1. Pambuka
The APC Back-UPS BX1400UI is an Uninterruptible Power Supply (UPS) designed to protect your electronic equipment from power outages, surges, and spikes. Featuring Line Interactive Technology and Automatic Voltage Regulation (AVR), this unit provides reliable battery backup and surge protection for connected devices. It includes six IEC 320 C13 outlets, a USB interface for communication, and data line protection.

Gambar 1: Ngarep view of the APC Back-UPS BX1400UI.
2. Informasi Safety Penting
- Bahaya Listrik: Unit iki ngandhut voltase dhuwurtage components. Do not attempt to open the UPS casing, especially when connected to power. Refer all servicing to qualified personnel.
- Sambungan langsung: Always connect the UPS directly to a wall outlet. Do not use surge protectors, extension cords, or power strips with the UPS input.
- Ventilasi: Priksa manawa ventilasi ing sekitar UPS cukup. Aja nutupi bolongan ventilasi.
- Bau wiwitan: A new unit may emit a distinct odor, often described as similar to burnt plastic. This is normal and typically dissipates after a few weeks of continuous operation in a well-ventilated area. It is not indicative of a malfunction.
- Panggantos baterei: User-performed battery replacement during the warranty period will void the product warranty. Refer to the Maintenance section for details.
3. Isi Paket
Priksa manawa paket sampeyan ngemot item ing ngisor iki:
- APC Back-UPS BX1400UI Unit
- Two (2) IEC-C13 to IEC-C14 power cables (for connecting devices to the UPS)
- Manual pangguna (dokumen iki)
Cathetan: The input power cable (for connecting the UPS to the wall outlet) and the USB communication cable are typically ora klebu and must be purchased separately if needed.
4. Setup
4.1. Mbukak Kemasan lan Sambungan Baterei
- Kasebut kanthi teliti, mbusak UPS saka packaging sawijining.
- Locate the yellow battery connector on the rear panel of the UPS. This connector is typically disconnected for safe transport.
- Push the yellow battery connector firmly into its socket until it clicks into place. This activates the UPS battery circuits.
4.2. Nyambung menyang Daya
- Connect the UPS to a grounded 230V AC wall outlet using an appropriate IEC-320 C14 input power cable (not included).
- Ensure the connection is direct to the wall outlet. Do not use surge protectors or extension cords.
- Allow the UPS to charge for at least 10 hours before connecting critical equipment to ensure full battery runtime.
4.3. Piranti Nyambung
The BX1400UI features six IEC 320 C13 outlets for connecting your devices.
- Battery Backup & Surge Protection Outlets: All six IEC-C13 outlets provide both battery backup and surge protection. Connect your computer, monitor, and other critical electronics to these outlets.
- Proteksi Jalur Data: The rear panel includes RJ-11 ports labeled "DSL/Modem/Fax/Phone" for protecting your telephone or DSL line from surges. These ports are not suitable for Ethernet network connections.
- Antarmuka USB: Connect a USB Type B cable (not included) from the UPS to your computer for communication and to enable shutdown software functionality.

Figure 2: Rear panel connections of the APC Back-UPS BX1400UI.
5. Instruksi Operasi
5.1. Powering On / Off
- Kanggo Power On: Press and hold the power button on the front panel until you hear a short beep. The UPS will perform a self-test, and the 'On Line' LED will illuminate green.
- Kanggo mateni: Pencet terus tombol daya nganti UPS mati.
5.2. Indikator LED
The front panel features LED indicators to show the UPS status:
- Online (LED Ijo): Indicates the UPS is operating on utility power and providing power to connected equipment.
- On Battery (Yellow LED): Indicates the UPS is operating on battery power during a power outage or brownout. A humming noise is normal during battery operation.
- Ganti Batere (LED Abang): Indicates the battery needs to be replaced.
- Kelebihan Beban (LED Abang): Indicates that the connected equipment exceeds the UPS's capacity. Disconnect non-essential equipment immediately.
5.3. Otomatis Voltage Peraturan (AVR)
UPS kanthi otomatis mbenerake voltase minortage fluctuations (sags and surges) without switching to battery power, thus preserving battery life. If voltage fluctuations exceed the AVR's correction range, the UPS will switch to battery power.
6. Fitur Utama
- Teknologi Interaktif Garis: Provides stable power by regulating voltage without constantly switching to battery.
- Vol Otomatistage Regulasi (AVR): Corrects minor voltage fluctuations without using battery power.
- Gawe serep baterei: Supplies power to connected equipment during outages.
- Proteksi Surge: Protects connected devices from damaging power surges and spikes.
- 6 IEC 320 C13 Outlets: Standard outlets for computer equipment.
- Antarmuka USB: Enables communication with a computer for monitoring and controlled shutdown.
- Proteksi Jalur Data: Safeguards telephone/DSL lines from surges.
7. Panggunaan piranti lunak
The APC Back-UPS BX1400UI supports USB Human Interface Device (HID) class specifications, allowing it to be recognized by most operating systems without special drivers.
7.1. APC PowerChute Personal Edition (Windows)
For advanced monitoring and management on Windows systems, download the APC PowerChute Personal Edition software from the official APC websitus. Piranti lunak iki ngidini sampeyan:
- Monitor UPS status, power consumption, and battery charge.
- Konfigurasi mati otomatis komputer sajrone daya luwih akehtages.
- Adjust UPS settings, such as alarm behavior (e.g., disable the beeper during battery operation).
- Perform self-tests to ensure proper UPS functionality.
7.2. Linux Support (apcupsd / NUT)
For Linux environments, the UPS can be managed using `apcupsd` or Network UPS Tools (NUT). These tools provide similar monitoring and shutdown capabilities. Refer to the documentation for `apcupsd` or NUT for configuration details, typically involving specifying `UPSCABLE usb` and `UPSTYPE usb` for `apcupsd`, or using the `usbhid-ups` driver for NUT.
8. Pangopènan
8.1. Panggantos baterei
The APC Back-UPS BX1400UI uses two 12V 7.2Ah sealed lead-acid batteries. The recommended replacement battery pack is APC RBC113.
- During Warranty: If the unit is still under its 2-year warranty, battery replacement must be performed by Schneider Electric IT (SEIT) customer service. User-performed battery replacement during the warranty period will automatically void the warranty.
- After Warranty: After the warranty period, batteries can be replaced by the user. However, due to the presence of high voltage components even when disconnected, it is highly recommended that this operation be performed by specialized personnel. If you choose to replace the batteries yourself, exercise extreme caution.
- Prosedur liwatview (for experienced users only): Disconnect the UPS from all power sources and connected equipment. Disconnect the yellow battery connector. Remove the rear panel screws, then the front panel (which is snap-fitted), and additional screws. Carefully access the battery compartment. Note the orientation and wiring of the existing batteries (taking photos is recommended) to ensure correct installation of the new batteries.
8.2. Circuit Breaker Reset
In case of an overload, the UPS may trip its circuit breaker. To reset, disconnect some equipment from the UPS, then press the circuit breaker button located on the rear panel (refer to Figure 2).
9. Ngatasi masalah
| Masalah | Kemungkinan Penyebab | Solusi |
|---|---|---|
| UPS ora urip. | Battery connector disconnected; No input power. | Ensure yellow battery connector is fully inserted. Verify UPS is plugged into a live wall outlet. |
| Initial strong odor. | New unit manufacturing residue. | This is normal. Ensure adequate ventilation. Odor will dissipate over time (typically a few weeks). |
| UPS emits a humming noise. | Operating on battery power; Normal electrical noise. | Humming is normal when on battery. If persistent and loud on utility power, ensure proper ventilation and check for loose connections. |
| 'Overload' LED is lit. | Piranti sing disambungake kakehan. | Disconnect non-essential equipment. Press the circuit breaker reset button on the rear panel. |
| 'Replace Battery' LED is lit. | Baterei cedhak pungkasan urip. | Contact APC support or a qualified technician for battery replacement. Refer to Section 8.1. |
| Runtime baterei cendhak. | Battery not fully charged; Battery nearing end of life; Excessive load. | Ensure initial 10-hour charge. Reduce connected load. Consider battery replacement if old. |
For more detailed troubleshooting, refer to the complete user manual available on the APC websitus.
10. Spesifikasi
| Fitur | Spesifikasi |
|---|---|
| Model | BX1400UI |
| Kapasitas (VA/Watt) | 1400 VA / 700 W |
| Vol inputtage | 230 V AC |
| Frekuensi Input | 50 Hz |
| Output Voltage | 230V AC (simulated sine wave on battery) |
| Outlet Output | 6 x IEC 320 C13 (Battery Backup & Surge Protection) |
| Rating Proteksi Surge | 273 jl |
| Jinis baterei | Asam timbal sing disegel |
| Konfigurasi baterei | 2 x 12V 7.2Ah |
| Wektu Isi Ulang Khas | 8 hours (to 90% capacity) |
| Runtime (at 700W load) | Kurang luwih 1 menit |
| Runtime (at 100W load) | Kira-kira 60 menit |
| Ukuran (L x W x H) | 21.5 cm x 13 cm x 33.6 cm |
| Bobot | 4.7 kg |
| Pelabuhan Antarmuka | USB Type B, RJ-11 (Data Line Protection) |

Figure 3: Typical runtime graph for APC Back-UPS 1400VA.
11. Warranty lan Dhukungan
11.1. Garansi Produk
The APC Back-UPS BX1400UI comes with a 2-taun babar pisan winates saka tanggal tuku. Garansi iki nyakup cacat ing bahan lan pengerjaan ing panggunaan normal. Mangga nyimpen bukti tuku kanggo claims babar pisan.
penting: Unauthorized opening of the unit or user-performed battery replacement during the warranty period will void the warranty.
11.2. Dhukungan Teknis
For technical assistance, troubleshooting, or warranty service, please contact APC by Schneider Electric customer support. Visit the official APC website for contact information specific to your region, including phone numbers and online support resources.
Online resources often include FAQs, knowledge bases, and downloadable manuals that can provide further assistance.