AKO CAMRegis Basic Owner’s Manual

AKO CAMRegis Basic Owner’s Manual

AKO-logo

AKO CAMRegis Basic

AKO-CAMRegis-Basic-product

Pènget

  • Unit kasebut kudu dipasang ing papan sing dilindhungi saka getaran, banyu lan gas korosif, ing ngendi suhu sekitar ora ngluwihi nilai sing dituduhake ing data teknis.
  • For the unit to operate correctly, use only the probes supplied by AKO. For the reading to be correct, the probe should be used in a place without heat influences apart from the temperature you want to me-asure or control.
  • Probe lan kabel kasebut ora kudu dipasang ing saluran bebarengan karo kabel daya, kontrol utawa feeder.
  • In the event of lengthening the NTC probe, always used shield cable and earth the mesh. In these cases, the maximum deviation will be 0.25 ºC from -40 ºC to +20 ºC (Maximum 1000 m with a minimum section of 0.5 mm2 ).
  • We recommend using AKO-15586 cable. Always disconnect the power supply to do the wiring.
  • The power circuit should be equipped with a switch marked as dis-connecting device of the equipment of at least 2 A, 230 V, situated near the appliance.
  • The power supply cable should be H05VV-F or H05V-K type. The gauge will depend on local regulations, but should in no case be less than 1 mm2 . The electrical installation should be carried out under pipe. Using the logger not observing the manufacturer’s instructions may alter the appliance safety requirements. Only probes supplied by AKO should be used for the appliance to operate correctly.

Instalasi

AKO-CAMRegis-Basic-product

DIMENSI

AKO-CAMRegis-Basic (9)

 Spesifikasi teknis

  • Power supply……………………………………………… 90-240 V~ 50/60Hz
  • Alarm relay…………………………………………………………… 8 A cos j=1
  • NTC range (AKO-14931)…………………………………. -50 ºC to 99.9 ºC
  • Range 4-20 mA…………. Configurable from -100 to 900 (1000 levels)
  • Resolution ………………………………………………………………………..0,1
  • Accuracy class (-40 ºC to 40 ºC):………………….. ±1 ºC acc/ EN 12830
  • Response time:……………………………………………………. < 20 seconds
  • Maximum relative time error:…………………………………………< 0.1 %
  • Marked according to UNE-EN 12830……………..S,A,1,-40 ºC + 40 ºC
  • ……………………………………………………… Digunakake ing panyimpenan (S)
  • ……………………………………………………….. Tipe Lingkungan Iklim (A)
  • …………………………………………………………………. Kelas akurasi (1)
  • Maximum input power……………………………………………………8.5 VA
  • Working ambient temperature…………………………………0 ºC to 40 ºC
  • Storage ambient temperature……………………………… -20 ºC to 60 ºC
  • Degree of protection…………………………………………………………IP40
  • Insulasi kaping pindho antarane sumber daya, sirkuit sekunder lan output relay.
  • Installation category……………………………………… II acc/ EN 61010-1
  • Pollution degree…………………………………………… II acc/ EN 61010-1
  • Maintenance of date and time without power supply……Up to 2 days
  • Internal buzzer………………………………………………….. 70dB at 30 cm
  • SD cards accepted……………………………………SD/SDHC (FAT / FAT32)

 Wiring

AKO-CAMRegis-Basic (8)

Operasi

Fungsi tombol

  • AKO-CAMRegis-Basic (9)key: A short press displays the maximum value reached in the last 24h, and the time when all the active inputs were reached. In the programming menu it allows scrolling around the different levels, or during the setting of a parameter, changing its value.
  • AKO-CAMRegis-Basic (9) key: A short press displays the minimum value reached in the last 24h, and the time when all the active inputs were reached. In the programming menu it allows scrolling around the different levels, or during the setting of a parameter, changing its value.
  • AKO-CAMRegis-Basic (9) key: A short press downloads the data of the ongoing log onto the SD card (if it has been inserted)
  • AKO-CAMRegis-Basic (2)key: A short press downloads ALL the logged data onto the SD card (if it has been inserted). The save without changes, return to previous level or exit programming parameter appears on the programming menu.
  • SET key: A short press downloads the data of the last log onto the SD card (if it has been inserted).
  • Silences weker akustik (miturut parameter P50).
  • Ing pemrograman, konfirmasi pilihan lan nyimpen nilai sing dilebokake.
  • AKO-CAMRegis-Basic (9)  AKO-CAMRegis-Basic (2) keys : Pressing for over 10 seconds accesses the data log display menu.
  • Pencet AKO-CAMRegis-Basic (9) kanggo milih blok log banjur pencet SET kanggo ngakses.
  • Pencet  AKO-CAMRegis-Basic (9) kanggo milih log sing bakal ditampilake, sawise 1 detik nilai saben input bakal ditampilake, nuduhake tanggal lan wektu log.
  • N + O keys : Pressing for over 10 seconds accesses the alarms log display menu.
    Press N / Q to select the input to be displayed and press SET.
    Press N / Q to select the event to be displayed (no. 1 is the most recent event), after 1 second the value of each input will be displayed, indicating the date and time of the event.
  • AKO-CAMRegis-Basic (9) keys: Pressing them for over 10 seconds accesses the programming menu.

AKO-CAMRegis-Basic (7)

AKO-CAMRegis-Basic (6)

Struktur data log

  • Data sing dicathet disimpen ing memori internal logger sing diatur ing blok log. Periode wektu sing disimpen ing saben blok, lan kapasitas maksimum memori internal, gumantung ing interval log (parameter L1), minangka ditampilake ing tabel.
  • Logger nduweni slot kanggo kertu SD, sing ngidini nransfer data sing disimpen kanggo ditampilake ing komputer utawa disimpen minangka serep. Data iki disimpen ing format spreadsheet (.csv), diatur kanthi cara ing ngisor iki:

PENTING: Do not remove the SD card until the indicator turns off. The download may take several minutes depending on the data saved.

AKO-CAMRegis-Basic (5)

AKO-CAMRegis-Basic (4)

  • Downloads ALL the logged data (P key)
    loro files kui jenenge taun, sasi lan dina download, ing rong folder beda ALL lan ALARMS. Pisanan ngandhut file karo kabeh data mlebu dening piranti nganti banjur lan kaloro ngemot file karo acara sing disimpen nganti saiki (pirsani bagean 5.2):
  •  Log weker
    This function saves an event whenever an alarm is activated or deactivated. To download the events log data, press the P key, all the data logged up to date are downloaded onto the SD card, including the events log, contained in the “ALARMS” folder.
  •  Wiwitan wiwitan
    Tanggal lan wektu bakal dijaluk nalika wiwitan wiwitan.

AKO-CAMRegis-Basic (3)

 Menu pemrograman (parameter)
To access the parameter programming menu, press the N + Q keys at the same time. Refer to the list of available parameters in section 5 of this manual. After 20 seconds without touching any key, the unit returns to the previous level. If it is in level 3 the changes will not be saved.

AKO-CAMRegis-Basic (2)

Parameter lan tabel pesen

Ing Def. kolom nuduhake paramèter gawan pabrik. Yen ora dituduhake, nilai suhu dituduhake ing ºC (suhu sing padha karo ºF).

Level 1 Menu lan katrangan
In P Konfigurasi Input Level 2
Deskripsi Level 3 Min. Def. Maks.
i1 Tipe input 1: 0: Disabled 1: NTC 2: 4-20 mA 3: Input digital (NO) 4: Input digital (NC) 0 1 4
i2 Nilai 4 mA input 1 -100 0 i3
i3 Nilai 20 mA input 1 i2 100 900
i4 Input kalibrasi 1 -20 0 20
i11 Tipe input 2: 0: Disabled 1: NTC 2: 4-20 mA 3: Input digital (NO) 4: Input digital (NC) 0 0 4
i12 Nilai 4 mA input 2 -100 0 i13
i13 Nilai 20 mA input 2 i12 100 900
i14 Input kalibrasi 2 -20 0 20
EP Metu menyang Level 1
AL Konfigurasi Weker Level 2
Deskripsi Level 3 Min. Def. Maks.
A0 Input weker 1: 0: Pateni; 1: Diaktifake 0 0 1
A1 Input nilai weker MAX 1 A2 99.9 999*
A2 MIN input nilai weker 1 -999* -50 A1
A3 Tundha input weker 1 0 0 120
A4 Input output weker 1: 0: Ora ana output 1: Mung akustik 2: Mung relay 3: Akustik + relay 0 0 3
A10 Input weker 2: 0: Pateni; 1: Diaktifake 0 0 1
A11 Input nilai weker MAX 2 A12 0 999*
A12 MIN input nilai weker 2 -999* 0 A11
A13 Tundha input weker 2 0 0 120
A14 Input output weker 1: 0: Ora ana output 1: Mung akustik 2: Mung relay 3: Akustik + relay 0 0 3
EP Metu menyang Level 1
Cn F Level 2 Konfigurasi Umum
Deskripsi Level 3 Min. Def. Maks.
P2 Fungsi kode akses: 0: Ora aktif; 1: Blok akses parameter 0 0 1
P3 Parameter standar: 0: Ora; 1: Nggih 0 0 1
P5 Alamat MODBUS kanggo unit karo komunikasi 1 1 255
P7 Temperature display mode: 0: Integers in ºC  1: One decimal point in ºC2: Integers in ºF  3: One decimal point in ºF 0 1 3
P8 Input sing bakal ditampilake: 0: Input Carrusel 1 - Input 2; 1: Input 1; 2: Input 2 0 1 2
P50 Bisu weker nganggo tombol SET: 0: Pateni 1: Mung swara 2: Mung relay 3: Swara lan relay 0 1 3
EP Metu menyang Level 1
d LG Konfigurasi Logger Level 2
Deskripsi Level 3 Min. Def. Maks.
L1 Log interval: 0:          1 minute           1: 5 minutes  2: 15 minutes3: 30 minutes  4: 60 minutes 0 2 4
L2 Mbusak rekaman lan log acara: 0: Ora; 1: Nggih 0 0 1
L3 Day of the start of the log: 0: Monday 1: Tuesday 2: Wednesday 3: Thursday4: Friday  5: Saturday 6: Sunday 0 0 6
L4 Pamisah desimal ing .csv files: 0:, 1: . 0 0 1
EP Metu menyang Level 1
r tC Level 2 Tanggal lan wektu
Deskripsi Level 3 Min. Def. Maks.
r1 jam 0 0 23
r2 menit 0 0 59
r3 Dina 1 1 31
r4 wulan 1 1 12
r5 taun 12 12 99
r6 Ganti jam otomatis: 0: Ora; 1: Nggih 0 1 1
EP Metu menyang Level 1
tid Level 2 Akses kontrol lan Informasi
Deskripsi Level 3 Min. Def. Maks.
L5 Sandi 0 99
PU Versi program
Pr Revisi program
EP Metu menyang Level 1

Dokumen / Sumber Daya

PDF thumbnailCAMRegis Basic
Owner's Manual · 351572422, 1572H422, 351572422.cdr, CAMRegis Basic

Referensi

Takon Pitakonan

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

Takon Pitakonan

Ask about setup, compatibility, troubleshooting, or anything missing from this manual. Name and email are optional.