Altronix MAXIMAL77F Maksimal F Series Dual Power Supply Akses Pengontrol Daya

Model Kalebu
Maksimal11F
- Sumber Daya 1:
12VDC @ 3.3A utawa 24VDC @ 3.6A. - Sumber Daya 2:
12VDC @ 3.3A utawa 24VDC @ 3.6A. - Nembelas (16) sekring dilindhungi output winates daya.
Maksimal33F
- Sumber Daya 1:
12VDC @ 5.3A utawa 24VDC @ 5.6A. - Sumber Daya 2:
12VDC @ 5.3A utawa 24VDC @ 5.6A. - Nembelas (16) sekring dilindhungi output non daya winates.
Maksimal55F
- Sumber Daya 1: 12VDC @ 9.3A.
- Sumber Daya 2: 12VDC @ 9.3A.
- Nembelas (16) sekring dilindhungi output non daya winates.
Maksimal75F
- Sumber Daya 1: 12VDC @ 9.3A.
- Sumber Daya 2: 24VDC @ 9.6A.
- Nembelas (16) sekring dilindhungi output non-daya winates.
Maksimal77F
- Sumber Daya 1: 24VDC @ 9.6A.
- Sumber Daya 2: 24VDC @ 9.6A.
- Nembelas (16) sekring dilindhungi output non-daya winates.
Seri MaximalF Swaraview
Pengontrol Daya Akses MaximalF nyebarake lan ngalih daya kanggo ngakses sistem kontrol lan aksesoris. Padha ngowahi input 120VAC 60Hz dadi nembelas (16) kontrol independen 12VDC utawa 24VDC output dilindhungi sekring. Output daya Gagal-Aman/Gagal-Aman iki bisa diowahi dadi kontak "C" sing garing. Output diaktifake dening sink kolektor mbukak utawa input pemicu garing biasane mbukak (NO) saka Sistem Kontrol Akses, Keypad, Tombol Push, REX PIR, lan sapiturute. Unit bakal ngarahake daya menyang macem-macem piranti hardware kontrol akses kalebu: Kunci Mag , Serangan Listrik, Pemegang Door Magnetik, lsp. Antarmuka FACP mbisakake Egress Darurat, Pemantauan Alarm, utawa bisa digunakake kanggo micu piranti tambahan liyane. Fitur pedhot weker geni bisa dipilih kanthi individu kanggo siji utawa kabeh saka nembelas (16) output. Kabeh peralatan interconnecting kudu UL Listed.
Bagan Konfigurasi Seri MaximalF
|
Nomer Model Altronix |
120VAC 60 Hz Input (saiki) |
Power Supply Papan Input Fuse Rating |
Papan Pasokan Daya Baterai Fuse Rating | Nominal DC Output Voltage Pilihan | Maksimum Supply Saiki kanggo Utama lan Aux. Output (Sumber Daya 1 / Sumber Daya 2), (A) | Output sing dilindhungi sekring | ACM8 Papan Input Fuse Rating | ACM8 Papan Output Fuse Rating | |||||||
| Sumber Daya 1 | Sumber Daya 2 | ||||||||||||||
| [DC] | [AUX] | [DC] | [AUX] | ||||||||||||
| Range Output 12VDC (V) | Range Output 24VDC (V) | Range Output 12VDC (V) | Range Output 24VDC (V) | Range Output 12VDC (V) | Range Output 24VDC (V) | Range Output 12VDC (V) | Range Output 24VDC (V) | ||||||||
|
Maksimal11F |
7A |
5A/ 250V |
7.5A/ 32V |
eFlow4NB | eFlow4NB | – |
16* |
10A/ 250V |
3.5A/ 250V |
||||||
| 10.1-
13.2 |
– | 10.05-
13.2 |
– | 10.1-
13.2 |
– | 10.05-
13.2 |
– | 3.3A +
3.3A |
|||||||
| 10.1-
13.2 |
– | 10.05-
13.2 |
– | – | 20.28-
26.4 |
– | 20.2-
26.4 |
3.3A +
3.6A |
|||||||
| – | 20.28-
26.4 |
– | 20.2-
26.4 |
– | 20.28-
26.4 |
– | 20.2-
26.4 |
3.6A +
3.6A |
|||||||
|
Maksimal33F |
7A |
5A/ 250V |
10A/ 32V |
eFlow6NB | eFlow6NB | – |
16 |
10A/ 250V |
3.5A/ 250V |
||||||
| 10.0-
13.2 |
– | 10.03-
13.2 |
– | 10.0-
13.2 |
– | 10.03-
13.2 |
– | 5.3A +
5.3A |
|||||||
| 10.0-
13.2 |
– | 10.03-
13.2 |
– | – | 20.19-
26.4 |
– | 20.19-
26.4 |
5.3A +
5.6A |
|||||||
| – | 20.19-
26.4 |
– | 20.19-
26.4 |
– | 20.19-
26.4 |
– | 20.19-
26.4 |
5.6A +
5.6A |
|||||||
|
Maksimal55F |
7A |
5A/ 250V |
15A/ 32V |
eFlow102NB | eFlow102NB |
9.3A + 9.3A |
16 |
10A/ 250V |
3.5A/ 250V |
||||||
| 10.03-
13.2 |
– | 10.03-
13.2 |
– | 10.03-
13.2 |
– | 10.03-
13.2 |
– | ||||||||
|
Maksimal75F |
8A |
5A/250V
(eFlow102NB) 6.3A/250V (eFlow104NB) |
15A/ 32V |
eFlow102NB | eFlow104NB |
9.3A + 9.6A |
16 |
10A/ 250V |
3.5A/ 250V |
||||||
| 10.03-
13.2 |
– | 10.03-
13.2 |
– | – | 20.17-
26.4 |
– | 20.28-
26.4 |
||||||||
|
Maksimal77F |
9A |
6.3A/250V |
15A/ 32V |
eFlow104NB | eFlow104NB |
9.6A + 9.6A |
16 |
10A/ 250V |
3.5A/ 250V |
||||||
| – | 20.17-
26.4 |
– | 20.28-
26.4 |
– | 20.17-
26.4 |
– | 20.28-
26.4 |
||||||||
Maksimal11F mung: Unit iki diklasifikasikaké minangka Kelas 2 Power-Limited stand alone power supply kanthi baterei siyaga lan cocok kanggo daya: sensor, lan piranti elektromekanis (contone, serangan lawang listrik).
Maksimal33F, Maksimal55F, Maksimal75F lan Maksimal77F: Output DC kanggo sumber daya iki ora winates daya. Yen output daya-winates dibutuhake ing aplikasi produk pungkasan, output DC saka sumber daya kudu disambungake menyang unit kontrol kapisah Listed utawa Papan aksesoris sing nyedhiyani output daya winates. Produk(e) sing nyedhiyakake output (e) winates daya kudu kadhaptar sing cocog kanggo aplikasi produk pungkasan tartamtu lan nganggo kabel sesuai karo instruksi instalasi produk. Cara kabel kelas 1, pamisahan sirkuit, lan enclosure sing dirating geni sing tepat kabeh kudu dianggep nalika nyambungake output DC saka sumber daya menyang piranti produk pungkasan. Output tambahan saka unit kasebut diwatesi daya.
Listings Agensi
Listings UL kanggo Instalasi US
UL 294* - UL Dhaptar kanggo Unit Sistem Kontrol Akses.
*ANSI/UL 294 7th Ed. Tingkat Kinerja Kontrol Akses:
Serangan ngrusak - I; Ketahanan - I; Keamanan Line - I; Daya Stand-by - II, III, IV.
Daftar UL kanggo Instalasi Kanada:
ULC-S319-05 - Peralatan Sistem Kontrol Akses Elektronik Kelas I.
CSA C22.2 No.205 - Peralatan Sinyal.
Sistem Kontrol Akses Elektronik ULC-S319-05 bakal ora valid amarga nggunakake tambahan, ekspansi, memori utawa modul liyane sing diprodhuksi dening pabrikan utawa pabrikan liyane.
Fitur Seri MaximalF
Modul Kontrol Daya Akses ACM8:
- Nembelas (16) kanthi mandiri micu output sing dikontrol. Pilihan Output:
a) Nembelas (16) output daya saring Gagal-Aman.
b) Nembelas (16) output daya saring Gagal-Aman.
c) Nembelas (16) mbentuk output relay "C" (dirating @ 5A/28VDC utawa VAC).
d) Sembarang kombinasi saka ndhuwur. - Nembelas (16) input pemicu Sistem Kontrol Akses. Pilihan pemicu input:
a) Nembelas (16) input pemicu garing biasane mbukak (NO).
b) Nembelas (16) input kolektor mbukak.
c) Sembarang kombinasi saka ndhuwur. - Nembelas (16) aux disaring sing ora diowahi. output daya (output dirating @ 2.5A).
- LED abang ing Papan ACM8 nuduhake output individu sing micu (relay energized).
- Pedhot Alarm Kebakaran (latching utawa non-latching) bisa dipilih kanthi individu kanggo kabeh utawa wolung (8) output. Pilihan pemicu input pedhot Alarm Kebakaran:
a) Biasane mbukak (NO) utawa biasane ditutup (NC) input pemicu garing.
b) Input pembalikan polaritas saka sirkuit sinyal FACP. - LED ijo ing papan ACM8 nuduhake pedhot FACP dipicu.
- Relay output FACP nuduhake yen input FACP dipicu (bentuk kontak "C" dirating @ 1A / 28VDC ora dievaluasi dening UL).
- eFlow Power Supply / Charger menehi daya umum kanggo Papan ACM8 (wiring pabrik) lan kabeh piranti kontrol akses disambungake (wiring lapangan).
- Sekring utama papan ACM8 dirating @ 10A. Sekring output dirating @ 3.5A.
Sumber Daya / Pengisi Daya eFlow: - Input: 120VAC, 60Hz.
- Kanggo output voltage lan sumber saiki deleng Bagan Konfigurasi seri MaximalF, pg. 3.
- Output Terbatas Daya Kelas 2 Tambahan dirating @ 1A (ora ngalih).
- Overvoltage pangayoman.
- Pangisi daya internal kanggo batere asam timbal utawa gel sing ditutup.
- Pangisian daya maksimum saiki 1.54A.
- Ngalih otomatis menyang baterei stand-by nalika AC gagal. Transfer menyang daya baterei siyaga langsung tanpa gangguan.
- Diawasi Fire Alarm pedhot (latching utawa non-latching) 10K EOL resistor. Makaryakke ing pemicu biasane mbukak (NO) utawa biasane ditutup (NC).
- Pengawasan gagal AC (bentuk kontak "C").
- Baterei gagal & pengawasan ngarsane (wangun "C" kontak).
- mateni daya kurang. Mateni terminal output DC yen baterei voltage mudhun ing ngisor 71-73% kanggo unit 12V lan 70-75% kanggo unit 24V (gumantung saka sumber daya). Ngalangi discharge baterei jero.
- Kanggo rating sekring deleng Bagan Konfigurasi seri MaximalF, pg. 3.
- LED Daya AC Hijau nuduhake 120VAC saiki.
- Indikator LED input AC lan output DC.
- Short circuit lan pangayoman kakehan.
- Enclosure nampung nganti papat (4) baterei 12VDC / 12AH.
Ukuran kandang (H x W x D): 26" x 19" x 6.25" (660.4mm x 482.6mm x 158.8mm).
Pandhuan Instalasi MaximalF
Cara pengkabelan kudu sesuai karo Kode Listrik Nasional / NFPA 70 / ANSI, Kode Listrik Kanada, Part I, Part II lan kabeh kode lan panguwasa lokal sing duwe yurisdiksi. Produk dimaksudake mung kanggo panggunaan njero ruangan.
- Diagnostik LED Papan Pasokan Daya (p. 7)
- Diagnostik LED Kontrol Daya Akses (p. 7)
- Papan Pasokan Daya Spesifikasi Baterei Stand-by (pg. 7)
- Identifikasi Terminal Papan Catu Daya (pg. 8)
- Identifikasi Terminal Pengontrol Daya Akses (pg. 8)
- Power Supply Papan Output Voltage Setelan (p. 9)
- Diagram Aplikasi Khas Pengontrol Daya Akses (pg. 9)
- FACP/Diagram Hook-up Pasokan Daya Opsional (p. 12)
- Pasang unit ing lokasi sing dikarepake. Tandhani lan predrill bolongan ing tembok kanggo baris munggah karo telung keyholes ndhuwur ing pager. Pasang telung fasteners ndhuwur lan ngawut-awut ing tembok karo kepala meneng protruding. Selehake keyholes ndhuwur pager liwat telung ngawut-awut ndhuwur, tingkat lan aman. Tandhani posisi telung bolongan ngisor. Copot pager. Pengeboran bolongan ngisor lan pasang telung fasteners. Selehake bolongan tombol ndhuwur pager liwat telung sekrup ndhuwur. Pasang telung ngawut-awut ngisor lan priksa manawa kanggo ngencengi kabeh ngawut-awut (Dimensi Enclosure, pg. 15).
- Sambungake daya AC unswitched (120VAC 60Hz) kanggo terminal ditandhani [L, N] (Fig. 3, pg. 10). Hijau "AC"
LED ing papan sumber daya bakal urip. Cahya iki bisa dideleng liwat lensa LED ing lawang pager. Gunakake 14 AWG utawa luwih gedhe kanggo kabeh sambungan daya. Kabel ijo sing aman timbal menyang lemah.
Supaya kabel daya winates kapisah saka non daya winates wiring.
Minimal 0.25 "spasi kudu diwenehake (Fig. 3, pg. 10).
AWAS: Aja ndemek bagean logam sing katon. Mateni daya sirkuit cabang sadurunge nginstal utawa nglayani peralatan. Ora ana bagean sing bisa digunakake pangguna ing njero. Rujuk instalasi lan servis menyang personel layanan sing mumpuni. - Pilih output DC sing dikarepake voltage dening nyetel SW1 posisi cocok ing Papan sumber daya (Maximal11F lan Maximal33F) (Fig. 1, pg. 9). Sumber daya maksimal55F disetel pabrik ing 12VDC.
Sumber daya Maximal77F disetel pabrik ing 24VDC. Maximal75F kasusun saka siji (1) papan catu daya sing disetel pabrik ing 12VDC, lan siji (1) papan catu daya sing disetel pabrik ing 24VDC. - Ukur output voltage saka unit sadurunge nyambungake piranti kanggo mesthekake operasi sing bener.
Vol ora cocog utawa dhuwurtage bakal ngrusak piranti kasebut. - Pilihan output (Gbr. 2, pg. 9):
Unit kasebut bakal nyedhiyakake enem belas (16) output daya sing diuripake, nembelas (16) output "C" sing garing, utawa kombinasi apa wae saka output daya sing diuripake lan output "C".
(a) Output Daya Ngalih sing Gagal Aman:
Kanggo operasi Gagal-Aman, sambungake input positif (+) saka piranti kontrol akses menyang terminal sing ditandhani [NC]. Sambungake input negatif (-) piranti kontrol akses menyang terminal sing ditandhani [COM].
(b) Output Daya Saklar Aman-Gagal:
Kanggo operasi Fail-Secure sambungake input positif (+) saka piranti kontrol akses menyang terminal
ditandhani [NO]. Sambungake input negatif (-) piranti kontrol akses menyang terminal sing ditandhani [COM].
(c) Output Formulir "C":
Nalika wangun "C" output dikarepake sekring output cocog (1-8) saben Papan ACM8 kudu dibusak. - Output Daya Tambahan ACM8 (ora ngalih):
Sambungake piranti kontrol akses sing mbutuhake daya konstan menyang terminal sing ditandhani [C] positif (+) lan [COM] negatif (-). Output bisa digunakake kanggo nyedhiyani daya kanggo maca kertu, keypads etc.
Output tambahan eFlow (ora ngalih):
Kanggo sambungan piranti tambahan output iki ora bakal kena pengaruh Low Power Disconnect utawa Fire Alarm
Antarmuka. Sambungake piranti menyang terminal sing ditandhani [+ AUX –] (Gbr. 3, pg. 10). - Pilihan pemicu input (Gbr. 2, pg. 9):
(a) Biasane mbukak pemicu input [NO]:
Input 1-8 diaktifake kanthi input sink kolektor sing biasane mbukak utawa mbukak. Sambungake output panel kontrol akses, keypad, tombol push, REX PIRs, lan sapiturute menyang terminal ditandhani [IN] lan [GND].
(b) Input Sink Kolektor Terbuka:
Sambungake panel kontrol akses mbukak kolektor sink positif (+) menyang terminal ditandhani [IN] lan negatif (-) kanggo terminal ditandhani [GND]. - Pilihan Antarmuka Alarm Kebakaran ACM8 (Gambar 5-9, pg. 12):
Pemicu input [NC] utawa biasane mbukak [NO] saka panel kontrol weker geni utawa input pembalikan polaritas saka sirkuit sinyal FACP bakal mengaruhi output sing dipilih. Kanggo ngaktifake FACP Disconnect kanggo output nguripake switch sing cocog [SW1-SW8] ing saben papan ACM8. Kanggo mateni FACP pedhot kanggo output nguripake saklar cocog (e) [SW1-SW8] ing saben Papan ACM8.
(a) Biasane mbukak input [NO]:
Kanggo non-latching hook-up deleng Fig. 6, pg. 12. Kanggo latching hook-up deleng Fig. 7, pg. 12.
(b) Input [NC] Biasane Ditutup:
Kanggo non-latching hook-up deleng Fig. 8, pg. 12. Kanggo latching hook-up deleng Fig. 9, pg. 12.
(c) Pemicu input Sirkuit Sinyal FACP:
Sambungake positif (+) lan negatif (-) saka output sirkuit sinyal FACP menyang terminal sing ditandhani [+ INP –]. Sambungake FACP EOL menyang terminal sing ditandhani [+ RET -] (polaritas dirujuk ing kondisi weker). Jumper dumunung ing jejere TRG LED kudu Cut (Fig. 6, pg. 12). - FACP Formulir garing "C" output (Ora dievaluasi dening UL) (Fig. 2b, pg. 9):
Kontak formulir "C" FACP bisa digunakake kanggo micu piranti pelapor utawa sinyal. Kontak kasebut ngalih marang pemicu input weker geni menyang papan ACM8. - Sambungan Baterei Stand-by (Gbr. 3, pg. 10):
Kanggo aplikasi Kontrol Akses AS, baterei opsional. Baterei dibutuhake kanggo instalasi Kanada (ULC-S319). Nalika baterei ora digunakake, mundhut saka AC bakal kasil mundhut saka output voltage. Nalika nggunakake baterei stand-by dikarepake, padha kudu asam timbal utawa jinis gel. Sambungake baterei menyang terminal sing ditandhani [– BAT +] (Gbr. 3, pg. 10). Gunakake rong (2) baterei 12VDC disambungake ing seri kanggo operasi 24VDC (baterei ndadékaké klebu). Gunakake baterei - baterei Casil CL1270 (12V / 7AH), CL12120 (12V / 12AH), CL12400 (12V / 40AH), CL12650 (12V / 65AH) utawa baterei BAZR2 lan BAZR8 sing diakoni UL kanthi rating sing cocog. - Output Pengawasan Baterei lan AC (Gbr. 3, pg. 10):
Sampeyan kudu nyambungake piranti laporan masalah pengawasan menyang output sing ditandhani [AC Fail, BAT Fail] output relay pengawas sing ditandhani [NC, C, NO] menyang piranti notifikasi visual sing cocog. Gunakake 22 AWG kanggo
18 AWG kanggo laporan AC Gagal & Kurang/Ora ana baterei. - Kanggo tundha laporan AC sajrone 2 jam, setel switch DIP [Tundha AC] menyang posisi OFF (Gambar 3, pg. 10).
Kanggo tundha laporan AC kanggo 1 min., Setel ngalih DIP [Tundha AC] menyang posisi ON (Fig. 3, pg. 10). - Pedhot Alarm Kebakaran (Gbr. 3, pg. 10):
Kanggo ngaktifake Fire Alarm Disconnect, atur switch DIP [Shutdown] menyang posisi ON.
Kanggo mateni Alarm Kebakaran Pedhot setel saklar DIP [Shutdown] menyang posisi OFF. - Pemasangan Tamper Ngalih (Gbr. 3a, pg. 10):
Gunung UL Listed tampngalih er (model Altronix TS112 utawa padha) ing ndhuwur pager. Geser ing
tamper ngalih krenjang menyang pojok pager kira-kira 2 "saka sisih tengen (Fig. 3a, pg. 10).
Nyambung tampngalih kabel menyang input Panel Kontrol Akses utawa piranti laporan UL Listed sing cocog. Kanggo ngaktifake sinyal weker mbukak lawang pager. - Multiple power supply inputs (Fig. 2, pg. 9) (Ora dievaluasi dening UL):
Nalika nggunakake sumber daya external Listed tambahan, jumper J1 lan J2 dumunung ing cocog Papan ACM8 kudu Cut (Fig. 2c, pg. 9 & Fig. 5, pg. 12). Sambungake sumber daya kontrol akses winates daya Kadhaptar eksternal menyang terminal sing ditandhani [– Control +] (Terminal iki sejajar karo terminal [– Power +]). Nalika nggunakake sumber daya DC, polaritas kudu diamati. Nalika nggunakake sumber daya AC, polaritas ora perlu diamati (Fig. 2d, pg. 9.) Kabeh sambungan kabel lapangan kudu digawe nggunakake ukuran cocok CM utawa FPL jacketed kabel (utawa sulih padha) (Fig. 4a, pg. 11) .
Pangopènan
Unit kudu dites paling ora sepisan taun kanggo operasi sing tepat kaya ing ngisor iki:
Supervision FACP: Kanggo mesthekake sambungan sing tepat lan operasi saka Fire Alarm pedhot hookup.
Mangga tindakake prosedur sing cocog ing ngisor iki:
Biasane Bukak Input: Nempatake cendhak antarane terminal ditandhani [T] lan [+ INP] bakal micu Fire Alarm Disconnect. Copot singkat kanggo ngreset.
Input Biasane Ditutup: Mbusak kabel saka terminal sing ditandhani [INP –] bakal micu Pedhot Alarm Kebakaran. Ganti kabel menyang terminal sing ditandhani [INP –] kanggo ngreset.
Input Sirkuit Sinyal FACP: Sampeyan kudu micu Sistem Alarm Kebakaran. Ing kabeh skenario ndhuwur bakal TRG LED ijo saka ACM8s madhangi. Kabeh output dipilih kanggo
Fire Alarm Disconnect will activate releasing locking devices.
Cathetan: Kabeh output [OUT 1] – [OUT 8] kudu ing kondisi normal (de-energized) sadurunge testing. Nalika unit dikonfigurasi kanggo Normally Open (Fig. 8, pg. 12) utawa Normally Closed (Fig. 10, pg. 12) operasi latching, perlu ngreset Fire Alarm Disconnect kanthi ngaktifake switch reset Normally Closed.
Output Voltage Test: Ing kondisi mbukak normal, DC output voltage kudu dipriksa kanggo vol sing tepattage tingkat (waca MaximalF seri Bagan Konfigurasi, pg. 3).
Test baterei: Ing kahanan mbukak normal priksa manawa baterei wis kebak, mriksa tartamtu voltage ing terminal baterei lan ing terminal Papan ditandhani [+ BAT –] kanggo mesthekake yen ana break ing kabel sambungan baterei.
Cathetan: Saiki pangisian daya maksimal yaiku 1.54A. Umur baterei sing dikarepake yaiku 5 taun; Nanging, dianjurake kanggo ngganti baterei ing 4 taun utawa kurang yen perlu.
Diagnostik LED Papan Pasokan Daya:
| Abang (DC) | Ijo (AC/AC1) | Status Pasokan Daya |
| ON | ON | Kondisi operasi normal. |
| ON | OFF | Mundhut AC. Baterei stand-by nyedhiyakake daya. |
| OFF | ON | Ora ana output DC. |
| OFF | OFF | Mundhut AC. Baterei kosong utawa ora ana stand-by. Ora ana output DC. |
| Abang (Kelawar) | Status baterei |
| ON | Kondisi operasi normal. |
| OFF | Baterei gagal / baterei sithik. |
Akses Power Controller LED Diagnostik
| LED | ON | OFF |
| LED 1- LED 8 (Abang) | Output relay (s) energized. | Output relay (s) de-energized. |
| Trg (Ijo) | Input FACP dipicu (kondisi weker). | FACP normal (kondisi non-alarm). |
Akses Power Controller LED Diagnostik
| Baterei | Maksimal11F | Maksimal33F | Maximal55F, Maximal75F, lan Maximal77F |
| 7AH | 30 Menit/4A* | 10 Menit/6A | 5 Menit/10A |
| 12AH | 35 Menit/4A* | 30 Menit/6A* | 30 Menit/10A* |
| 40AH | Luwih saka 4 Jam/4A* | Luwih saka 4 Jam/6A* | Luwih saka 2 Jam/10A* |
| 65AH | Luwih saka 4 Jam/4A* | Luwih saka 4 Jam/6A* | Luwih saka 4 Jam/10A* |
Mung konfigurasi iki bisa digunakake ing instalasi ULC-S319.
Identifikasi Terminal Papan Pasokan Daya
| Katrangan Terminal | Fungsi/Deskripsi |
| L, G, N | Sambungake 120VAC 60Hz menyang terminal iki: L kanggo panas, N kanggo netral. Aja nggunakake terminal sing ditandhani [G]. |
| + DC - | Pabrik disambungake menyang papan ACM8. |
| Pemicu EOL Diawasi | Fire Alarm Interface micu input saka singkat utawa FACP. Input pemicu bisa biasane mbukak, biasane ditutup saka sirkuit output FACP (input winates daya kelas 2) (Gambar 3, kaca 10). |
| Ora, GND RESET | Antarmuka FACP latching utawa non-latching (Kelas 2 winates daya) (Gambar 3, kaca 10). |
| + AUX- | Output winates daya Kelas Tambahan 2 dirating @ 1A (ora ngalih) (Gambar 3, kaca 10). |
| AC GAGAL NC, C, NO | Nuduhake mundhut daya AC, contone, nyambung menyang piranti sing bisa dirungokake utawa panel weker. Relay biasane diuripake nalika daya AC ana.
Rating kontak 1A @ 30VDC (Kelas 2 winates daya) (Gbr. 3, pg. 10). |
|
BAT GAGAL NC, C, NO |
Nuduhake kahanan baterei sithik, contone, nyambung menyang panel weker. Relay biasane diuripake nalika daya DC ana. Rating kontak 1A @ 30VDC.
Baterei sing dicopot dilaporake sajrone 5 menit. Sambungan maneh baterei dilaporake sajrone 1 menit (Watesan daya Kelas 2) (Gbr. 3, pg. 10). |
| + BAT— | Sambungan baterei stand-by.
Pangisian daya maksimal saiki 1.54A (ora winates daya) (Gbr. 3, pg. 10). |
Identifikasi Terminal Kontrol Daya Akses
| Katrangan Terminal | Fungsi/Deskripsi |
| - Daya + | 12VDC utawa 24VDC saka sumber daya / pangisi daya (pabrik disambungake). Terminal kasebut sejajar karo terminal [– Control +]. |
|
- Kontrol + |
Terminal iki sejajar karo terminal [– Power +]. Terminal-terminal kasebut bisa disambungake menyang sumber daya kontrol akses winates daya sing didhaptar eksternal kanggo nyedhiyakake daya operasi sing terisolasi kanggo piranti kasebut (Ora dievaluasi dening UL).
Jumper J1 lan J2 kudu dibusak. |
| PEMIMCU INPUT 1- INPUT 8 IN, GND | Saka input pemicu sink kolektor sing biasane mbukak lan / utawa mbukak (panyuwunan kanggo metu tombol, metu saka pir, lsp.) |
|
OUTPUT 1- OUTPUT 8 NC, C, NO, COM |
12VDC kanggo 24VDC pemicu kontrol output. Beban maksimal saben output yaiku 2.5A. |
| Maksimal11F: P/S 1 – 10.1-13.2VDC @ 3.3AP/S 2 – 10.1-13.2VDC @ 3.3A utawa P/S 1 – 20.28-26.4VDC @ 3.6AP/S 2 – 20.28-26.4VDC P / S 3.6 - 1-10.1VDC @ 13.2A lan P / S 3.3 - 2-20.28VDC @ 26.4A. | |
| Maksimal33F: P/S 1 – 10.0-13.2VDC @ 5.3AP/S 2 – 10.0-13.2VDC @ 5.3A utawa P/S 1 – 20.28-26.4VDC @ 5.6AP/S 2 – 20.28-26.4VDC P / S 5.6 - 1-10.0VDC @ 13.2A lan P / S 5.3 - 2-20.28VDC @ 26.4A. | |
| Maximal55F: P / S 1 - 10.03-13.2VDC @ 9.3A lan P / S 2 - 10.03-13.2VDC @ 9.3A. | |
| Maximal75F: P / S 1 - 10.03-13.2VDC @ 9.3A lan P / S 2 - 20.17-26.4VDC @ 9.6A. | |
| Maximal77F: P / S 1 - 20.17-26.4VDC @ 9.6A lan P / S 2 - 20.17-26.4VDC @ 9.6A. | |
| Gagal-Aman [NC positif (+) & COM Negatif (-)], Gagal-Aman [NO positif (+) & COM Negatif (-)], Auxiliary output [C positif (+) & COM Negatif (-)] ( Nalika nggunakake AC sumber daya polaritas ora kudu diamati), NC, C, NO ngowahi kanggo wangun garing "C" 5A 24VAC/VDC dirating output garing nalika sekring dibusak. Kontak sing ditampilake ing negara sing ora dipicu. | |
| ANTARA FACP T, + INPUT – | Fire Alarm Interface micu input saka FACP. Input pemicu bisa biasane mbukak, biasane ditutup saka output sirkuit sinyal FACP (Gambar 5-9, kaca 12). |
| ANTARA FACP NC, C, NO | Kontak relay Formulir "C" dirating @ 1A 28VDC kanggo laporan weker (ora dievaluasi dening UL). |
Power Supply Papan Output Voltage Setelan

Diagram Aplikasi Khas Pengontrol Daya Akses (kanggo saben ACM8)

AWAS: Nalika papan sumber daya disetel kanggo 12VDC nggunakake mung siji (1) 12VDC stand-by baterei.
Tetep kabel winates daya kapisah saka non-daya winates.
Gunakake spasi minimal 0.25″.
Baterei sing bisa diisi ulang 12AH minangka baterei paling gedhe sing bisa dipasang ing kandang iki. Enclosure baterei eksternal sing kadhaptar UL kudu digunakake yen nggunakake baterei 40AH utawa 65AH.
NEC Power-Limited Wiring Requirements
Wiring sirkuit winates daya lan non-daya kudu tetep dipisahake ing kabinet. Kabeh kabel sirkuit winates daya kudu tetep paling sethithik 0.25 "adoh saka kabel sirkuit non-daya winates. Salajengipun, kabeh wiring sirkuit winates daya lan kabel sirkuit non-daya-winates kudu mlebu lan metu saka kabinèt liwat conduits beda.
Salah sijine mantanample iki kapacak ing ngisor iki. Aplikasi khusus sampeyan mbutuhake knockout saluran sing beda kanggo digunakake. Sembarang knockout saluran bisa digunakake. Kanggo aplikasi daya-winates nggunakake conduit iku opsional. Kabeh sambungan kabel lapangan kudu digawe nggunakake ukuran cocok CM utawa kabel jaket FPL (utawa sulih padha).
Enclosure baterei UL Listed opsional kudu dipasang ing jejere sumber daya liwat metode kabel Kelas 1.
Kanggo instalasi Canadian nggunakake wiring shielded kanggo kabeh sambungan.
Cathetan: Deleng gambar nangani kabel ing ngisor iki kanggo cara sing bener kanggo nginstal kabel jaket CM utawa FPL (Fig. 4a).

Daya-winates kanggo Maximal11F.
Ora winates daya kanggo Maximal33F, Maximal55F,
Maximal75F, lan Maximal77F.
FACP Hook-Up Diagrams
Gambar 5
Hook-up opsional nggunakake rong (2) input sumber daya terisolasi (Mung ditrapake ing Maximal11F, ora dievaluasi dening UL):

Gambar 6
Input pembalikan polaritas saka output sirkuit sinyal FACP (polaritas dirujuk ing kondisi weker):

Gambar 7
Biasane Bukak: Input pemicu FACP Non-Latching:

Gambar 8
Biasane Bukak input pemicu FACP Latching kanthi ngreset: 
Gambar 9
Biasane Ditutup: Input pemicu FACP Non-Latching:

Gambar 10
Biasane Ditutup: Nempelake input pemicu FACP kanthi ngreset:

Ukuran Enclosure (H x W x D kira-kira):
26" x 19" x 6.25" (660.4mm x 482.6mm x 158.8mm)

Altronix ora tanggung jawab kanggo kesalahan tipografi.
140 58th Street, Brooklyn, New York 11220 USA | telpon: 718-567-8181 | fax: 718-567-9056
websitus: www.altronix.com | e-mail: info@altronix.com | Garansi seumur hidup
IIMaximal11F/33F/55F/75F/77F Series
eFlow Power Supply / Charger bisa Controlled lan ngawasi nalika Reporting
Daya/Diagnostik saka ngendi wae liwat Jaringan…
LINQ2 – Modul Komunikasi Jaringan
LINQ2 nyedhiyakake akses IP remot menyang data wektu-nyata saka sumber daya / pangisi daya eFlow kanggo mbantu sistem tetep munggah lan mlaku ing tingkat optimal. Iku nggampangake instalasi lan nyetel-up cepet lan gampang, nyilikake downtime sistem, lan ngilangake telpon layanan rasah, kang mbantu ngurangi Total Biaya Kepemilikan (TCO) - uga nggawe sumber anyar saka Ambalan Monthly Revenue (RMR).

Fitur
- UL Kadhaptar ing AS lan Kanada.
- Kontrol lokal utawa remot nganti (2) loro output daya Altronix eFlow liwat LAN lan/utawa WAN.
- Monitor diagnostik wektu nyata: DC output voltage, output saiki, AC & baterei status / layanan, owah-owahan negara pemicu input, owah-owahan negara output lan suhu unit.
- Kontrol akses lan manajemen pangguna: Watesi maca / nulis, Watesi pangguna kanggo sumber daya tartamtu
- Loro (2) jaringan integral kontrol Formulir "C" Relay.
- Telung (3) pemicu input sing bisa diprogram: Kontrol relay lan sumber daya liwat sumber hardware eksternal.
- Email lan Windows Dashboard kabar
- Log acara nglacak riwayat.
- Secure Socket Layer (SSL).
- Programmable liwat USB utawa web browser - kalebu piranti lunak operasi lan kabel USB 6 ft.
LINQ2 Mounts Nang sembarang MaximalF Enclosure

Maksimum11F/33F/55F/75F/77F Series Access Power Controllers (Fused) Pandhuan Instalasi
Dokumen / Sumber Daya
![]() |
Altronix MAXIMAL77F Maksimal F Series Dual Power Supply Akses Pengontrol Daya [pdf] Pandhuan Instalasi MAXIMAL77F, Maksimal F Series, Dual Power Access Access Power Controllers, MAXIMAL77F Maksimal F Series Dual Power Supply Akses Kontroler Daya, Maksimal F Series Dual Power Supply Akses Kontroler Daya, Power Supply Akses Kontroler Daya, Akses Power Controllers, Power Controllers, Controllers |