This manual provides detailed instructions for the safe and efficient operation, maintenance, and troubleshooting of your HNZXIB Closed Loop Extractor SS-90G. This 1.5-inch double-layer stainless steel vacuum chamber/tube with a 90-gram capacity and tripod is designed for plant material extraction. Please read this manual thoroughly before use to ensure proper function and longevity of the equipment.

Produk Overview

The HNZXIB Closed Loop Extractor SS-90G is a robust system constructed from 304 food-grade stainless steel, ensuring durability and preventing contamination of raw materials. Key features include:

  • Kapasitas sing cukup: 90g capacity (volume after compressing the material) double-layer stainless steel tube. Hot and cold reactants can be added to the outer layer.
  • Upgraded Configuration: Features a food-grade stainless steel ball valve for enhanced robustness and pressure resistance. An additional vacuum gauge allows for convenient observation of reaction vacuum levels. The upgraded detachable tripod bracket offers flexible fixing methods.
  • Aksesoris Tambahan: Includes 2x 150 micron filters, 3x gaskets, 1x sealing tape, and 1x silicone pad.
  • Bahan: Made from 304 food-grade stainless steel, easy to clean and maintain.
HNZXIB Closed Loop Extractor SS-90G with components laid out

Image: HNZXIB Closed Loop Extractor SS-90G components displayed. This image shows the main extractor tube, valves, pressure gauge, clamps, and tripod legs, along with gaskets, filters, sealing tape, and a silicone pad.

Pandhuan Setup

Follow these steps to assemble your HNZXIB Closed Loop Extractor SS-90G. Ensure all components are clean and free from debris before assembly.

  1. Siapke komponen: Lay out all parts, including the main tube, valves, pressure gauge, clamps, tripod legs, gaskets, and sealing tape.
  2. Assemble Valves and Gauge: Attach the ball valves and vacuum gauge to their respective tri-clamp fittings. Ensure gaskets are properly seated for a tight seal.
  3. Attach Tripod Legs: Securely attach the three tripod legs to the bottom tri-clamp fitting using the provided clamps and tools. Ensure the legs are evenly spaced for stability.
  4. Connect Top Assembly: Place a gasket on the top flange of the main tube. Carefully align and attach the top assembly (with valve and pressure gauge) to the main tube using a tri-clamp. Ngencengi clamp kanthi aman.
  5. Connect Bottom Assembly: Place a gasket on the bottom flange of the main tube. Carefully align and attach the bottom assembly (with valve and tripod legs) to the main tube using a tri-clamp. Ngencengi clamp kanthi aman.
  6. Priksa pungkasan: Verify all connections are tight and secure. Ensure the tripod provides a stable base for the extractor.

Video: Closed Loop Extractor Installation Guide (Duration: 5:35). This video demonstrates the step-by-step assembly process for the HNZXIB Closed Loop Extractor, including attaching valves, the pressure gauge, and the tripod legs to the main chamber.

HNZXIB Closed Loop Extractor SS-90G parts display

Gambar: Detil view of HNZXIB Closed Loop Extractor SS-90G components, including the main tube, valves, pressure gauge, clamps, and tripod legs, along with gaskets, filters, sealing tape, and a silicone pad.

Instruksi Operasi

Operating a closed-loop extractor requires careful attention to safety and procedure. This section provides general guidance. Always refer to specific solvent handling guidelines and local regulations.

  1. Bahan Beban: Ensure the material to be extracted is properly prepared and loaded into the extraction column.
  2. Connect Solvent Tank: Connect the solvent tank to the appropriate inlet on the extractor.
  3. Vacuum and Pressure Check: Use the vacuum gauge to ensure the system is sealed and can hold a vacuum. This is crucial for safe operation.
  4. Solvent Introduction: Slowly introduce the solvent into the extraction column. Monitor pressure and flow.
  5. Extraction Process: Allow sufficient time for the solvent to interact with the material.
  6. Koleksi: Open the appropriate valves to collect the extracted solution into a recovery tank.
  7. Solvent Recovery: Initiate the solvent recovery process, typically involving heating the collection vessel and condensing the solvent back into the solvent tank.
  8. Product Retrieval: Once solvent recovery is complete, safely open the system to retrieve the extracted product.

Cathetan Keamanan Penting: Operating closed-loop extraction systems involves handling flammable and pressurized materials. Always operate in a well-ventilated area, wear appropriate personal protective equipment (PPE), and ensure all connections are leak-free. Consult with experienced professionals and adhere to all safety protocols and local regulations.

Assembled HNZXIB Closed Loop Extractor SS-90G

Image: Fully assembled HNZXIB Closed Loop Extractor SS-90G, ready for operation.

Pangopènan

Regular maintenance ensures the longevity and safe operation of your HNZXIB Closed Loop Extractor SS-90G.

  • Reresik: After each use, thoroughly clean all components with appropriate cleaning agents to remove any residual material or solvent. Ensure all parts are dry before reassembly or storage.
  • Inspeksi Gasket: Regularly inspect all gaskets for signs of wear, cracking, or damage. Replace worn gaskets immediately to maintain a proper seal and prevent leaks.
  • Priksa katup: Periodically check the ball valves for smooth operation and ensure they open and close completely.
  • Kalibrasi Pengukur Tekanan: If accuracy is critical, consider periodic calibration of the vacuum gauge.
  • Panyimpenan: Store the extractor in a clean, dry environment when not in use.

Ngatasi masalah

This section addresses common issues you might encounter with your closed-loop extractor.

MasalahKemungkinan PenyebabSolusi
Loss of Vacuum/Pressure
  • Damaged or improperly seated gaskets.
  • Longgar clamps.
  • Katup rusak.
  • Inspect and replace all gaskets.
  • Tighten all tri-clamps aman.
  • Check valve operation; replace if necessary.
Slow Extraction Rate
  • Filter macet.
  • Insufficient solvent flow.
  • Material packed too tightly.
  • Ganti utawa ngresiki saringan.
  • Ensure solvent tank has adequate pressure/flow.
  • Repack material less densely.
Product Contamination
  • Improper cleaning.
  • Komponen sing rusak.
  • Non-food grade materials used.
  • Thoroughly clean all parts before use.
  • Inspect for damage; replace components as needed.
  • Ensure only specified food-grade materials are used.

If you encounter issues not listed here or require further assistance, please contact HNZXIB customer support.

Spesifikasi

FiturRincian
Dimensi produk13.4 x 15.7 x 26.8 inci
Bobot Barang9.72 kab
ProdusenHNZXIB
ASINB09FSVBTYS
Nomer Model ItemHNZXIB003
Tanggal Kapisan Kasedhiya21 Oktober 2021
Kapasitas90g (after compressing material)
Bahan304 Food Grade Stainless Steel
HNZXIB Closed Loop Extractor SS-90G dimensions

Image: HNZXIB Closed Loop Extractor SS-90G with key dimensions labeled.

Warranty lan Dhukungan

The HNZXIB Closed Loop Extractor SS-90G comes with a garansi 1 taun. This warranty covers manufacturing defects and malfunctions under normal use conditions. Please note that gaskets, filters, and other consumable accessories are excluded from this warranty.

For any product issues or support inquiries, please contact HNZXIB customer service. We are committed to resolving any problems you may encounter.

Manufacturer: HNZXIB

Seller: Henan Zhuoxian Import & Export Trading Co., Ltd.

© 2026 HNZXIB. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.