UfiSpace-LOGO

UfiSpace S9510-30XC Disaggregated Cell Site Gateway Router

UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-PRODUCT

Swaraview

  • UfiSpace S9510-30XC minangka router kotak putih jaringan terbuka kanthi kinerja dhuwur lan serbaguna sing dirancang kanggo ngatasi kabutuhan transportasi backhaul sing ganti amarga telekomunikasi nggawe transisi saka teknologi warisan menyang 5G.
  • Iki ngidini panyedhiya telekomunikasi lan layanan nyebarake infrastruktur jaringan terbuka sing dipisahake kanggo ngedhunake biaya lan skala layanan sing wis ana kanthi cepet kanggo komputasi pinggiran, backhaul seluler, lan aplikasi akses broadband.
  • S9510-30XC dibuktekake ing mangsa ngarep kanthi prosesor 4-inti sing kuat, antarmuka kacepetan dhuwur 25GE/100GE, lan fitur wektu lengkap sing ndhukung IEEE 1588v2 lan SyncE, sing ngidini panyedhiya layanan gampang migrasi saka 2G, 3G, 4G BBU menyang 5G RAN. Cocog kanggo panyebaran ing njero ruangan lan ruangan kanthi komponen sing bisa diganti panas kanggo kepenak, kasedhiyan tambah, linuwih lan biaya pangopènan sing murah.
  • Dokumen iki nerangake proses instalasi hardware kanggo S9510-30XC.

Persiapan

Piranti Instalasi

UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-1

  • PC karo piranti lunak emulasi terminal. Deleng bagean "Persiyapan Sistem Awal" kanggo rincian.
  • Baud rate: 115200 bps
  • Bit data: 8
  • Paritas: Ora ana
  • Stop bit: 1
  • Kontrol aliran: Ora ana

Persyaratan Lingkungan Instalasi 

  • Cadangan Daya: Sumber daya S9510-30XC kasedhiya karo:
    • Versi DC: 1 + 1 aktif-aktif -36 nganti -75V DC unit sumber daya sing bisa diganti utawa;
    • Versi AC: 1+1 aktif-aktif universal 100 nganti 240V AC unit sing bisa diganti.
      Kanggo mesthekake yen desain daya feed aktif-aktif bisa digunakake kanthi bener, lapangan kanthi sirkuit daya dual dianjurake kanthi cadangan paling sethithik 400 watt ing saben sirkuit daya.
  • Space Clearance: S9510‐30XC jembaré 17.32 inci (44cm) lan dikirim nganggo rak gunung kurung cocok kanggo 19-inch (48.3cm) rak sudhut lan luwes soyo tambah ril kasedhiya kanggo ambane rak saka 22 inci (55.9cm) kanggo 33 inci (83.8cm). Ambane sasis S9510-30XC yaiku 11.89 inci (30.2cm) tanpa unit sing bisa diganti lapangan (FRU). Gagang kanggo unit kipas bakal ngluwihi 1 inci (2.5cm) lan gagang kanggo sumber daya bakal ngluwihi 1.06 inci (2.7cm). Kanggo nampung inlet udara lan kabel ngarep, reresik ruang minimal sing disaranake 6 inci (15.2cm) kanggo ngarep unit. Kanggo nampung gagang penggemar, disaranake reresik ruang minimal 1 inci (2.5cm) kanggo mburi unit. Total ambane cadangan minimal 18.89 inci (47.9cm) dibutuhake.UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-2
  • Pendinginan: Arah aliran udara S9510-30XC ngarep-mburi. Priksa manawa peralatan ing rak padha duwe arah aliran udara padha.UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-3

Preparation Check List 

UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-4

Isi Paket

Dhaptar Aksesoris

UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-5

Informasi Fisik Komponen 

UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-6

Ngenali Sistem Panjenengan

S9510-30XC Luwihview

UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-7

Versi DC PSU Swaraview

Unit sumber daya (PSU) kanthi redundansi 1 + 1. Hot swappable, field-replaceable unit (FRU).

UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-8

Versi AC PSU Overview

Unit sumber daya (PSU) kanthi redundansi 1 + 1. Hot-swappable, field-replaceable unit (FRU).

UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-9

Penggemar Overview

4 + 1 Redundant, hot-swappable, field-replaceable unit (FRU).

UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-10

Port liwatview 

UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-11 UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-12

Pemasangan Rak

UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-13Disaranake instalasi ditindakake dening rong profesional sing dilatih. Siji individu kudu nyekel peralatan ing posisi ing rak nalika liyane ngamanake ing panggonan.

  1. Amanake kurungan rak dipasang ing router.
    Nyelarasake krenjang gunung rak karo bolongan kasedhiya ing loro-lorone saka cilik lan aman krenjang nggunakake 8 M4.0 * L6.5mm ngawut-awut kasedhiya karo paket.UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-14
  2. Ngamanake router menyang kiriman rak.
    Tandhani lokasi ing loro kiriman kanggo mesthekake leveled sadurunge ngamanake router
    rak. (Waca Gambar 11). Kanggo rak 4 kirim, pisanan ngamanake alur soyo tambah luwes kanggo mburi dalan nggunakake ngawut-awut M4.0 * L6.5mm kasedhiya ing paket. Banjur aman rel soyo tambah luwes kanggo kiriman rak. (Waca Gambar 12).

UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-15Ilustrasi mung kanggo tujuan referensi. Skenario nyata bisa beda-beda. Ngawut-awut kanggo kiriman rak ora klebu.

UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-16

Nginstal Fan Modul

Modul penggemar minangka unit sing bisa diganti panas (FRU), sing bisa diganti nalika router beroperasi anggere kabeh modul sing isih ana dipasang lan digunakake. Penggemar wis diinstal lan langkah-langkah ing ngisor iki minangka pandhuan babagan carane nginstal modul penggemar anyar.

  1. Loosen meneng tawanan dumunung ing modul penggemar.UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-17
  2. Genggeman gagang kipas lan tarik metu saka teluk penggemar.UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-18
  3. Selarasake modul penggemar anyar karo teluk penggemar.
  4. Kasebut kanthi teliti, geser modul penggemar anyar menyang teluk penggemar lan alon-alon push nganti siram karo kasus.
  5. Ngamanake sekrup tawanan ing modul penggemar kanggo ngunci penggemar ing panggonan.UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-19

Nginstal Unit Power Supply

Unit catu daya (PSU) minangka unit sing bisa diganti medan panas (FRU) lan bisa diganti nalika router beroperasi anggere PSU sing isih ana (kapindho) dipasang lan digunakake. PSU wis diinstal lan ing ngisor iki minangka pandhuan babagan carane nginstal PSU anyar.

UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-20

UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-13Bahaya kejut!
Kanggo safety, copot kabeh input daya saka unit sumber daya sadurunge nglayani router.

  1. Goleki tab release ing PSU. Banjur pencet terus tab release kanggo mbukak kunci PSU saka teluk daya.
  2. Nalika nahan tab release, genggeman gagang PSU lan tarik metu saka teluk daya.UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-21
  3. Selarasake PSU anyar karo teluk daya, mesthekake konektor daya PSU ing posisi sing bener.
  4. Kasebut kanthi teliti, geser PSU anyar menyang teluk daya lan alon-alon push nganti flush karo kasus.
  5. Klik swara bakal keprungu nalika PSU diinstal kanthi bener. PSU ora bakal mlaku kabeh yen ana ing arah sing salah.

UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-15Ilustrasi mung kanggo tujuan referensi. Skenario nyata bisa beda-beda.

UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-22

Grounding Router

Disaranake owah-owahan peralatan rampung ing sistem rak grounded. Iki bakal nyuda utawa nyegah risiko bebaya kejut, karusakan peralatan, lan potensial korupsi data.
Router bisa didhasarake saka kasus router lan unit sumber daya (PSU). Nalika grounding PSUs, mesthekake yen loro PSUs grounded ing wektu sing padha yen salah siji saka iku dibusak. A lug grounding, ngawut-awut M4, lan washers kasedhiya karo isi paket, Nanging, kabel grounding ora klebu. Kanggo penak, ana rong lokasi ing kasus sing bisa dipasang lug grounding.

Pandhuan ing ngisor iki kanggo grounding router.

UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-23Peralatan iki kudu lemah. Aja ngalahake konduktor lemah utawa ngoperasikake peralatan tanpa grounding peralatan kanthi bener. Yen ana kahanan sing durung mesthi babagan integritas grounding peralatan, hubungi otoritas inspeksi listrik utawa tukang listrik sing wis disertifikasi.

  1. Sadurunge grounding router, priksa manawa rak wis grounded bener lan tundhuk karo pedoman peraturan lokal. Priksa manawa ora ana sing bisa ngalangi sambungan kanggo grounding lan mbusak cat utawa bahan sing bisa nyegah kontak grounding sing apik.
  2. Copot insulasi saka kabel grounding AWG ukuran #6 (ora kasedhiya ing isi paket), ninggalake 0.5” +/‐0.02” (12.7mm +/‐0.5mm) kabel grounding sing katon.
  3. Lebokake kabel grounding sing kapapar kabeh menyang bolongan grounding lug (disedhiyakake karo isi paket).
  4. Nggunakake alat crimping, aman kabel grounding menyang lug grounding.UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-24
  5. Temokake lokasi sing ditemtokake kanggo ngamanake lug grounding, sing ana ing sisih pinggir dalan.
  6. Nggunakake 2 sekrup M4 lan 4 mesin cuci (kasedhiya karo isi paket), kunci lug grounding kanthi kuat menyang salah siji lokasi grounding sing wis ditemtokake ing router.UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-25

Daya Nyambung

Versi DC

  1. Priksa manawa ana cukup daya kanggo nyuplai sistem.
    Konsumsi daya sistem maksimum yaiku 268 watt. Disaranake kanggo mesthekake yen daya cukup wis dilindhungi undhang-undhang saka sistem distribusi daya sadurunge instalasi. Uga, priksa manawa PSU loro-lorone wis diinstal kanthi bener sadurunge nylametake peralatan kasebut, amarga S9510‐30XC dirancang kanggo ndhukung redundansi daya 1 + 1.
  2. Pasang kabel daya.
    Temokake blok terminal jinis skru daya DC ing PSU DC. Pasang kabel daya UL 1015, 14 AWG DC (ora kasedhiya ing isi paket) menyang konektor inlet DC ing PSU.

UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-47Vol mbebayanitage! 

  • Kudu dipateni sadurunge dicopot!
  • Priksa manawa kabeh sambungan listrik wis grounded sadurunge urip
  • Sumber daya DC kudu diubengi kanthi andal

UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-26

Kencengake sekrup menyang torsi sing ditemtokake.
Kencengake sekrup nganti nilai torsi 7.0+/‐0.5kgf.cm. Yen torsi ora cukup, lug ora bakal aman lan bisa nyebabake malfungsi. Yen torsi kakehan, blok terminal utawa lug bisa rusak.

UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-27

Feed daya DC menyang sistem.
PSU bakal langsung ngasilake 12V lan 5VSB menyang sistem nalika sumber daya ‐36V nganti ‐75V DC ditrapake. PSU wis dibangun ing 20 amperes, sekring tumindak cepet adhedhasar kapasitas maksimum PSU, kang bakal tumindak minangka pangayoman sistem undakan kapindho ing kasus sekring unit distribusi daya kang ora dienggo.
Priksa manawa catu daya digunakake.
Yen disambungake kanthi bener, nalika diuripake, LED ing PSU bakal madhangi warna Ijo sing nuduhake operasi normal.

Versi AC 

  1. Priksa manawa ana cukup daya kanggo nyuplai sistem.
    Konsumsi daya sistem maksimum yaiku 263 watt kanthi vol inputtage saka 100-240V AC. Disaranake kanggo mesthekake yen daya cukup wis dilindhungi undhang-undhang saka sistem distribusi daya sadurunge instalasi. Uga, priksa manawa PSU loro-lorone wis diinstal kanthi bener sadurunge nylametake peralatan kasebut, amarga S9510‐30XC dirancang kanggo ndhukung redundansi daya 1 + 1.
  2. Pasang kabel daya.
    Tancepake kabel listrik menyang PSU AC lan kenceng.
  3. Priksa manawa catu daya digunakake.
    Yen disambungake kanthi bener, nalika diuripake, LED ing PSU bakal madhangi warna Ijo sing nuduhake operasi normal.

UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-28

Verifikasi Sistem Operasi

LED Panel ngarep

Verifikasi operasi dhasar kanthi mriksa LED sistem sing ana ing panel ngarep. Nalika operasi normal, LED PWR, FAN, lan STAT kabeh kudu katon ijo.

UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-29 UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-30

UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-31

PSU FRU LED Kab 

UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-32

Kipas FRU LED 

UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-33

Manajemen port LED 

UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-34

Persiyapan Sistem Awal

Nggawe sambungan serial pisanan.
Kanggo nemtokake alamat IP, sampeyan kudu duwe akses menyang antarmuka baris perintah (CLI). CLI minangka antarmuka adhedhasar teks sing bisa diakses liwat sambungan serial langsung menyang piranti.
Akses CLI kanthi nyambungake menyang port console. Sawise sampeyan nemtokake alamat IP, sampeyan bisa ngakses sistem liwat Telnet utawa SSH dening Putty, TeraTerm utawa HyperTerminal.
Tindakake langkah ing ngisor iki kanggo ngakses piranti liwat sambungan serial:

  1. Sambungake kabel konsol.
    • Konsol bisa disambungake nggunakake port RJ45 kanthi label IOIO.
    • Kanggo nyambung menyang console, pasang kabel serial RJ45 menyang port console lan sambungake ujung liyane menyang komputer. Jinis kabel bisa beda-beda gumantung saka model.UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-35
  2. Priksa kasedhiyan kontrol serial.
    Pateni program komunikasi serial sing mlaku ing komputer kayata program sinkronisasi kanggo nyegah gangguan.
  3. Bukak emulator terminal.
    Bukak aplikasi emulator terminal kayata HyperTerminal (Windows PC), Putty utawa TeraTerm lan atur aplikasi kasebut. Setelan ing ngisor iki kanggo lingkungan Windows (sistem operasi liyane beda-beda):
    • Baud rate: 115200 bps
    • Bit data: 8
    • Paritas: Ora ana
    • Stop bit: 1
    • Kontrol aliran: Ora ana
  4. Mlebet menyang piranti.
    Sawise sambungan digawe, pituduh kanggo jeneng pangguna lan sandhi ditampilake. Ketik jeneng pangguna lan sandhi kanggo ngakses CLI. Jeneng pangguna lan sandhi kudu diwenehake dening vendor Sistem Operasi Jaringan (NOS).

Sambungan Kabel

Nyambungake Kabel USB Extender
Sambungake plug USB 3.0 A Type (konektor lanang) menyang port USB (konektor wadon) sing ana ing panel ngarep router. Port USB minangka port pangopènan.

UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-36

Nyambungake Kabel menyang Antarmuka ToD 

UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-15Dawane maksimum kabel Ethernet straight-through ngirim ora luwih saka 3 meter.

  1. Sambungake salah siji ujung kabel Ethernet straight-through menyang unit GNSS
  2. Sambungake ujung liyane kabel Ethernet straight-through menyang port sing ditandhani "TOD" sing ana ing panel ngarep router.

UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-37

Nyambungake Kabel menyang Antarmuka BITS 

UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-15Dawane maksimum kabel BITS ora luwih saka 3 meter.

  1. Sambungake siji ujung kabel RJ48 sing dilindhungi menyang port kanthi label "BITS" sing ana ing panel ngarep router.
  2. Sambungake ujung kabel liyane menyang patch BITS utawa panel demarkasi.UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-38
  3. Ing ngisor iki pinout kanggo port BITS.UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-39

Nyambungake Antarmuka GNSS
Sambungake antena GNSS eksternal kanthi impedansi 50 ohm menyang port sing ditandhani "GNSS ANT" sing ana ing panel ngarep router.

UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-40

Nyambungake Antarmuka 1PPS 

UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-15Dawane maksimum kabel 1PPS coaxial SMB/1PPS Ethernet ngirim ora luwih saka 3 meter.

Sambungake kabel 1PPS eksternal kanthi impedansi 50 ohm menyang port kanthi label "1PPS".

UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-41

Nyambungake Antarmuka 10MHz 

UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-15Dawane maksimum kabel SMB coaxial 10MHz ora luwih saka 3 meter.

Sambungake kabel 10MHz eksternal kanthi impedansi 50 ohm menyang port kanthi label "10MHz".

UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-42

Nyambungake Transceiver 

UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-15Kanggo nyegah over-tightening lan ngrusak serat optik, ora dianjurake kanggo nggunakake dasi wraps karo kabel optik.

Waca pandhuan ing ngisor iki sadurunge nyambungake transceiver: 

  • Sadurunge nginstal router, nimbang syarat papan rak kanggo manajemen kabel lan rencana sing cocog.
  • Disaranake nggunakake tali gaya pancing-lan-loop kanggo ngamanake lan ngatur kabel.
  • Kanggo manajemen sing luwih gampang, label saben kabel serat optik lan rekam sambungane.
  • Njaga garis sing jelas saka tampilan LED port kanthi nuntun kabel adoh saka LED.

UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-13Sadurunge nyambungake apa wae (kabel, transceiver, lsp.) menyang router, priksa manawa sampeyan ngeculake listrik statis sing bisa kedadeyan sajrone nangani. Disaranake uga supaya kabel ditindakake dening profesional sing wis grounded, kayata nganggo tali bangkekan ESD.

Mangga tindakake langkah ing ngisor iki kanggo nyambungake transceiver. 

  1. Copot transceiver anyar saka kemasan protèktif.
  2. Copot plug protèktif saka port transceiver.
  3. Selehake bail (nangani kabel) ing posisi sing ora dikunci lan selarasake transceiver karo port.
  4. Geser transceiver menyang port lan gunakake tekanan sing lembut kanggo ngamanake ing panggonane. Klik swara bisa dirungokake nalika transceiver diamanake ing port.

Nginstal Antena  

UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-15Priksa manawa kekuatan sinyal satelit luwih saka 30db, nalika nggunakake simulator GNSS kanggo testing.

Waca pandhuan ing ngisor iki sadurunge nginstal antena.

  • S9510‐30XC ndhukung macem-macem jinis jinis frekuensi panrima, kalebu GPS L1C/A, GLONASS L1OF, BeiDou B1, lan Galileo E1B/C.
  • Sensitivitas minimal frekuensi panrima (RF) yaiku -166dBm.
  • S9510-30XC ndhukung antena GNSS pasif lan aktif, lan kanthi otomatis ndeteksi jinis antena sing dipasang.
  • Yen kekuatan sinyal sing ditampa luwih murah tinimbang 30db, panrima GNSS bakal gagal ngasilake perkiraan lokasi sing akurat.

Kanggo ngoptimalake kinerja antena, dianjurake kanggo milih gendheng utawa lantai ndhuwur sing bebas saka sumbatan utawa alangan sinyal.
Waca pandhuan ing ngisor iki sadurunge nginstal antena aktif:

  • Nalika antena aktif dipasang, S9510-30XC bisa nyedhiyakake nganti 5V DC/150mA ing port GNSS.
  • Yen ana GNSS amplifier, splitter DC-diblokir utawa cascaded dipasang, fungsi deteksi GNSS bisa kena pengaruh, nyebabake kesalahan jam satelit GNSS.
  • Disaranake sampeyan nggunakake antena aktif dilengkapi 50 ohm impedansi cocog, 5V DC sumber daya saged, max. NF 1.5dB lan 35~42dB internal LNA gain kanggo njaluk kekuatan sinyal cukup kuwat ing macem-macem kahanan cuaca.
  • Kanggo nyegah karusakan sing disebabake dening lonjakan daya utawa serangan kilat, priksa manawa ana proteksi lonjakan dipasang ing antena GNSS.

UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-43

Ati-ati lan Pernyataan Kepatuhan Peraturan

UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-44Kabar Safety
Ati-ati! Bahaya kejut!
Kanggo mateni daya, copot kabeh kabel daya saka unit.

UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-45Bahaya Listrik: Mung personel sing mumpuni sing kudu nindakake prosedur instalasi.

Pènget: Penyetor daya Ngalih Jaringan ora duwe switch kanggo nguripake lan mateni unit. Sadurunge servis, copot kabeh kabel daya kanggo nyopot daya saka piranti. Priksa manawa sambungan kasebut gampang diakses.

UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-46Ati-ati: Sadurunge masang piranti, priksa manawa rak bisa ndhukung tanpa ngrusak stabilitas. Yen ora, ciloko pribadi lan/utawa karusakan peralatan bisa nyebabake.

UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-46Ati-ati: Panganggone kontrol utawa pangaturan utawa kinerja prosedur liyane saka sing kasebut ing kene bisa nyebabake paparan radiasi sing mbebayani.

UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-46Ati-ati: Mung transceiver optik Laser Kelas 1 sing kudu digunakake.

UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-46Pènget: Aja nggunakake piranti optik kanggo view output laser. Panganggone instrumen optik kanggo view output laser mundhak bebaya mripat. Gunakake mung UL/CSA, IEC/EN60825-1/‐2 modul pluggable dikenali.

UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-46Pènget:
Peralatan kasebut mung kudu digunakake ing area akses sing diwatesi.
Peralatan kasebut mung kudu dioperasikake dening wong sing trampil utawa dilatih.
Peralatan lan modul kasebut mung kudu didandani, dijaga utawa diganti dening personel sing trampil.
Wong sing dilatih yaiku istilah sing ditrapake kanggo wong sing wis dilatih lan dilatih dening wong sing trampil, utawa sing diawasi dening wong sing trampil.

Wara-wara Kelas A ITE 

UfiSpace-S9510-30XC-Disaggregated-Cell-Site-Gateway-Router-FIG-47Peralatan iki tundhuk karo Kelas A CISPR 32. Ing lingkungan omah, peralatan iki bisa nyebabake gangguan radio.

Kabar VCCI 

Iki minangka peralatan Kelas A. Operasi peralatan iki ing lingkungan omah bisa nyebabake gangguan radio. Ing kasus kaya mengkono, pangguna bisa uga kudu njupuk tindakan koreksi.

Perhatian lan pratelan kepatuhan peraturan kanggo NEBS: 

  • "Piranti Perlindhungan Surge eksternal (SPD) kudu digunakake karo peralatan sing nganggo daya AC lan Piranti Proteksi Surge kudu dipasang ing lawang layanan daya AC."
  • Desain peralatan kasebut yaiku terminal RTN kudu diisolasi saka sasis utawa rak. (Terminal input DC yaiku DC-I (Isolated DC return))
  • PÈNGET: Port intra-bangunan OOB (Ethernet) saka peralatan utawa subassembly cocog kanggo sambungan menyang kabel utawa kabel utawa kabel intra-bangunan utawa ora katon. Port intrabuilding saka peralatan utawa subassembly ORA disambungake kanthi metal menyang antarmuka sing nyambung menyang OSP utawa kabel luwih saka 6 meter.
    (kira-kira 20 kaki). Antarmuka iki dirancang kanggo digunakake minangka antarmuka intra-bangunan mung (Port Tipe 2, 4, utawa 4a kaya sing diterangake ing GR-1089) lan mbutuhake pamisahan saka kabel OSP sing kapapar. Penambahan Pelindung Utama ora proteksi sing cukup kanggo nyambungake antarmuka kasebut kanthi metalik menyang sistem kabel OSP.

KONTAK

www.ufispace.com

 

Dokumen / Sumber Daya

UfiSpace S9510-30XC Disaggregated Cell Site Gateway Router [pdf] Pandhuan Instalasi
S9510-30XC Disaggregated Cell Site Gateway Router, S9510-30XC, Disaggregated Cell Site Gateway Router, Cell Site Gateway Router, Site Gateway Router, Gateway Router

Referensi

Ninggalake komentar

Alamat email sampeyan ora bakal diterbitake. Kolom sing dibutuhake ditandhani *