . Use the app to distribute the network with this device via Bluetooth, as shown in the following figures ~
6
5. Configure probe type
When using the device for the first time or changing the probe type, it is necessary to reconfigure the probe, as shown in Figure and Figure for operation; Operation method: Log in to the APP select the device to be changed select “Parameter Configuration” select “User Parameters” select the corresponding probe model based on the actual selected probe type and channel click “SET”.
Gambar 4
Gambar 5
Note: ( ) After reconfiguring the probe type, it is necessary to wait for an upload cycle to synchronize
the probe type to the device, or the device can be restarted to synchronize immediately. ( ) Replace the probe. Due to the time difference between replacing the probe and configuring it,
bisa uga ana data sing salah ing dhaptar data.
6. Manajemen piranti Klik ing piranti ing kaca utama APP kanggo ngetik kaca related Manajemen piranti. Sampeyan bisa view informasi piranti, ngganti jeneng piranti, view dhaptar data, nyetel wates ndhuwur lan ngisor weker, ngrekam / upload interval, ngatur push weker, view peta, laporan ekspor, lan operasi liyane.
7
Kanggo fungsi liyane, Mangga mlebu ing Elitech iCold Platform: new.i-elitech.com. Data gratis & layanan platform lanjutan bakal diaktifake sawise piranti pisanan didaftar ing platform Elitech. Sawise wektu percobaan, pelanggan kudu ngisi daya piranti kanthi ngrujuk menyang manual operasi.
8
V1.3
Dokumen / Sumber Daya
![]() |
Elitech RCW-360 Temperature and Humidity Data Logger [pdf] Manual pangguna RCW- Pro, TD X-TE-R, TD X-TDE-R, TD X-TE GLE -R, TD X-THE-R, PT IIC-TLE-R, SCD X-CO E, STC X-CO E, RCW-360 Temperature and Humidity Data Logger, RCW-360, Temperature and Humidity Data Logger, and Humidity Data Logger, Humidity Data Logger, Data Logger |