Model kalebu:
T1SAK3F4
Kit 4-Lawang kanthi Output Gabungan Kit sing dirakit kanthi lengkap kalebu:
- Enclosure Trove1 karo backplane TSA1 Altronix / SALTO
– (1) eFlow6NB – Power Supply/Charger
– (1) ACM4 – Pengontrol Daya Akses Fused
– (1) VR6 – Voltage Regulator
- (1) PDS8 - Modul Distribusi Daya Input Ganda

T2SAK7F8
8 Kit Pintu karo Output Gabungan The kanthi kit dirakit kalebu:
- Enclosure Trove2 karo backplane TSA2 Altronix / SALTO
– (1) eFlow104NB – Power Supply/Charger
– (1) ACM8 – Pengontrol Daya Akses Fused
– (1) VR6 – Voltage Regulator
- (1) PDS8 - Modul Distribusi Daya Input Ganda

T2SAK75F12
Kit 12-Lawang kanthi Output Gabungan Kit sing dirakit kanthi lengkap kalebu:
- Enclosure Trove2 karo backplane TSA2 Altronix / SALTO
– (1) eFlow104NB – Power Supply/Charger
– (1) eFlow102NB – Power Supply/Charger
– (1) ACM8 – Pengontrol Daya Akses Fused
– (1) ACM4 – Pengontrol Daya Akses Fused
- (1) PDS8 - Modul Distribusi Daya Input Ganda

Kabeh komponen kit Trove iki UL Listed minangka sub-assemblies.
Mangga deleng Pandhuan Instalasi Sub-Majelis sing cocog kanggo informasi luwih lengkap.

Guide Instalasi

Kabeh merek dagang sing kadhaptar minangka properti saka sing nduweni.
Pdt. TSAK032919

Perusahaan Instalasi: _______________________ Jeneng Perwakilan Layanan: __________________
Alamat: ___________________________ No. Telpon: ___________________________

Swaraview:

Kit Altronix Trove SALTO wis dirakit lan kasusun saka pager / backplane Trove1SA1 utawa Trove2SA2 kanthi sumber daya / pangisi daya lan sub-assembly Altronix sing diinstal ing pabrik. Kit iki uga nampung macem-macem kombinasi modul SALTO nganti rolas (12) lawang ing siji pager.

Bagan konfigurasi:

Instruksi Instalasi:

Cara kabel kudu sesuai karo Kode Listrik Nasional / NFPA 70 / ANSI, lan kabeh kode lokal lan panguwasa sing duwe yurisdiksi.
Produk kasebut mung ditrapake kanggo panggunaan njero ruangan.

  1. Copot backplane (s) saka pager. Aja mbuwang hardware.
  2. Tandhani lan predrill bolongan ing tembok kanggo baris munggah karo telung keyholes ndhuwur ing pager. Pasang telung fasteners ndhuwur lan ngawut-awut ing tembok karo kepala meneng protruding. Selehake bolongan tombol ndhuwur pager liwat telung sekrup ndhuwur, tingkat, lan aman. Tandhani posisi telung bolongan ngisor. Copot pager. Pengeboran bolongan ngisor lan pasang telung fasteners. Selehake bolongan tombol ndhuwur pager liwat telung sekrup ndhuwur. Pasang telung ngawut-awut ngisor lan priksa manawa kanggo ngencengi kabeh ngawut-awut.
  3. Gunung kalebu UL Listed tampngalih er (Altronix Model TS112 utawa padha) ing lokasi sing dikarepake, ngelawan nggeser. Geser tamper ngalih krenjang menyang pojok pager kira-kira 2 "saka sisih tengen (Fig. 1, pg. 2). Sambungake tampngalih kabel menyang input Panel Kontrol Akses utawa piranti laporan UL Listed sing cocog. Kanggo ngaktifake sinyal weker mbukak lawang pager.
  4.  Pasang modul SALTO menyang backplane TSA2, deleng pg. 3, 4, 5.
  5. Deleng Pandhuan Instalasi Pasokan Daya / Pangisi daya eFlow eFlow6NB, eFlow102NB, eFlow104NB, lan Pandhuan Instalasi Sub-Majelis sing cocog kanggo ACM4, ACM8, PDS8, VR6 kanggo instruksi instalasi luwih lanjut.

Hardware:

Altronix T2SAK7F8 Akses Trove lan Integrasi Daya - anjir 2

Altronix T2SAK7F8 Akses Trove lan Integrasi Daya - anjir 1

T1SAK3F4: Konfigurasi Modul SALTO:

  1. Cepet spacer menyang konfigurasi pena logam (A) saka backplane (Fig. 2, pg. 3).
  2. Posisi modul SALTO liwat spacer sing cocog lan pasang kanthi nggunakake sekrup kepala telusur (kasedhiya) (Fig. 2a, pg. 3).
  3. Pasang backplane menyang pager kanthi hardware.

Bagan Posisi Kontrol Akses kanggo Model Ing ngisor iki:

SALTO Akses Controller Pemasangan Pem
CU42E0, CU4200 utawa CU4EB8 A

Altronix T2SAK7F8 Akses Trove lan Integrasi Daya - anjir 3

T2SAK7F8: Konfigurasi Modul SALTO:

  1. Cepet spacer menyang konfigurasi pena logam (A) saka backplane (Fig. 3, pg. 4).
  2. Posisi modul SALTO liwat spacer sing cocog lan pasang kanthi nggunakake sekrup kepala telusur (kasedhiya) (Fig. 3a, pg. 4).
  3. Pasang backplane menyang pager kanthi hardware.

Bagan Posisi Kontrol Akses kanggo Model Ing ngisor iki:

SALTO Akses Controller Pemasangan Pem
CU42E0, CU4200 utawa CU4EB8 A

Altronix T2SAK7F8 Akses Trove lan Integrasi Daya - anjir 4

T2SAK75F12: Konfigurasi Modul SALTO:

  1. Cepet spacer menyang konfigurasi pena logam (A) saka backplane (Fig. 4, pg. 5).
  2. Posisi modul SALTO liwat spacer sing cocog lan pasang kanthi nggunakake sekrup kepala telusur (kasedhiya) (Fig. 4a, pg. 5).
  3. Pasang backplane menyang pager kanthi hardware.

Bagan Posisi Kontrol Akses kanggo Model Ing ngisor iki:

SALTO Akses Controller Pemasangan Pem
CU42E0, CU4200 utawa CU4EB8 A

Altronix T2SAK7F8 Akses Trove lan Integrasi Daya - anjir 5

Pasokan / Pengisi Daya eFlow bisa Dikontrol lan Dipantau nalika Nglaporake Daya / Diagnostik saka Endi wae liwat Jaringan…

Logo Altronix 3

Altronix T2SAK7F8 Akses Trove lan Integrasi Daya - anjir 6

LINQ2 – Modul Komunikasi Jaringan
LINQ2 nyedhiyakake akses IP remot menyang data wektu-nyata saka sumber daya / pangisi daya eFlow kanggo mbantu sistem tetep munggah lan mlaku ing tingkat optimal. Iku nggampangake instalasi lan nyetel-up cepet lan gampang, nyilikake downtime sistem, lan ngilangake telpon layanan rasah, kang mbantu nyuda Total Biaya Kepemilikan (TCO) - uga nggawe sumber anyar saka Recurring Monthly Revenue (RMR).

Fitur:

- UL kadhaptar ing AS lan Kanada.
– Kontrol lokal utawa remot nganti (2) loro output daya Altronix eFlow liwat LAN lan/utawa WAN.
- Monitor diagnostik wektu nyata: output DC voltage, output saiki, AC & baterei status / layanan, owah-owahan negara pemicu input, owah-owahan negara output lan suhu unit.
- Kontrol akses lan manajemen pangguna: Watesi maca / nulis, Watesi pangguna kanggo sumber daya tartamtu
- Loro (2) jaringan integral sing dikontrol Formulir "C" Relay.
- Telung (3) pemicu input sing bisa diprogram: Kontrol relay lan sumber daya liwat sumber hardware eksternal.
- Kabar Email lan Windows Dashboard
- Log acara nglacak riwayat.
- Lapisan Soket Aman (SSL).
- Programmable liwat USB utawa web browser - kalebu piranti lunak operasi lan kabel USB 6 ft.

LINQ2 Mounts Nang sembarang Trove Enclosure

Altronix T2SAK7F8 Akses Trove lan Integrasi Daya - anjir 7

T1SAK3F4 Ukuran Enclosure (H x W x D):
18" x 14.5" x 4.625" (457mm x 368mm x 118mm)

Altronix T2SAK7F8 Akses Trove lan Integrasi Daya - anjir 8

Dimensi Enclosure T2SAK7F8 lan T2SAK75F12 (H x W x D):
27.25" x 21.75" x 6.5" (692.15mm x 552.5mm x 165.1mm)

Altronix T2SAK7F8 Akses Trove lan Integrasi Daya - anjir 9

Logo Altronix 4

Altronix ora tanggung jawab kanggo kesalahan tipografi.
140 58th Street, Brooklyn, New York 11220 USA | telpon: 718-567-8181 | fax: 718-567-9056
web situs: www.altronix.com | e-mail: info@altronix.com | Garansi seumur hidup