Logo Altronix NetWay4BT NetWay BT Series PoE Managed Midspan Solution

Altronix NetWay4BT NetWay BT Series PoE Ngatur Solusi Midspan

Produk Altronix NetWay4BT NetWay BT Series PoE Managed Midspan Solution

Swaraview

Altronix NetWay4BT / NetWay8BT Networked Managed Midspan nyedhiyakake PoE / PoE + / Hi PoE (nganti 90W) daya saben port, lan pass data ing 10/100/1000 Mbps ing jarak nganti 100m. Fitur uga kalebu pangisi daya baterei integral kanggo aplikasi sing mbutuhake serep lan semat Teknologi LINQ kanggo ngawasi, ngontrol, lan laporan daya lan diagnostik saka ngendi wae.

Fitur

Daftar Agensi:

  • UL 60950-1 Teknologi Informasi

prabotan.

  • Sistem Kontrol Akses UL 294.
    ANSI/UL 294 7th Ed. Kontrol Akses
    Tingkat Kinerja: Serangan Ngancurake - I;
    Ketahanan - II; Keamanan Line - I; Daya Stand-by - II.
  • CE European Conformity.

Input:

  • 115VAC, 60Hz, 5.5A utawa 230VAC, 50/60Hz, 3.0A.

daya:

  • Unit pasokan output PoE voltage (55V) lan nganti
    90W maks. daya lengkap saben port.
    Daya total NetWay4BT: 360W / 6.6A.
    Daya total NetWay8BT: 480W / 8.8A.
  • IEEE 802.3af, IEEE, 802.3at lan
    IEEE802.3bt tundhuk.
  • Proteksi sirkuit cendhak.

Ethernet:

  • Papat (4) utawa wolung (8) port kanggo kamera / piranti pinggiran liwat ethernet.
  • Jinis kabel: 4-pasangan CAT5e lan luwih dhuwur.
  • Kacepetan: 10/100/1000 Mbps.

Fungsi:

  • Deteksi otomatis lan pangayoman saka kamera non-PoE lawas / piranti pinggiran.

Gawe serep baterei:

  • Pangisi daya baterei sing dibangun (kabel baterei dipasang ing rak opsional - RE2).
  • Ngalih otomatis menyang baterei stand-by nalika AC gagal.

Teknologi LINQ:

  • SSL (Secure Socket Layer) enkripsi keamanan.
  • Keamanan tingkat pangguna.
  • Manajemen IP bawaan ngidini nyetel lan ngawasi kamera jarak jauh.
  • Nyedhiyakake akses lokal lan / utawa remot menyang informasi kritis liwat LAN / WAN
  • Notifikasi Tandha Dashboard Email lan Windows nglaporake diagnostik wektu nyata.
  • Log acara nglacak riwayat.

Aksesoris:
RE2:

  • Rack Mount Battery Enclosure nampung nganti papat (4) baterei 12VDC / 7AH.

Pandhuan Instalasi

Cara pengkabelan kudu sesuai karo Kode Listrik Nasional (ANSI/NFPA70), kode lokal, lan panguwasa sing duwe yurisdiksi. NetWay4BT / NetWay8BT unit ora dimaksudaké kanggo disambungake menyang ndadékaké tanduran njaba. Produk kasebut mung kanggo panggunaan njero ruangan lan kudu dipasang ing papan sing dilindhungi. Yen krenjang baterei dicopot, unit kasebut kudu dipasang ing area akses sing diwatesi (Fig. 1b, pg. 3).Altronix NetWay4BT NetWay BT Series PoE Managed Midspan Solution gambar 1

  1. Masang soyo tambah krenjang kanggo NetWay4BT / NetWay8BT unit kanggo rak utawa wall Mount instalasi (Fig. 5 utawa 6, pg. 8).
    Affix bantalan karet kanggo NetWay4BT / NetWay8BT kanggo instalasi beting (Fig. 7, pg. 8).
  2. Amanake unit ing rak utawa ing tembok, utawa pasang unit ing rak kaya sing dikarepake.
    Cathetan: Faktor ing ngisor iki kudu digatekake nalika nginstal unit pemasangan rak iki:
    • Unit kasebut kudu dipasang ing papan sing suhu sekitar maksimal ora ngluwihi 104ºF (40ºC).
    • Ati-ati kanggo mesthekake yen ana aliran udara sing cukup ing saubengé unit lan ora ana alangan sing ngalangi.
    • Nalika masang unit ing rak, ngati-ati supaya ora ngemot sing ora rata sing bisa nyebabake kahanan sing mbebayani.
  3. Pasang kabel garis AC grounded (kalebu) menyang konektor IEC 320 saka unit NetWay4BT / NetWay8BT (Fig. 2g, pg. 4). Tancepake unit menyang soket ground ground sing dipercaya. Nalika nggunakake sawetara unit, jumlah saka ratings plate jeneng individu ngirim ora ngluwihi rating sirkuit sumber.
    Aja nyambung menyang wadhah sing dikontrol dening saklar.
  4. Sambungake kabel terstruktur saka port sing ditandhani [IN] ing NetWay4BT/NetWay8BT menyang input sing cocog saka switch ethernet utawa server video
    (Gambar 2b, kaca 4, Gambar 3, kaca 6).
    Cathetan: Kabeh kabel lan kabel kudu UL Listed lan / utawa kabel dikenali cocok kanggo aplikasi sing.
  5. Sambungake kabel kabentuk saka port ditandhani [OUT] ing NetWay4BT / NetWay8BT kanggo kamera cecek PoE / piranti pinggiran (Fig. 2a, pg. 4, Fig. 3, pg. 6).
  6. Nalika nggunakake baterei stand-by dibutuhake, padha kudu disegel asam timbal utawa jinis gel. Sambungake papat (4) baterei 12VDC ing seri kanggo terminal ditandhani [+ BAT –] (Fig. 2h, pg. 4), kasebut kanthi teliti, mirsani polaritas. Wigati: Nalika baterei ora digunakake mundhut saka AC bakal kasil mundhut saka output voltage.
    Waca Tabel Spesifikasi Stand-by (pg. 4).Altronix NetWay4BT NetWay BT Series PoE Managed Midspan Solution gambar 2
  • 2a OUT1-4 (NetWay4BT), OUT 1-8 (NetWay8BT):
    Kabel terstruktur menyang kamera sing cocog karo PoE / piranti pinggiran.
  • 2b IN 1-4 (NetWay4BT), IN 1-8 (NetWay8BT): Kabel terstruktur kanggo switch ethernet utawa server video. 2c LED(s) 1-4 (NetWay4BT),1-8 (NetWay8BT): LED status port.
  • Reset 2d: Mulihake unit menyang setelan pabrik.
  • 2e Port USB: Kanggo nyetel setelan IP sacara lokal.
  • 2f Port Ethernet: Digunakake kanggo ngatur / ngawasi output lan nyetel setelan IP Jaringan.
  • 2g Konektor IEC 320: 115/230VAC (kabel kabel grounded).
  • 2h Pangisi daya baterei internal: Ngisi daya baterei stand-by kanggo aplikasi sing mbutuhake serep.
    Baterei bisa diinstal ing sembarang UL, U / R dirating pager, kayata Altronix rak gunung kandang baterei RE2 (Fig. 3, pg. 5).

Spesifikasi Stand-by

(total saiki ditampilake):

Output 30 Menit Siyaga Saiki
Baterei 48V/7AH 6.7A
Baterei 48V/12AH 8.3A

* 48V serep nggunakake 4 (papat) 12V baterei ing seri.

Altronix NetWay4BT NetWay BT Series PoE Managed Midspan Solution gambar 3Lampu kilat kanthi simbol panah ing segitiga padha karo tujuane kanggo menehi tandha marang pangguna babagan anané VOL DANGEROUS sing terisolasi.TAGE ing enclosure produk sing ukurane cukup kanggo nggawe kejut listrik.
Altronix NetWay4BT NetWay BT Series PoE Managed Midspan Solution gambar 4Tanda seru ing segi telu padha karo tujuane kanggo menehi tandha marang pangguna babagan instruksi operasi lan pangopènan (servis) sing penting ing literatur sing ngiringi piranti.
AWAS: Kanggo nyuda resiko kejut listrik, aja mbukak tutup. Ora ana bagean sing bisa digunakake pangguna ing njero.
Rujuk layanan menyang personel layanan sing mumpuni.

Spesifikasi Teknis

Paramèter Katrangan
Nomer Pelabuhan NetWay4BT: Sekawan (4) Port PoE/PoE+/Hi PoE (10/100/1000 Mbps).

NetWay8BT: Wolung (8) Port PoE/PoE+/Hi PoE (10/100/1000 Mbps).

Daya Output NetWay4BT: total 360W | NetWay8BT: 480W
Kebutuhan Daya Input 115VAC, 60Hz, 5.5A utawa 230VAC, 50/60Hz, 3.0A.
Indikator LED Status Port.
 

Kondisi Lingkungan

Suhu Sekitar Operasi: 0ºC nganti 49ºC (32ºF nganti 120ºF). Kelembapan Relatif: 85%, +/- 5%.

Suhu Panyimpenan: – 20ºC nganti 70ºC (– 4ºF nganti 158ºF).

Dhuwur Operasi: Nganti 2,000m.

 

Bobot (kira-kira)

NetWay4BT NetWay8BT
Bobot produk: 6.06 lb. (2.75 kg).

Bobot Pengiriman: 8.0 lb. (3.63 kg).

Bobot produk: 6.06 lb. (2.75 kg).

Bobot Pengiriman: 8.0 lb. (3.63 kg).

NetWay8BT Aplikasi KhasAltronix NetWay4BT NetWay BT Series PoE Managed Midspan Solution gambar 5 Altronix NetWay4BT NetWay BT Series PoE Managed Midspan Solution gambar 6Jinis Kabel, Total Daya Piranti, Data lan Jarak Daya

Tipe Kabel Konsumsi Daya Total Maks. Jarak Data Maks. Jarak Daya
CAT5e 15W 100m 846m
CAT5e 30W 100m 423m
CAT5e 60W 100m 211m
CAT5e 75W 100m 185m
CAT5e 90W 100m 158m

Cathetan: Wiring gauge sing luwih dhuwur bakal ngidini jarak sing luwih dawa.

Konfigurasi NetWay4BT / NetWay8BT kanggo Sambungan Jaringan

Mangga manawa kanggo ngunjungi altronix.com kanggo firmware paling anyar lan instruksi instalasi

Setelan Default Pabrik

  • IP Sadurungé: 192.168.168.168
  • Jeneng pangguna: admin
  • Sandi: admin
  1. Setel alamat IP statis kanggo laptop sing bakal digunakake kanggo program menyang alamat IP jaringan sing padha karo NetWay4BT/NetWay8BT. Alamat standar NetWay8BT yaiku 192.168.168.168,
  2. Sambungake siji ujung kabel jaringan menyang jack jaringan ing NetWay4BT / NetWay8BT lan liyane menyang sambungan jaringan laptop.
  3. Bukak browser ing komputer lan ketik "192.168.168.168" ing baris alamat. Kothak dialog Authentication Required bakal katon njaluk jeneng pangguna lan sandhi. Ketik nilai gawan ing kene. Klik tombol kanthi label Log In.
  4. Kaca status NetWay4BT/NetWay8BT bakal katon. Klik ing tab sing dilabeli Setelan Jaringan. Iki bakal mbukak layar Setelan Jaringan. Ing layar iki alamat MAC saka modul NetWay4BT/NetWay8BT bakal ditemokake bebarengan karo Setelan Jaringan lan Setelan Email.

Setelan Jaringan

Ing kolom Metode Alamat IP, pilih metode sing bakal dipikolehi Alamat IP kanggo NetWay4BT/NetWay8BT (STATIC utawa DHCP), banjur tindakake langkah sing cocog.

statis:

  1. Alamat IP: Ketik alamat IP sing diwenehake menyang NetWay4BT/NetWay8BT dening administrator jaringan.
  2. Subnet Mask: Ketik Subnet jaringan.
  3. Gateway: Ketik gateway TCP/IP titik akses jaringan (router) sing digunakake (konfigurasi gateway dibutuhake kanggo nampa email kanthi bener saka piranti)
  4. Port HTTP: Ketik nomer port HTTP sing diwenehake menyang modul NetWay4BT/NetWay8BT dening administrator jaringan kanggo ngidini akses lan ngawasi remot. Setelan port mlebu standar yaiku 80.
    HTTP ora dienkripsi lan ora aman. Sanajan HTTP bisa digunakake kanggo akses remot, dianjurake utamane kanggo nggunakake sambungan LAN.
  5. Port HTTPS: Ketik nomer port HTTPS sing diwenehake menyang modul NetWay4BT/NetWay8BT dening administrator jaringan kanggo ngidini akses lan ngawasi remot. Setelan port mlebu standar yaiku 443. Dienkripsi lan luwih aman, HTTPS dianjurake banget kanggo akses remot.
  6. Klik tombol kanthi label Kirim Setelan Jaringan. Kothak dialog bakal nampilake "Setelan jaringan anyar bakal ditrapake sawise server diwiwiti maneh". Klik OK.

DHCP:

  1. Sawise milih DHCP ing kolom Metode Alamat IP klik tombol kanthi label Kirim Setelan Jaringan. Kothak dialog bakal nampilake "Setelan jaringan anyar bakal ditrapake sawise server diwiwiti maneh". Klik OK. Sabanjure, klik tombol kanthi label Reboot Server. Sawise rebooting NetWay4BT/NetWay8BT bakal disetel ing mode DHCP. Alamat IP bakal diutus dening router nalika NetWay4BT / NetWay8BT
    disambungake menyang jaringan. Disaranake supaya Alamat IP sing ditugasake dilindhungi undhang-undhang kanggo njamin akses terus (ndeleng administrator jaringan).
  2. Subnet Mask: Nalika operasi ing DHCP, router bakal nemtokake nilai subnet mask.
  3. Gateway: Ketik gateway TCP/IP saka titik akses jaringan (router) sing digunakake.
  4. Port HTTP: Ketik nomer port HTTP sing diwenehake menyang modul NetWay8BT dening administrator jaringan kanggo ngidini akses lan ngawasi remot. Setelan port mlebu standar yaiku 80.
    HTTP ora dienkripsi lan ora aman. Sanajan HTTP bisa digunakake kanggo akses remot, dianjurake utamane kanggo nggunakake sambungan LAN.

Secure Network Setup (HTTPS):

Kanggo nyiyapake HTTPS kanggo Sambungan Jaringan Aman, Sertifikat lan Kunci sing Sah kudu digunakake. Sertifikat lan Kunci kudu ana ing format ".PEM". Sertifikasi Mandiri mung kudu digunakake kanggo tujuan tes amarga ora ana bukti asli sing ditindakake. Ing mode Self-Certified, sambungan kasebut isih bakal nyatakake yen ora aman. Cara ngunggah Sertifikat lan Kunci kanggo nyiyapake HTTPS:

  1. Bukak Tab Label "Keamanan"
  2. Pilih Tab Labeled "Email/SSL"
  3. Gulung menyang ngisor ing "Setelan SSL"
  4. Klik "Pilih Sertifikat"
  5. Telusuri banjur pilih Sertifikat sing bener kanggo diunggah saka server
  6. Klik "Select Key"
  7. Telusuri banjur pilih Kunci sing bener kanggo diunggah saka server
  8. Klik "Kirim Files”

Sawise Sertifikat lan Kunci diunggah kanthi sukses, sampeyan bisa nerusake nyetel HTTPS ing Setelan Jaringan.

  • Port HTTPS: Ketik nomer port HTTPS sing diwenehake menyang modul NetWay4BT/NetWay8BT dening administrator jaringan kanggo ngidini akses lan ngawasi remot. Setelan port mlebu standar yaiku 443. Dienkripsi lan luwih aman, HTTPS dianjurake banget kanggo akses remot.
  • Klik tombol sing diwenehi label Kirim Setelan Jaringan.
    Kothak dialog bakal nampilake "Setelan jaringan anyar bakal ditrapake sawise server urip maneh". Klik OK.

Pilihan Pemasangan

Pemasangan Rack Mount

  1. Copot lan discard pabrik diinstal ngawut-awut saka loro-lorone saka sasis rak (Fig. 5a).
  2. Instal krenjang soyo tambah (A) ing sisih kiwa lan tengen sasis rak nggunakake papat (4) ngawut-awut flat (B) (kalebu) (Fig. 5b).
  3. Selehake unit menyang posisi rak EIA 19 sing dikarepake lan aman nganggo sekrup sing dipasang (ora kalebu) (Fig. 5c).Altronix NetWay4BT NetWay BT Series PoE Managed Midspan Solution gambar 7

Pemasangan Wall Mount

  1. Pasang krenjang soyo tambah (A) ing sisih kiwa lan tengen sasis rak nggunakake papat (4) ngawut-awut flat (B) (kalebu) (Fig. 6a).
  2. Panggonan unit ing lokasi sing dipengini lan aman karo # 6 ukuran ngawut-awut utawa luwih gedhe (ora klebu) (Fig. 6b). Ati-ati: Sampeyan kudu nggawe manawa sekrup dipasang kanthi aman
    menyang balok nalika nginstal unit vertikal.Altronix NetWay4BT NetWay BT Series PoE Managed Midspan Solution gambar 8

Pemasangan Rak

  1. Posisi lan affix bantalan karet (C) (kalebu) ing saben sudhut ing ngisor unit (Fig. 7).
  2. Selehake unit ing lokasi sing dikarepake.Altronix NetWay4BT NetWay BT Series PoE Managed Midspan Solution gambar 9

Altronix ora tanggung jawab kanggo kesalahan tipografi. 140 58th Street, Brooklyn, New York 11220 USA | telpon: 718-567-8181 | fax: 718-567-9056
websitus: www.altronix.com | e-mail: info@altronix.com | Garansi seumur hidup

Dokumen / Sumber Daya

Altronix NetWay4BT NetWay BT Series PoE Ngatur Solusi Midspan [pdf] Pandhuan Instalasi
NetWay4BT, NetWay BT Series PoE Managed Midspan Solution, NetWay4BT NetWay BT Series PoE Managed Midspan Solution, Managed Midspan Solution, Midspan Solution

Referensi

Ninggalake komentar

Alamat email sampeyan ora bakal diterbitake. Kolom sing dibutuhake ditandhani *