Pambuka
This manual provides detailed instructions for the installation, operation, and maintenance of the Garosa DDS529MR Single Phase Electric Energy Meter. This device is designed for measuring active energy in single-phase AC power systems. It features an LCD digital display with backlight, RS485 communication, and displays power, voltage, current, power factor, frequency, and rotation.
Informasi Safety
- Instalasi lan pangopènan mung kudu ditindakake dening personel sing mumpuni.
- Ensure the power supply is disconnected before any installation or wiring work.
- Do not operate the meter in environments with excessive moisture, dust, or corrosive gases.
- Verify all connections are secure and correct according to the wiring diagram to prevent damage or electric shock.
- The meter is designed for indoor use only.
Produk Overview
The DDS529MR energy meter is a compact device for accurate energy measurement. Key features include a clear LCD display, RS485 communication for data integration, and a standard DIN rail mounting for easy installation.

Gambar 1: Ngarep view of the DDS529MR energy meter with labeled components.
- A: Jeneng produk
- B: Electronic Display (LCD)
- C: Battery Display (if applicable)
- D: Nomer Model
- E: IEC Certificate Mark
- F: Product Parameters (e.g., 230V, 5(80)A, 50Hz, 1000imp/kWh)
- G: Indikator Daya LED
- H: Pulse Indicator LED
- I: Address / Baud Rate / Parity Modification, Switch Voltage/Current/Charge Display (via TURN/SET buttons)
- J: Jeneng merek
- K: Setting Button (SET)

Gambar 2: Close-up view of the LCD digital display with backlight.
Spesifikasi
| Paramèter | Nilai |
|---|---|
| Model | DDS529MR |
| Tingkat Akurasi | 1 |
| Tipe Tampilan | LCD kanthi Lampu Backlight |
| Ngukur Rentang Energi | 0.0-99999.0 kWh |
| Power Supply | AC |
| Output Voltage | 230 V AC |
| Dinilai Voltage | 230 V AC |
| Nomer Fase | Fase Tunggal |
| Frekuensi pulsa | 1000 imp / kWh |
| Rated Saiki | 5A |
| Arus maksimum | 80A |
| ukuran | Kira-kira 100 x 35 x 65mm (3.9 x 1.4 x 2.6 inci) |
| Instalasi | Rel DIN 35mm |
| Komunikasi | RS485 (MODBUS-RTU) |
| Bobot Barang | 210 g |

Gambar 3: Dimensions of the DDS529MR energy meter.
Setup lan Instalasi
Pemasangan
The DDS529MR energy meter is designed for standard 35mm DIN rail installation. Ensure the DIN rail is securely mounted in a suitable enclosure or panel.
- Align the meter's DIN rail clip with the DIN rail.
- Press the meter firmly onto the rail until it clicks into place.
- Verify the meter is securely fastened and does not wobble.

Gambar 4: mburi view nuduhake mekanisme pemasangan rel DIN.
Wiring Diagram
Refer to the following diagram for correct wiring connections. Ensure all power is disconnected before wiring.

Gambar 5: Wiring diagram for the DDS529MR energy meter, including power and RS485 connections.
- Terminal 1 & 2: Live (L) and Neutral (N) input for power supply.
- Terminal 3 & 4: Live (L) and Neutral (N) output for load.
- Terminal 21 & 20: Pulse output (SO+ and SO-).
- Terminals A & B (RS485): Data communication lines for RS485 (MODBUS-RTU).
Connect the main power supply to the input terminals (L and N). Connect the load to the output terminals (L and N). For RS485 communication, connect the A and B terminals to your RS485 network.
Instruksi Operasi
Power On
Once correctly wired and mounted, switch on the main power supply. The LCD display will illuminate, and the power indicator LED (G in Figure 1) will light up.
Tampilan Navigasi
The meter features a rotating display of various parameters. Use the NGABUK button to manually cycle through the displayed values:
- Total Energi Aktif (kWh)
- Wektu nyata Voltage (V)
- Real-time Current (A)
- Real-time Active Power (W)
- Faktor Tenaga (PF)
- Frekuensi (Hz)
The display will automatically rotate through these parameters at regular intervals. Pressing the NGABUK button allows for manual advancement to the next parameter.
Komunikasi RS485
The DDS529MR supports RS485 communication using the MODBUS-RTU protocol. This allows for remote reading of energy data and other parameters. Refer to the MODBUS protocol documentation for detailed register addresses and communication settings.
Ing SET button (K in Figure 1) is typically used for configuring communication parameters such as baud rate and address, or for resetting certain values. Consult the full technical datasheet for specific programming instructions if available.
Pangopènan
- Reresik: Gunakna kain alus lan garing kanggo ngresiki njaba meter. Aja nggunakake pembersih utawa pelarut sing abrasif.
- Pemriksaan: Periodically inspect the wiring connections for tightness and signs of wear or damage.
- Lingkungan: Priksa manawa lingkungan operasi tetep ana ing kisaran suhu lan kelembapan sing ditemtokake supaya umur meter luwih dawa.
- Ora ana bagean sing bisa dilayani pangguna: The meter contains no user-serviceable parts. Do not attempt to open or repair the device.
Ngatasi masalah
| Masalah | Kemungkinan Penyebab | Solusi |
|---|---|---|
| Tampilan kosong | No power supply; incorrect wiring; internal fault. | Check power connections and ensure power is on. Verify wiring according to the diagram. If problem persists, contact support. |
| Wacan sing salah | Incorrect wiring; meter not calibrated; external interference. | Double-check all wiring. Ensure the meter is installed correctly for single-phase measurement. If readings are consistently off, contact support. |
| Gagal komunikasi RS485 | Incorrect wiring of A/B lines; wrong baud rate/address; software configuration issue. | Verify RS485 wiring. Check baud rate, parity, and address settings on both the meter and the communication device. Consult MODBUS protocol documentation. |
| Pulse indicator not flashing | No load connected; very low power consumption; internal fault. | Ensure a load is connected and drawing power. The pulse rate is 1000 imp/kWh, so for very low loads, flashes may be infrequent. |
Warranty lan Dhukungan
Garosa products are manufactured to high-quality standards. For warranty information, please refer to the specific terms provided at the time of purchase or contact your vendor. For technical support or inquiries, please reach out to the Garosa customer service department or your local distributor.