Ledvion LVT10004_3m6s_2700K

Ledvion 3M Single-Phase LED Track Lighting System with 6 Adjustable GU10 Spots, 2700K White

Merk: Ledvion | Model: LVT10004_3m6s_2700K

1. Produk Liwatview

The Ledvion single-phase LED track lighting system offers a modern and flexible solution for illuminating your space. Featuring a 3-meter track and six adjustable GU10 spots, this 2700K white system allows for targeted and customizable lighting, creating the perfect ambiance.

This system is designed for direct ceiling installation and is suitable for various indoor environments such as kitchens, living rooms, or any area requiring directional lighting. Its robust and modern design, with an elegant white finish and adjustable spots, provides both aesthetic appeal and functional versatility.

Ledvion 3M Single-Phase LED Track Lighting System installed in a modern living room, illuminating the space with warm light.

Figure 1: Ledvion track lighting system in a living room setting.

2. Apa ing Box

Priksa manawa kabeh komponen ana lan ora rusak sadurunge nerusake instalasi.

Contents of the Ledvion track lighting system box, including six spot lights, three track sections, GU10 bulbs, anti-glare grids, mounting hardware, and various connectors.

Figure 2: All components included in the Ledvion track lighting package (SKU: LVT10004_3m6s_2700K).

  • Ledvion Single-Phase LED Track Lighting System (3m track)
  • 6 x GU10 Orientable Spots
  • 6 x GU10 LED Bulbs (2700K)
  • Anti-Glare Grids (optional, included)
  • Piranti Pemasangan (sekrup, colokan tembok)
  • Track Connectors (L-connectors, straight connectors)
  • Power Feeder

3. Informasi Safety

Mangga maca kabeh instruksi safety kasebut kanthi teliti, sadurunge instalasi lan nggunakake. Gagal ngetutake instruksi kasebut bisa nyebabake kejut listrik, geni, utawa bebaya liyane.

  • Keamanan Listrik: Installation should only be performed by a qualified electrician or competent person. Ensure the main power supply is switched off at the circuit breaker before beginning any electrical work.
  • Voltage: This product operates on 230 Volts. Verify your electrical system's compatibility.
  • Mung nggunakake njero ruangan: This lighting system is designed for indoor use in dry locations. Do not expose to moisture or extreme temperatures.
  • Pemasangan: Priksa manawa permukaan sing dipasang kanthi struktural lan bisa ndhukung bobot piranti kasebut.
  • Tipe Bohlam: Gunakake mung bohlam LED GU10 kaya sing wis ditemtokake. Aja ngluwihi daya maksimal.tage.
  • panas: LED bulbs can generate heat. Allow sufficient ventilation around the fixture. Do not cover the spots with flammable materials.
  • Reresik: Pedhot daya sadurunge ngresiki. Gunakake kain alus lan garing. Aja nggunakake pembersih utawa pelarut sing abrasif.

4. Persiyapan & Instalasi

This section provides general guidance for installing your Ledvion track lighting system. Professional installation is recommended.

4.1 Nyiyapake Instalasi

  1. Pateni Daya: Locate your circuit breaker and turn off the power to the area where you will be installing the track light.
  2. Mbukak komponen: Copot kabeh barang saka kemasan kanthi ati-ati lan priksa apa ana kerusakan.
  3. Tata letak rencana: Determine the desired layout of your track system on the ceiling. Mark the mounting points for the track sections.

4.2 Mounting the Track

  1. Secure Track Sections: Using the provided mounting hardware, attach the track sections to the ceiling at your marked points. Ensure the track is securely fastened and level.
  2. Bagean Trek Sambungake: If using multiple track sections, use the provided connectors (e.g., straight connectors, L-connectors) to join them.
  3. Diagram showing various optional track connectors and accessories like power feeders, X-connectors, T-connectors, and pendant spot adjustable cords.

    Figure 3: Optional track connectors and accessories for system expansion.

  4. Install Power Feeder: Connect the power feeder to the track system at the designated entry point. This component will connect to your household electrical wiring.

4.3 Wiring (Disaranake Instalasi Profesional)

Connect the household electrical wiring to the power feeder according to local electrical codes. Ensure all connections are secure and insulated.

4.4 Installing the Spots

  1. Insert Spots: The spots feature a plug-and-play locking system. Align the spot's connector with the track's groove and insert it.
  2. Secure Spots: Rotate the spot's locking mechanism to secure it firmly in place on the track.
  3. Four-panel diagram illustrating the plug-and-play installation process for the track lighting spots, showing how to insert and lock them onto the track.

    Figure 4: Plug-and-play installation of the track spots.

  4. Pasang bohlam GU10: Insert the GU10 LED bulbs into each spot.
  5. Optional Anti-Glare Grid: If desired, install the anti-glare grids into the spots. These are easy to add and remove.
  6. Diagram showing how to install the optional anti-glare grid into a track lighting spot, with the grid preventing direct light exposure.

    Figure 5: Installation of the optional anti-glare grid.

Once all components are installed, restore power to the circuit.

5. Operasi

The Ledvion track lighting system is designed for straightforward operation.

  • Daya On/Off: Control the lighting system using your standard wall switch connected to the circuit.
  • Adjusting Spots: Each spot is adjustable and rotatable. You can tilt the spotlight 350 degrees in all directions to direct light precisely where needed.
  • Diagram illustrating the 350-degree adjustability and rotation of the track lighting spots, showing various angles of tilt and rotation.

    Figure 6: Adjustability and rotation of the track spots.

  • Repositioning Spots: To reposition a spot along the track, ensure the power is off, then unlock the spot's mechanism, slide it to the desired location, and re-lock it.

6. Pangopènan

Regular maintenance ensures the longevity and optimal performance of your lighting system.

  • Reresik: Disconnect power before cleaning. Wipe the track and spots with a soft, dry, lint-free cloth. Do not use harsh chemicals, abrasive cleaners, or sprays directly on the fixture.
  • Penggantian bohlam: Ensure power is off and the bulb has cooled before attempting to replace a GU10 LED bulb. Gently twist and pull to remove the old bulb, then insert and twist the new bulb into place.
  • Pemriksaan: Periodically check all connections and mounting points for tightness and security.

7. Ngatasi masalah

If you encounter issues with your Ledvion track lighting system, refer to the following common problems and solutions:

MasalahKemungkinan PenyebabSolusi
Cahya ora urip.Ora ana daya kanggo sirkuit.
Sambungan kabel sing longgar.
Bohlam sing rusak.
Priksa pemutus sirkuit.
Priksa kabeh sambungan kabel (priksa manawa daya wis mati).
Ganti bohlam nganggo bohlam sing wis dingerteni bisa digunakake.
One or more spots not lighting up.Bulb not properly seated or faulty.
Spot not properly connected to the track.
Ensure bulb is fully inserted and twisted. Replace bulb.
Check if the spot is securely locked onto the track.
Lampu kelip-kelip.Sambungan longgar.
Ngalih dimmer sing ora kompatibel (yen ana).
Bohlam sing rusak.
Priksa kabeh sambungan.
Priksa manawa saklar dimmer kompatibel karo lampu LED.
Ganti bohlam.

Yen masalah isih ana sawise nyoba solusi kasebut, hubungi dhukungan pelanggan Ledvion.

8. Spesifikasi Produk

MerkLedvion
Nomer ModelLVT10004_3m6s_2700K
Ukuran produk (L x W x H)105 x 20 x 20 cm
Bobot Barang3.47 kg
Jumlah Item1
GayaTrack Lighting Set 4
warnaPutih (2700K)
Voltage230 volt
Tipe PlugElectrical (Wired)
Tipe BohlamLED (GU10)
Wattage3 Watts per spot
Suhu Warna2700 Kelvin (Warm White)
Label EnergiD (EPREL Link)
Negara AsalCina
Diagram showing the dimensions of the Ledvion track lighting spots: 175mm total height, 140mm visible height, and 52mm diameter.

Figure 7: Dimensions of the individual track spots.

Energy label for Ledvion LVB10002_1, showing energy efficiency class D and energy consumption of 3 kWh/1000h.

Figure 8: Energy Label for the product.

9. Warranty lan Dhukungan

For warranty information, technical support, or to inquire about spare parts, please refer to the official Ledvion website or contact their customer service directly. Details regarding specific warranty periods and support channels are typically provided with your purchase documentation or on the manufacturer's official resources.

Produsen: Ledvion

Kontak: Mangga ngunjungi www.ledvion.com kanggo informasi dhukungan.