1. Produk Liwatview

The Metrel A 1316 is a 3-phase test cable adapter designed for use with various Metrel electrical testing devices. This adapter facilitates the connection of 3-phase electrical systems to compatible test equipment, enabling accurate and safe measurements. It is built to ensure reliable performance in professional testing environments.

Metrel A 1316 3-Phase Test Cable Adapter with a red CEE plug and a standard European plug

Figure 1: Metrel A 1316 3-Phase Test Cable Adapter. This image displays the adapter, featuring a coiled black cable connecting a red CEE 16A 5-pin plug on one end and a standard European Type F (Schuko) plug on the other.

2. Kompatibilitas

The Metrel A 1316 3-Phase Test Cable Adapter is compatible with the following Metrel testing instruments:

  • MI 3321
  • MI 3310
  • MI 3304
  • MI 3305
  • MI 3308
  • MI 3307
  • MI 3309
  • MI 3311
  • MI 2170

Ensure your Metrel device is listed above for proper functionality and safety.

3. Spesifikasi

AtributNilai
MerkMetrel
Nomer Model20991678
Jinis3-Phase Test Cable Adapter (16 A CEE)
dhuwur70 mm
Jembar180 mm
ambane230 mm
Bobot464 g (product only), 520 g (with packaging)
KalibrasiFactory calibration without certificate

4. Setup

Follow these steps to properly set up the Metrel A 1316 adapter with your compatible testing device:

  1. Priksa adaptor: Before each use, visually inspect the adapter cable and connectors for any signs of damage, wear, or exposed wires. Do not use if any damage is observed.
  2. Connect to Testing Device: Connect the appropriate end of the A 1316 adapter to the input port of your Metrel testing instrument. Ensure a secure and firm connection. Refer to your specific Metrel instrument's manual for exact port locations.
  3. Connect to 3-Phase Supply: Plug the 3-phase CEE 16A connector of the A 1316 adapter into the 3-phase electrical supply outlet you intend to test. Ensure the outlet is correctly wired and rated for 16A.
  4. Connect to Appliance (if applicable): If testing a 3-phase appliance, connect the appliance's power cord to the corresponding outlet on the A 1316 adapter.
  5. Verifikasi sambungan: Double-check all connections to ensure they are tight and correctly seated before proceeding with any measurements.

Safety Note: Always ensure the power supply is de-energized before making or breaking connections to prevent electrical shock or damage to equipment. Follow all local electrical safety regulations and guidelines.

5. Ngoperasikake

Once the Metrel A 1316 adapter is correctly set up, you can proceed with your electrical measurements using your compatible Metrel testing device. The adapter acts as a bridge, allowing the testing instrument to interface with 3-phase electrical systems.

  • Daya On: Turn on your Metrel testing instrument.
  • Select Test Function: Choose the desired test function on your Metrel instrument (e.g., insulation resistance, loop impedance, RCD test) according to the specific measurement required.
  • Miwiti Tes: Follow the instructions on your Metrel instrument to initiate the test. The adapter will facilitate the connection to the 3-phase circuit.
  • Waca asil: Observe and record the test results displayed on your Metrel instrument.
  • Putus sambungan kanthi aman: After completing all tests, ensure the power supply is de-energized before disconnecting the adapter from the 3-phase supply and then from the testing instrument.

Caution: Never attempt to test live circuits without proper training and safety precautions. Always wear appropriate personal protective equipment (PPE).

6. Pangopènan

Proper maintenance ensures the longevity and accuracy of your Metrel A 1316 adapter.

  • Reresik: Clean the adapter regularly with a soft, dry cloth. Do not use abrasive cleaners or solvents, as these can damage the cable insulation or connectors.
  • Panyimpenan: Store the adapter in a clean, dry place, away from direct sunlight and extreme temperatures. Coil the cable loosely to prevent kinks or damage.
  • Pemriksaan: Periodically inspect the cable and connectors for any signs of wear, cuts, cracks, or corrosion. Replace the adapter if any damage is found.
  • Kalibrasi: The adapter is supplied with factory calibration without a certificate. For applications requiring certified calibration, consult Metrel or an authorized service center.

7. Ngatasi masalah

If you encounter issues while using the Metrel A 1316 adapter, consider the following:

  • No Connection/Reading:
    • Priksa manawa kabeh sambungan aman lan dipasang kanthi lengkap.
    • Verify that the 3-phase power supply is active.
    • Check if the Metrel testing instrument is powered on and functioning correctly.
    • Inspect the adapter cable for visible damage.
  • Wacan sing ora akurat:
    • Confirm that the adapter is compatible with your specific Metrel testing instrument (refer to Section 2).
    • Ensure the testing instrument's settings are appropriate for the measurement being taken.
    • Consider if the adapter or testing instrument requires recalibration.
  • Kerusakan fisik:
    • If the adapter shows signs of physical damage (e.g., cuts, cracks, bent pins), discontinue use immediately and replace it.

For persistent issues, contact Metrel customer support or an authorized service center.

8. Warranty lan Dhukungan

Information regarding specific warranty terms for the Metrel A 1316 adapter is typically provided with the product packaging or can be found on the official Metrel website. Generally, Metrel products come with a manufacturer's warranty covering defects in materials and workmanship.

For technical support, service, or warranty claims, please contact Metrel customer service or your local authorized Metrel distributor. Provide your product model number (A 1316) and serial number (if applicable) when seeking support.

Metrel Official Websitus: www.metrel.si

© 2023 Metrel. All rights reserved. This manual is for informational purposes only.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.