1. Pambuka
The Joy-it DPM8605 is a highly versatile programmable buck power supply designed for laboratory and industrial applications. It features both constant voltage (CV) and constant current (CC) operating modes, providing precise control over power output. Equipped with a TTL interface, this power supply allows for convenient remote control and configuration via computer software, enhancing its utility in automated test setups and experimental environments. An optional wireless remote control (model 352551) is available for extended operational flexibility, offering control from up to 10 meters without obstructions.
2. Fitur Produk
- Programmable buck power supply with constant voltage (CV) lan mode saiki konstan (CC).
- Lebokake input voltage sawetara: 10V kanggo 75V.
- Output sing bisa diatur voltage: 0V kanggo 60V.
- Adjustable output current: 0A to 5A.
- Maximum output power: 300 Watts.
- High resolution for voltage (10 mV) and current (1 mA) settings.
- TTL interface for computer control and software integration.
- Optional wireless remote control capability (remote sold separately).
- Clear digital display for voltage lan wacan saiki.
3. Spesifikasi Teknis
| Paramèter | Nilai |
|---|---|
| Antarmuka | TTL (RS-232) |
| Vol inputtage Pasokan | 10 - 75 V |
| Output Voltage Range | 0 - 60 V |
| Output Range Saiki | 0 - 5 A |
| Maks. Daya Output | 300 Watt |
| Voltage Resolusi | 10 mV |
| Resolusi saiki | 1 mA |
| Sisa Ripple | <50 mVpp |
| Wektu Respon | <50 ms |
| Akurasi Tampilan (Voltage) | 10 mV |
| Akurasi Tampilan (Saiki) | 1 mA |
| Suhu operasi | -1 °C nganti 45 °C |
| Ukuran (L x W x H) | 11.2 x 13.1 x 5.5 cm |
| Bobot | 0.36 kg |
4. Pandhuan Safety
Kanggo njamin operasi sing aman lan nyegah kerusakan utawa ciloko ing piranti, mangga tindakake pandhuan keamanan ing ngisor iki:
- Tansah nyambungake sumber daya menyang stopkontak grounded.
- Aja operate piranti ing teles utawa damp kahanan.
- Priksa manawa ventilasi sing tepat kanggo nyegah overheating. Aja ngalangi bukaan ventilasi.
- Aja ngluwihi volume input maksimumtage (75V) or output power (300W).
- Before making any connections or disconnections, ensure the power supply is turned off and disconnected from the main power source.
- Aja short-circuiting terminal output.
- Only qualified personnel should attempt to service or repair the device.
- Keep the device away from flammable materials and explosive environments.
5. Setup
Follow these steps to set up your DPM8605 power supply:
- Mbukak kemasan: Carefully remove the DPM8605 from its packaging and inspect it for any signs of damage.
- Panggonan: Place the power supply on a stable, flat surface with adequate ventilation space around it. Ensure it is not exposed to direct sunlight, excessive dust, or vibrations.
- Sambungan Daya Input: Connect a suitable DC power source (10V to 75V) to the input terminals labeled ING+ lan ING-. Observe correct polarity.
- Output Load Connection: Connect your load to the output terminals labeled OUT+ lan metu-. Ensure the load's voltage and current requirements are within the DPM8605's specifications.
- RS-232 Connection (Optional): For computer control, connect a compatible RS-232 cable from the power supply's TTL interface to your computer. Install the necessary software and drivers as provided by Joy-it.

Gambar 1: Ngarep view of the DPM8605 showing the display and control buttons. The display shows "V" for voltage and "A" for current, along with numerical readouts. Buttons for "SET", arrow keys, and "OK" are visible below the display. Input and output terminals are on the sides.
6. Instruksi Operasi
6.1. Operasi dhasar
- Daya On/Off: Use the ON/OFF switch located on the side of the unit to power the device on or off.
- Setelan Voltage lan Saiki:
- Tekan ing SET tombol kanggo mlebu mode setelan parameter.
- Gunakake tombol panah (▲ / ▼) to navigate between voltage lan setelan saiki.
- Use the left/right arrow buttons to select the digit to adjust.
- Use the up/down arrow buttons to change the value of the selected digit.
- Pencet OK to confirm the setting and exit parameter setting mode.
- Pancet VoltagMode e (CV) lan Arus Konstan (CC): The device automatically switches between CV and CC modes depending on the load and the set voltagwatesan e/saiki.
- When operating in CV mode, the output voltage is maintained at the set value, and the current varies with the load. The CV indicator LED will be lit.
- When operating in CC mode, the output current is maintained at the set value, and the voltage varies with the load. This occurs when the load resistance is too low for the set voltage, causing the current to reach its set limit. The CC indicator LED will be lit.
6.2. Remote Control via TTL Interface (RS-232)
The DPM8605 can be controlled remotely via its TTL (RS-232) interface. This allows for integration into automated systems or control from a computer using dedicated software.
- Ensure the RS-232 cable is securely connected between the power supply and your computer.
- Install the official Joy-it software and drivers for the DPM8605. Refer to the software's documentation for installation and usage instructions.
- Through the software, you can set voltage, current, monitor output, and configure other parameters.

Gambar 2: Angled view of the DPM8605, highlighting the ventilation grilles on the side for heat dissipation and the terminal blocks for connections.
7. Pangopènan
Proper maintenance ensures the longevity and reliable operation of your DPM8605 power supply:
- Reresik: Regularly clean the exterior of the device with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure no liquids enter the device.
- Ventilasi: Keep the ventilation openings clear of dust and obstructions to ensure proper airflow and prevent overheating.
- Panyimpenan: Yen ora digunakake kanggo wektu sing suwe, simpen sumber daya ing papan sing adhem lan garing, adoh saka sinar srengenge langsung lan suhu sing ekstrem.
- Pemriksaan: Periodically inspect cables and connections for any signs of wear or damage. Replace damaged components immediately.
8. Ngatasi masalah
| Masalah | Kemungkinan Penyebab | Solusi |
|---|---|---|
| Piranti ora urip. | No input power; incorrect input voltage; power switch off. | Check input power source and connections. Ensure input voltage is within 10-75V. Verify the ON/OFF switch is in the 'ON' position. |
| Ora output voltage / saiki | Output disabled; incorrect settings; open circuit in load. | Ensure output is enabled (if applicable via software). Check set voltage/current limits. Verify load connections are secure and not open-circuited. |
| Output voltage/current is unstable. | Poor connections; excessive load; interference. | Check all input and output connections for looseness. Ensure load is within specified limits. Relocate device away from strong electromagnetic interference. |
| Overheating. | Blocked ventilation; excessive ambient temperature; prolonged high load. | Ensure ventilation grilles are clear. Operate within specified temperature range (-1°C to 45°C). Reduce load or allow for cooling periods. |
| RS-232 communication failure. | Incorrect cable; driver issues; software configuration. | Verify correct RS-232 cable. Reinstall drivers. Check software communication settings (COM port, baud rate). |
9. Warranty lan Dhukungan
Joy-it products are manufactured to high quality standards. For specific warranty terms and conditions, please refer to the documentation provided at the time of purchase or contact your retailer. In case of technical issues or questions not covered in this manual, please contact Joy-it customer support or your authorized dealer for assistance. Ensure you have your product model number (DPM8605) and purchase details ready when seeking support.